Everpure EV979902

Everpure EV9799-02 SS-10 ScaleStick Replacement Instruction Manual

Gerð: EV979902

1. Vöru lokiðview

The Everpure EV9799-02 SS-10 ScaleStick is a replacement cartridge engineered to inhibit mineral scale deposits and prevent corrosion in various water-fed equipment. It utilizes a specialized Hydroblend compound to provide effective scale prevention.

This cartridge is suitable for use with ice machines, office water dispensers, coffee machines, and espresso machines. For applications where water temperature consistently exceeds 125°F (52°C), the cartridge requires installation within a high-temperature housing.

The translucent design of the cartridge allows for visual monitoring of the Hydroblend compound's depletion, indicating when a replacement is necessary.

Everpure EV9799-02 SS-10 ScaleStick Replacement Cartridge

Image of the Everpure EV9799-02 SS-10 ScaleStick replacement cartridge, showing its translucent body and compact design.

2. Uppsetning og uppsetning

The SS-10 ScaleStick cartridge is designed to fit most standard 10-inch filter housings, including Everpure's current SR-X housings and all existing AR-X housings (old style).

Uppsetningarskref:

  1. Slökktu á vatnsveitunni: Locate the main water shut-off valve for the equipment or system where the ScaleStick will be installed and turn it off.
  2. Þrýstijafnari kerfi: Open a nearby faucet or valve to release any residual water pressure in the system.
  3. Opið síuhús: Carefully unscrew or unclamp the existing filter housing. Be prepared for some water spillage.
  4. Fjarlægðu gamla rörlykjuna: Remove the old ScaleStick or filter cartridge from the housing. Dispose of it properly, ideally at a recycling facility for Everpure filters.
  5. Hreint húsnæði: Inspect and clean the inside of the filter housing, including the O-rings. Replace O-rings if they appear worn or damaged.
  6. Settu inn nýjan blekhylki: Place the new Everpure EV9799-02 SS-10 ScaleStick cartridge into the housing, ensuring it is seated correctly.
  7. Loka síuhúsi: Carefully screw or clamp the housing back together. Hand-tighten only; do not overtighten.
  8. Endurheimta vatnsveitu: Slowly turn on the main water supply valve.
  9. Athugaðu fyrir leka: Monitor the housing for any signs of leaks. If leaks occur, turn off the water, depressurize, and re-seat the cartridge or check O-rings.
  10. Skolakerfi: Allow water to run through the system for several minutes to flush out any air or loose particles before using the treated water.

3. Notkunarleiðbeiningar

The Everpure EV9799-02 SS-10 ScaleStick operates passively once installed. The Hydroblend compound is automatically dispensed into the water flow at a controlled rate, providing continuous scale inhibition and corrosion prevention.

No manual adjustments or user interaction are required during the operational life of the cartridge.

4. Viðhald

Skipt um skothylki:

  • The SS-10 ScaleStick has an approximate capacity of six months.
  • Monitor the translucent cartridge visually for depletion of the Hydroblend compound. Replace the cartridge when the compound is visibly low or depleted, or at least every six months, whichever comes first.
  • Follow the installation steps outlined in Section 2 for replacing the cartridge.

Förgun:

  • Dirty Everpure filters and ScaleSticks should be recycled at your nearest designated drop-off location. Consult local recycling guidelines for proper disposal.

5. Bilanagreining

  • Minnkuð vatnsrennsli: If you experience a noticeable decrease in water flow, first ensure that the cartridge is properly seated within the housing. Check for any potential clogs in pre-filters if your system includes them.
  • Persistent Scale Formation: If scale formation continues despite using the ScaleStick, verify that the cartridge was installed correctly and that it has not exceeded its operational life. Ensure the water temperature is within the recommended range or that a high-temperature housing is used if necessary.
  • Leki úr húsnæði: If water leaks from the filter housing, turn off the water supply immediately. Depressurize the system, open the housing, and inspect the O-rings for damage or improper seating. Replace damaged O-rings and ensure the housing is securely, but not overtightened, closed.

6. Tæknilýsing

GerðarnúmerEV979902
Mál (L x D)10.06" x 1.31" (25.55 cm x 3.33 cm)
GetuApproximately Six Months
Rennslishraði0.1 - 6 gallons per minute (0.38 - 22.7 liters per minute)
Hámarkshiti150°F (65.5°C)
EfniPólýprópýlen (PP)
Þyngd hlutar0.35 pund (0.16 kg)

7. Upplýsingar um ábyrgð

Everpure products are manufactured to high-quality standards. For specific warranty details regarding the EV9799-02 SS-10 ScaleStick, please refer to the warranty documentation provided with your original purchase or visit the official Everpure webGeymið kaupkvittunina ef þið viljið gera kröfur um ábyrgð.

8. Þjónustudeild

For technical assistance, replacement parts, or further inquiries regarding your Everpure EV9799-02 SS-10 ScaleStick, please contact Everpure customer support. Contact information can typically be found on the Everpure official websíðunni eða á umbúðum vörunnar.