1. Inngangur
This manual provides detailed instructions for the assembly, installation, operation, and maintenance of your Tecmojo 18U Wall Mount Server Cabinet and the accompanying 8 Outlet Rack Mount Power Strip. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
2. Öryggisupplýsingar
- Always ensure the cabinet is securely mounted to a structurally sound wall capable of supporting the cabinet's weight plus the weight of all installed equipment.
- Do not exceed the maximum weight capacity of 110 lbs (50 kg) for the cabinet.
- Ensure all electrical connections are made by qualified personnel and comply with local electrical codes.
- Do not block ventilation openings on the cabinet. Proper airflow is essential to prevent overheating.
- Use appropriate personal protective equipment (PPE) during installation, such as gloves and eye protection.
- Haldið börnum og gæludýrum frá uppsetningarsvæðinu.
3. Innihald pakka
Gakktu úr skugga um að allir íhlutir sem taldir eru upp hér að neðan séu til staðar áður en samsetning hefst:
- Neðsta pallborð
- Top Cover (with fans)
- Glerhurð að framan
- Front Frame (2 pieces)
- Rack Rails (4 pieces)
- Side Panels (2 pieces)
- Bakhlið
- Fixed Brackets (4 pieces)
- Cantilever hilla
- L Sviga
- Hjól (4 stykki)
- 8 Outlet Rack Mount Power Strip
- Assorted Screws, Nuts, and Keys
4. Tæknilýsing
4.1. 18U Wall Mount Server Cabinet
- Rekki einingar: 18U
- Efni: Þungt kalt valsað stál
- Þyngdargeta: Allt að 110 lbs (50 kg)
- Stærð (L x D x H): 21.7" x 17.7" x 34.8" (550 mm x 450 mm x 883 mm)
- Gerð festingar: Wall Mount (also supports floor standing with casters)
- Framdyr: Reversible Locking Tempered Glass Door
- Hliðarplötur: Lockable and Removable
- Kæling: One built-in top fan (expandable with additional fan slot), flow-through ventilation
- Kapalstjórnun: Removable top and bottom panels for easy cable routing, knock-off holes
- Fylgni: EIA/ECA-310-E Compliant
4.2. 8 Outlet Rack Mount Power Strip
- Fjöldi útsölustaða: 8 NEMA5-15R
- Inntakstengi: 1 NEMA 5-15P
- Núverandi einkunn: 15A (12A UL Certified)
- Operation Voltage: 125V AC
- Yfirfallsvörn: Já
- LED Vísar: Ground (Green), Surge (Red)
- Rafmagnssnúra: Innbyggður 6 feta rafmagnssnúra
- Uppsetning: 1U Rack-mountable, fits standard 19" server racks
- Rofi: Illuminated ON/OFF switch with protective cover
- Vöruþyngd: 4 pund
- Húsnæði: Kaltvalsað stál
- Vottun: UL vottuð
5. Samsetning og uppsetning
5.1. Server Cabinet Assembly (Floor Standing)
Follow these steps to assemble your server cabinet for floor-standing use. Refer to the provided assembly videos for visual guidance.
- Attach Front Frames to Bottom Panel: Secure the two front frame pieces to the vented side of the bottom panel using the provided screws.
- Secure Back Cover to Bottom Panel: Attach the back cover to the bottom panel using the appropriate screws.
- Setjið efri hlífina á: Position the top cover onto the assembled frame and fasten it with the provided screws. Ensure all accessories are correctly spliced and secured.
- Settu upp rekki: Install the four rack rails uniformly according to your desired equipment depth. Use the provided screws to fix them in place.
- Settu saman hliðarplötur: Attach the left and right side panels in sequence.
- Install Front Glass Door: Align the joints, move the bolt, and install the front glass door. Ensure it opens and closes smoothly.
- Settu upp hjól: Invert the rack, fix the bottom panel, and install the four casters using M6 bolts and nuts.
Video: Tecmojo Standard Wall Mount Cabinet Installation Guide. This video demonstrates the step-by-step assembly of the server cabinet, including attaching frames, panels, and installing casters.
Video: Tecmojo Elite 15/18U Wall Mount Server Cabinet Assembly. This video provides a visual guide for assembling the 15/18U cabinet, showing the installation of various components.
5.2. Server Cabinet Wall Mounted Installation
Ef þú vilt frekar veggfestingu skaltu fylgja þessum skrefum:
- Remove Casters: If casters were installed, remove them.
- Fix Wall Mount Bracket: Secure the wall mount bracket to your desired wall location using appropriate screws and anchors (not included, ensure they are suitable for your wall type and the cabinet's weight). A drilling template is included for easy installation.
- Hang and Secure Cabinet: Carefully hang the assembled cabinet onto the fixed wall mount bracket. Secure the cabinet to the bracket with additional screws.

Image: Wall mounting hole drilling template and key features like removable side panels and knock-off holes for cable management.
5.3. Power Strip Installation
The 8 Outlet Rack Mount Power Strip is designed for seamless integration into standard 19" server racks.
- Tilgreinið festingarstað: Choose a 1U space within your server cabinet for the power strip.
- Secure Power Strip: Align the mounting brackets of the power strip with the rack rails and secure it using appropriate rack screws (typically 10-32 or 12-24, depending on your rack rails).
- Tengdu rafmagn: Plug the integrated 6ft power cord into a suitable wall outlet.

Mynd: Ítarleg view of the 8-Outlet Rack-Mount Power Strip, highlighting its 8 NEMA5-15 outlets and mounting brackets for standard racks.
6. Rekstur
6.1. Server Cabinet Fans
The server cabinet includes one built-in top fan for ventilation. This fan helps to prevent overheating of your network equipment by increasing airflow. Additional fans can be installed in the available slots if needed.
6.2. Power Strip
- Rofi: The power strip features an illuminated ON/OFF switch with a protective cover. Flip the switch to the 'ON' position to supply power to the outlets.
- LED Vísar: The green LED indicates a proper ground connection, while the red LED indicates active surge protection.
6.3. Thermostat (if applicable)
Some models of the Tecmojo Wall Mount Server Cabinet may include a thermostat for fan control. If your model includes this feature, you can set your preferred temperature. The fans will activate automatically when the internal temperature exceeds the set threshold, ensuring optimal cooling.
Video: Wall Mount Server Cabinet with Thermostat. This video demonstrates how to set the thermostat to your preferred temperature for automatic fan control.
7. Viðhald
- Þrif: Regularly clean the exterior of the cabinet with a soft, dry cloth. For the glass door, use a glass cleaner. Ensure no liquids enter the cabinet.
- Viftuskoðun: Periodically check the top fans for dust accumulation. Clean the fan blades gently with a soft brush or compressed air to maintain efficient cooling.
- Kapalstjórnun: Ensure cables are neatly organized and not obstructing airflow or door closure.
- Læsabúnaður: Lubricate the door and side panel lock mechanisms periodically to ensure smooth operation.
8. Bilanagreining
- No Power to Power Strip:
- Check if the power strip's ON/OFF switch is in the 'ON' position.
- Verify the power cord is securely plugged into a working wall outlet.
- Athugaðu rofann fyrir innstunguna.
- Fans Not Operating:
- Ensure the cabinet is receiving power.
- If your model has a thermostat, check its settings to ensure the temperature threshold has been met.
- Inspect fan wiring for any loose connections.
- Equipment Overheating:
- Ensure cabinet fans are operating correctly.
- Check for any obstructions to airflow within the cabinet or at the ventilation openings.
- Consider installing additional fans if the heat load is high.
9. Ábyrgð og stuðningur
Tecmojo products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or contact Tecmojo customer support. Our customer service team is available to assist with any questions or issues you may encounter.
Samskiptaupplýsingar: Please refer to the product packaging or Tecmojo's official websíðu fyrir nýjustu upplýsingar um þjónustuver viðskiptavina.