NOYAFA NF-909

Noyafa NF-909C Fiber Optic Tester User Manual

Model: NF-909C | Brand: NOYAFA

1. Inngangur

The Noyafa NF-909C is a compact and easy-to-use 2-in-1 testing instrument designed for optical fiber networks. It integrates both an optical power meter and an optical light source, making it suitable for absolute optical power measurements and insertion loss tests. This device offers a wide range of power measurement, high accuracy, and stable output, providing a cost-effective solution for fiber optic testing.

2. Öryggisupplýsingar

  • Lestu handbókina: Before operating the device, thoroughly read and understand this user manual.
  • Öryggi rafhlöðu: Use only specified 1.5V batteries (3x AAA). Do not mix old and new batteries or different types of batteries. Remove batteries if the device will not be used for an extended period.
  • Laser öryggi: The optical light source emits laser radiation. EKKI look directly into the optical output port or into a fiber connected to the light source. Direct exposure to laser light can cause severe eye damage.
  • Umhverfisskilyrði: Operate the device within the specified operating temperature range (-10°C to +60°C). Avoid exposure to extreme temperatures, humidity, or dust.
  • Þrif: Keep optical connectors clean. Use only approved cleaning methods and materials to avoid damaging the fiber end-faces.
  • Viðhald: Ekki reyna að opna eða gera við tækið. Látið hæft starfsfólk sjá um alla þjónustu.

3. Innihald pakka

Gakktu úr skugga um að allir hlutir séu til staðar og í góðu ástandi við upppakkningu:

  • Noyafa NF-909C Fiber Optic Tester Unit
  • Notendahandbók
  • Protective Cap for Optical Ports
  • (Batteries may or may not be included depending on the retailer)

4. Vöru lokiðview

The NF-909C features a clear LCD display, intuitive control buttons, and standard optical connectors for versatile use.

Noyafa NF-909C Fiber Optic Tester front view with display, buttons, and optical ports

Mynd 1: Framan view of the Noyafa NF-909C Fiber Optic Tester. This image shows the device's display screen, the red control buttons (Power, REF, dBm/W, λ, Hz), and the two optical input/output ports on the front, protected by a red cap. The device is black and red.

Noyafa NF-909C Fiber Optic Tester side view showing micro USB port

Mynd 2: Hlið view of the Noyafa NF-909C Fiber Optic Tester. This image highlights the micro USB port located on the side of the device, which may be used for power or data transfer, though its primary function is typically for charging or external power supply. The red protective cap is shown detached.

Lykilhlutir:

  • LCD skjár: Shows measurement readings, selected wavelength, unit, and battery status.
  • Stjórnhnappar: Power On/Off, Reference (REF), Unit (dBm/W), Wavelength (λ), Frequency (Hz).
  • Optical Power Meter Input: Typically supports SC, ST, LC connectors (optional).
  • Optical Light Source Output: Typically FC connector (SC, ST, LC optional).
  • Rafhlöðuhólf: Located on the rear, for 3x 1.5V batteries.
  • Micro USB tengi: For power supply or charging (refer to Figure 2).

5. Uppsetning

5.1 Uppsetning rafhlöðu

  1. Finndu rafhlöðulokið aftan á tækinu.
  2. Renndu eða losaðu lokið til að opna það.
  3. Insert three (3) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Settu hlífina á rafhlöðuhólfinu á öruggan hátt.

5.2 Byrjunarkveikt

Ýttu á og haltu inni Kraftur button to turn on the device. The LCD display will illuminate, showing the current mode and settings.

6. Notkunarleiðbeiningar

6.1 Optical Power Meter Mode

This mode measures the absolute optical power or relative loss in optical fiber networks.

  1. Tengdu ljósleiðara: Connect the optical fiber to be tested to the Power Meter input port. Ensure the connector is clean.
  2. Veldu bylgjulengd: Ýttu á λ button to cycle through the available calibrated wavelengths: 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm. Select the wavelength matching your light source.
  3. View Mæling: The display will show the optical power in dBm.
  4. Change Unit: Ýttu á dBm/W button to switch between dBm and W (Watts) units.
  5. Set Reference (REF): For relative measurements (loss), connect a known good fiber to a stable light source and the power meter. Press the REF button to set the current power reading as the reference (0dB). Subsequent measurements will show the loss relative to this reference.
  6. Frequency Identification: The power meter can identify modulation frequencies from 10Hz to 60KHz. If the incoming signal is modulated, the frequency will be displayed.

6.2 Optical Light Source Mode

This mode provides a stable optical signal for testing fiber optic cables.

  1. Tengdu ljósleiðara: Connect the optical fiber to be tested to the Light Source output port. Ensure the connector is clean.
  2. Veldu bylgjulengd: Ýttu á λ button to cycle through the available wavelengths: 1310nm and 1550nm. Select the desired wavelength.
  3. Select Modulation Frequency: Ýttu á Hz button to cycle through modulation frequencies: 270Hz, 1KHz, 2KHz, or continuous wave (CW).
  4. Úttaksmerki: The device will emit a stable optical signal at the selected wavelength and modulation.

6.3 Sjálfvirk slökkviaðgerð

The device features an auto-off function to conserve battery life. If no operation is performed for approximately 15 minutes, the device will automatically power off. Press the Kraftur hnappinn til að kveikja aftur á henni.

7. Viðhald

  • Cleaning Optical Connectors: Always ensure optical connectors are clean before use. Use lint-free wipes and appropriate optical cleaning solutions. Dirty connectors can lead to inaccurate measurements and damage to the device or fiber.
  • Skipt um rafhlöðu: When the battery indicator on the display shows low power, replace all three 1.5V AAA batteries promptly.
  • Geymsla: When not in use, store the device in a dry, cool place, away from direct sunlight and extreme temperatures. Always replace the protective caps on the optical ports to prevent dust and damage.
  • Ytri þrif: Hreinsaðu ytra byrði tækisins með mjúku, damp klút. Ekki nota slípiefni eða leysiefni.

8. Bilanagreining

  • Tækið kveikir ekki á sér:
    • Athugið hvort rafhlöðurnar séu rétt settar í með réttri pólun.
    • Skiptu um með nýjum rafhlöðum.
  • Inaccurate power meter readings:
    • Ensure optical connectors are clean.
    • Verify the selected wavelength on the power meter matches the light source wavelength.
    • Check if the fiber under test is properly connected and not damaged.
  • No light output from light source:
    • Ensure the device is powered on and in light source mode.
    • Athugaðu stöðu rafhlöðunnar.
    • Verify the fiber is properly connected to the output port.
  • Auto-off activates too quickly:
    • The auto-off is fixed at 15 minutes of inactivity. This is normal operation.

9. Tæknilýsing

EiginleikiForskrift
Optical Power Meter Module
Detector Measurement Range-50 ~ +26 dBm
Calibrated Wavelengths850, 1300, 1310, 1490, 1550, 1625 nm
Upplausn0.01 dBm
Identification Frequency Range10 Hz ~ 60 KHz
Optískt tengiSC, ST, LC (optional)
Optical Light Source Module
Emitter Wavelengths1310 / 1550 nm (other wavelengths customizable)
Output Power-7 dBm
Framleiðslustöðugleiki0.05 dB / 15 mins; 0.1 dB / 8 hours
Modulation Frequencies270 Hz, 1 KHz, 2 KHz
Optískt tengiFC (SC, ST, LC optional)
Almennar upplýsingar
Aflgjafi3 x 1.5V AAA rafhlöður
Sjálfvirk slökkvitími15 mínútur (um það bil)
Rekstrarhitastig-10°C ~ +60°C
Mál (L x B x H)160 x 75 x 32 mm
Þyngd400 g (unit only) / 150 g (item weight from specs)
Lágmarksstarfsmagntage1.5 volt
Hámarksrekstur Voltage5 volt
Lýsing uppfylltUL 61010-1, IEC 61010-2-030
FramleiðandiShenzhen Noyafa Electronic

10. Ábyrgð og stuðningur

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your authorized Noyafa dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase.