PowMr SL03-30A
PowMr SL03-30A Solar Charge Controller User Manual
Model: SL03-30A
1. Inngangur
The PowMr SL03-30A Solar Charge Controller is designed to manage the power flow from your solar panels to your battery bank, ensuring efficient charging and protecting your batteries from overcharge and over-discharge. This controller is suitable for 12V/24V systems and supports various battery types including Lithium and Lead-Acid batteries. It features an LCD display for monitoring system parameters and offers multiple protection functions to enhance system safety and longevity.
2. Helstu eiginleikar

Mynd: Yfirview of the PowMr SL03-30A Solar Charge Controller's main features, including 12V/24V auto-detection, energy recording, temperature compensation, aluminum heat sink, eight electronic protections, compatibility with Lithium/Lead-acid batteries, and light & timer control.
- 12V/24V Auto-detection: Automatically identifies system voltage.
- Energy Recording/Current Display: Provides real-time monitoring of energy and current.
- Hitabætur: Adjusts charging parameters based on ambient temperature.
- Hitavaskur úr áli: Ensures efficient heat dissipation for stable operation.
- Eight Electronic Protections: Comprehensive safety features including overcharge, over-discharge, short-circuit, and reverse current protection.
- Samhæfni rafhlöðu: Supports Lithium and Lead-Acid battery types (Flooded, GEL, AGM, LiFePO4).
- Light & Timer Control: Programmable load control functions.
- LCD skjár: Clear interface for parameter viewog aðlögun.

Mynd: Innra view of the controller highlighting key components such as the copper coil for stable charge/discharge, a fuse for double protection, and MOSFETs made from good raw materials for current sensing.
3. Öryggisleiðbeiningar
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the controller, battery, or solar panels, and may void the warranty.
- Ensure the battery is connected first to allow the controller to recognize the system voltage.
- Always connect the solar panels and load after the battery.
- Disconnect the solar panels and load before disconnecting the battery.
- Install the controller in a well-ventilated, dry, and cool environment, away from flammable materials.
- Avoid touching or short-circuiting wires or terminals.
- Notið viðeigandi vírþykkt fyrir allar tengingar til að koma í veg fyrir ofhitnun.
- This device is for indoor use only. Avoid exposure to water or excessive humidity.
- Geymið þar sem börn ná ekki til.
4. Uppsetning
4.1 Rafmagnsröð
- Connect the battery to the charge controller. Ensure correct polarity (+ to + and - to -). The controller will display the battery voltage.
- Connect the solar panel to the charge controller. Ensure correct polarity. The controller will begin charging the battery.
- Connect the load to the charge controller. Ensure correct polarity.
Mikilvægt: Always connect the battery first and disconnect it last. This sequence prevents damage to the controller from voltage bylgjur.
4.2 Uppsetning
Mount the controller vertically on a wall or flat surface in a well-ventilated area, away from direct sunlight, high temperatures, and water. Ensure there is sufficient air circulation around the heat sink.

Image: The PowMr SL03-30A Solar Charge Controller showing its mounting holes on the sides, indicating how it can be affixed to a surface.

Image: A detailed wiring diagram for the solar charge controller, showing connections for PV combiner box, battery bank, DC load, and inverter. It also illustrates the LCD display and various parameters.
4.3 Video Guide: How to Connect the Controller
Video: This video demonstrates the correct wiring procedure for the PowMr SL03-30A Solar Charge Controller, showing how to connect the battery and solar panels. It also shows how to browse the interface and adjust settings.
5. Rekstur
5.1 LCD skjár og hnappar
The controller features an LCD display and three buttons for operation: UP, DOWN, and SET.
- UPP hnappur: Navigates through display interfaces, increases parameter values.
- NIÐUR hnappur: Navigates through display interfaces, decreases parameter values.
- SET hnappur: Enters/exits setting mode, confirms parameter changes.
5.2 Browsing Display Interfaces
Press the UP or DOWN button to cycle through various display interfaces, including battery voltage, charging current, accumulated discharge, and load status.
5.3 Færibreytustillingar
To enter the setting interface, long-press the SET button for 5 seconds. Use the UP and DOWN buttons to adjust values and the SET button to confirm and move to the next parameter. Long-press SET again to save changes and exit.
Stillanlegir breytur eru meðal annars:
- Tegund rafhlöðu: Select the correct battery type (e.g., Lead-Acid, Lithium).
- Hleðslustjórnunarstilling: Set timer for load operation (e.g., 24H for continuous, 16H for dusk-to-dawn).
- Hleðsla Voltage: Adjust maximum charge voltage.
- Losunarlokun Voltage: Stilltu lágmarksmagntage before load disconnection.
- Discharge Reconnect Voltage: Stilltu voltage at which the load reconnects.
Refer to the "Specifications" section for default and adjustable ranges for each parameter.
6. Verndaraðgerðir

Image: A circular diagram illustrating the eight electronic protection features of the PowMr SL03-30A Solar Charge Controller, including power off memory, short-circuit, over-charging, open-circuit, over-load, under-voltage discharge, over-heat, and dual MOSFET reverse current protection.
The PowMr SL03-30A controller incorporates multiple protection mechanisms to ensure the safety and longevity of your solar system:
- Ofhleðsluvörn: Kemur í veg fyrir að rafhlöður skemmist vegna ofhleðslu.
- Ofhleðsluvörn: Disconnects the load when battery voltage fer niður fyrir öruggt mörk.
- Skammhlaupsvörn: Slekkur sjálfkrafa á sér ef skammhlaup verður.
- Open-circuit Protection: Protects the system if the solar panel circuit is open.
- Öfug pólunarvernd: Prevents damage from incorrect battery or solar panel connections.
- Yfirálagsvörn: Disconnects the load if current exceeds the rated limit.
- Yfirhitavörn: Reduces power or shuts down if the controller's internal temperature is too high.
- Slökktu á minni: Varðveitir stillingar jafnvel eftir rafmagnsleysi.
7. Tæknilýsing

Image: A comprehensive table detailing the specifications for PowMr SL03-10A, SL03-20A, SL03-30A, and SL03-40A models, including normal battery voltage, charge/discharge current, battery type, system recognize range, charging regulation, maximum PV open circuit voltage, and various protection parameters.
| Parameter | Value (SL03-30A) |
|---|---|
| Normal Battery Voltage | 12V / 24V farartæki |
| Hleðslustraumur | 30A |
| Losunarstraumur | 30A |
| Tegund rafhlöðu | Lead-Acid Battery (Flooded, AGM, Gel, Calcium), LiFePO4 (Lithium) |
| System Recognize Range | Lead-Acid Battery: 8V-15V(12V System), 18V-30V(24V System) LiFePO4: 8V-15V(12V), 18V-30V(24V) |
| Charging Regulation | Bulk, Absorption, Float, Equalization |
| Hámark PV Open Circuit Voltage (söngur) | <= 50V |
| Max. PV Input Wattage (12V/24V) | 360W/720W |
| Stop-charge Voltage | Default 14.4V (12V), 28.8V (24V) (adjustable) |
| Float-charge Voltage | Default 13.6V (12V), 27.2V (24V) (adjustable) |
| Lágt binditage Reconnected | Default 12.4V (12V), 24.8V (24V) (adjustable) |
| Lágt binditage Aftenging | Default 10.8V (12V), 21.6V (24V) (adjustable) |
| No Load Losses | <10mA |
| Uppbót fyrir hitastig rafhlöðu | Automatic with optional NTC thermal probe (adjustable) |
| Rekstrarhitastig | -20°C til +60°C |
| Outline Size (L*W*H) | 143*77*40mm |
| Festingarholabil | 134*55 mm |
| Þyngd | 260g |
8. Bilanagreining
This section provides solutions to common issues you might encounter with your PowMr SL03-30A Solar Charge Controller.
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| Slökkt er á stýrisskjánum. | Engin rafhlaða tengd eða rafhlöðumagntage of lágt. | Connect the battery correctly. Ensure battery voltage er yfir 8V. |
| "LLL" or "HHH" displayed on screen. | No PV input or PV voltagof lágt/hátt. | Ensure solar panels are connected and receiving sunlight. Check PV voltage. |
| Rafhlaða hleðst ekki. | Sólsella ekki tengd, ófullnægjandi sólarljós eða rangar raflagnir. | Check solar panel connections and ensure adequate sunlight. Verify wiring polarity. |
| Load not working. | Load disconnected, battery voltage too low (over-discharge protection), or load control settings. | Check load connections. Charge battery. Adjust load control timer (e.g., set to 24H for continuous). |
| Controller overheating. | Poor ventilation or excessive load/charging current. | Ensure proper ventilation around the controller. Reduce load or charging current if consistently overheating. |
9. Viðhald
Reglulegt viðhald tryggir bestu mögulegu afköst og lengir líftíma sólarhleðslustýringarinnar.
- Hreinlæti: Haltu stjórntækinu hreinu og lausu við ryk og óhreinindi. Notaðu þurran klút til að þrífa.
- Tengingar: Athugið reglulega hvort allar raflagnir séu þéttar eða tærðar. Lausar tengingar geta valdið ofhitnun og lélegri virkni.
- Loftræsting: Gakktu úr skugga um að loftræstiop séu ekki stífluð til að tryggja rétta varmaleiðni.
- Heilsa rafhlöðu: Fylgstu með rafhlöðu voltage and health regularly. Replace batteries as needed.
- Umhverfisskilyrði: Ensure the controller is operating within its specified temperature and humidity ranges.
10. Ábyrgð og stuðningur
For warranty information, technical support, or service inquiries, please contact PowMr customer service through the retailer where the product was purchased or visit the official PowMr website. Please have your model number (SL03-30A) and purchase date available when contacting support.
Fyrir frekari upplýsingar, heimsækja PowMr Store.
Ask a question about this manual