GOYOJO Z270BCD 2.7

GOYOJO Scuba Diving Ventilator System

Model: Z270BCD 2.7

1. Mikilvægar öryggisupplýsingar

Read all instructions and warnings carefully before using the GOYOJO Scuba Diving Ventilator System. Failure to follow these instructions may result in serious injury or death. This device is intended for recreational diving and snorkeling within specified limits.

  • Þjálfun: Users should be trained and certified in scuba diving or snorkeling techniques appropriate for the intended depth and environment.
  • Depth Limits: Do not exceed the maximum recommended diving depth of 10 meters (33 feet) for this model. Deeper dives can lead to decompression sickness and other serious health risks.
  • Pre-Dive Checks: Always perform a thorough pre-dive check of all equipment components, connections, and battery levels.
  • Buddy System: Always dive with a buddy. Never dive alone.
  • Heilsa: Consult a physician before diving if you have any medical conditions.
  • Neyðaraðgerðir: Be familiar with emergency ascent procedures and how to handle equipment malfunctions underwater.
  • Öryggi rafhlöðu: Use only the provided charger and avoid exposing the battery to extreme temperatures or physical damage.
Illustration showing divers at different depths, indicating safe diving limits for snorkelers (2-3 meters) and experienced divers (7-10 meters) with the GOYOJO system.

Figure 1: Recommended Diving Depth Limits. Novice snorkelers can dive to 2-3 meters, while experienced divers can reach 7-10 meters.

2. Vöru lokiðview og íhlutir

The GOYOJO Scuba Diving Ventilator System is a compact, tankless underwater breathing device designed to supply air from the surface. It consists of a floating air compressor unit, a breathing hose, a regulator, and a Buoyancy Control Device (BCD) vest.

Helstu þættir:

  • Ventilator Unit: The floating surface unit containing the air pump, battery, and controls.
  • Breathing Hose: Connects the ventilator unit to the regulator. This model includes a 10-meter hose.
  • Breathing Regulator: Delivers air to the diver.
  • BCD Buoyancy Vest: Provides buoyancy control underwater.
  • Virkjað kolefnissía: Filters the air before it reaches the diver.
Diagram showing the labeled components of the GOYOJO Scuba Diving Ventilator System, including the ventilator unit, 14m telescopic pipe (hose), straps, activated carbon filter, and respirator (regulator).

Figure 2: System Components. Key parts include the ventilator unit, hose, regulator, and BCD.

Close-up images of the GOYOJO ventilator unit showing its dimensions (42cm x 42cm x 15cm), waterproof switch, battery indicator, and soft latex handle.

Figure 3: Ventilator Unit Details. Features include a waterproof switch, battery indicator, and soft handle for portability.

3. Uppsetning og samsetning

Follow these steps to prepare your GOYOJO Scuba Diving Ventilator System for use.

3.1 Hleðsla rafhlöðunnar

  1. Ensure the ventilator unit is dry before charging.
  2. Connect the charger to the charging port on the ventilator unit.
  3. Stingdu hleðslutækinu í venjulegt rafmagnsinnstungu.
  4. The battery indicator will show charging progress. A full charge for the 40000mAh battery takes approximately 1.5 hours to reach 80% capacity, providing up to 2.7 hours of operation.
  5. Disconnect the charger once fully charged or before use.

3.2 Samsetning kerfisins

  1. Tengja slönguna: Securely attach one end of the breathing hose to the air outlet on the ventilator unit.
  2. Tengdu eftirlitsbúnaðinn: Attach the other end of the breathing hose to the breathing regulator. Ensure all connections are tight to prevent air leaks.
  3. Attach BCD: If using the BCD vest, connect the regulator and hose assembly to the BCD's air inlet. Adjust the BCD straps for a comfortable and secure fit.
  4. Síunarathugun: Verify that the activated carbon filter is correctly installed in the air line.
The complete GOYOJO Scuba Diving Ventilator System laid out, showing the floating ventilator unit, the coiled air hose, the BCD vest, and the breathing regulator.

Figure 4: Fully Assembled System. The ventilator unit, hose, BCD, and regulator are connected.

4. Rekstur

This section details how to operate your GOYOJO Scuba Diving Ventilator System safely and effectively.

4.1 Athuganir fyrir köfun

  • Staðfestu að rafhlaðan sé fullhlaðin.
  • Inspect all hose connections for security and integrity.
  • Check the regulator mouthpiece for any obstructions or damage.
  • Ensure the ventilator unit's air intake is clear and unobstructed.

4.2 Activating the System

  1. Place the ventilator unit on the water surface. It is designed to float.
  2. Press the waterproof power switch on the ventilator unit to turn it on. The power display will illuminate.
  3. Listen for the sound of the air pump activating.

4.3 Underwater Breathing

  • Enter the water with the regulator in your mouth.
  • Breathe normally and calmly. The system will continuously supply air.
  • Monitor your depth and remaining battery life via the indicator on the unit (if visible from the surface or by a buddy).

4.4 Buoyancy Control with BCD

  • The BCD vest allows for individual buoyancy adjustment.
  • Use the inflation valve to add air to the BCD for positive buoyancy (to float).
  • Use the deflate valve to release air from the BCD for negative buoyancy (to sink).
  • Practice buoyancy control in shallow water before attempting deeper dives.

4.5 Post-Dive

  • Upon surfacing, turn off the ventilator unit using the waterproof power switch.
  • Rinse all components with fresh water as soon as possible.

Video 1: Scuba Diving Ventilator System in Use. This video demonstrates the practical application of the GOYOJO diving ventilator system underwater.

5. Viðhald og geymsla

Proper maintenance ensures the longevity and safe operation of your diving system.

5.1 Þrif

  • After each use, thoroughly rinse all components (ventilator unit, hose, regulator, BCD) with fresh, clean water.
  • Pay special attention to the regulator mouthpiece and hose interior.
  • Allow all parts to air dry completely in a shaded, well-ventilated area before storage.
  • Ekki nota sterk efni eða slípiefni.

5.2 Umhirða rafhlöðu

  • Hladdu rafhlöðuna að fullu fyrir langtímageymslu.
  • Recharge the battery every 3-6 months during storage to maintain battery health.
  • Geymið tækið á köldum, þurrum stað, fjarri beinu sólarljósi og miklum hita.

5.3 Síuskipti

  • The activated carbon filter should be inspected regularly and replaced as needed, or after approximately 20 hours of use, to ensure optimal air quality.
  • Refer to the filter replacement instructions provided with replacement filters.

5.4 Geymsla

  • Store the disassembled or carefully coiled system in its original packaging or a protective case.
  • Geymið þar sem börn og gæludýr ná ekki til.

6. Bilanagreining

This section addresses common issues you might encounter with your GOYOJO Scuba Diving Ventilator System.

VandamálMöguleg orsökLausn
No air from regulatorVentilator unit not turned on; Low battery; Hose disconnected or kinked; Regulator malfunction.Ensure unit is on; Charge battery; Check hose connections and for kinks; Inspect regulator for damage.
Unit not floating correctlyImproper placement; Damage to flotation device.Ensure unit is placed flat on the water surface; Inspect for damage and contact support if necessary.
Stuttur notkunartímiRafhlaðan ekki fullhlaðin; Rafhlaðan er að gömul.Ensure battery is fully charged before use; Consider battery replacement if performance degrades significantly.
Water in air inletUnit submerged or splashed excessively.Ensure the unit remains floating on the surface; The unit is designed to prevent water ingress, but excessive submersion should be avoided.

7. Tæknilýsingar

The following specifications apply to the GOYOJO Scuba Diving Ventilator System, Model Z270BCD 2.7 (Ordinary Model).

EiginleikiForskrift
VörumerkiGOYOJO
GerðarnúmerZ270BCD 2.7
Hámarksvinnutími2.7 klst
Rafhlöðugeta40000mAh
Metið VoltageDC 11.1V
Maximum Dive Depth10 metrar
Vöruþyngd6.5 kg (14.33 lbs)
Málkraftur180W
Loftframboð52 lítrar/mín
Mál (L x B x H)40 x 40 x 15 cm (16.53 x 16.53 x 5.9 tommur)
A table showing product parameters for two models, Q1 (Ordinary) and Q2 (Enhanced), detailing working time, electricity, battery capacity, rated voltage, maximum dive depth, product weight, rated power, air supply, and size.

Figure 5: Product Parameter Table. Specifications for the Ordinary (Q1) and Enhanced (Q2) models.

8. Ábyrgð og stuðningur

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact GOYOJO customer service through the retailer where the product was purchased. Keep your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.