14POINT7-LOGO

14POINT7 Spartan 3 v2 Lambda stjórnandi

14POINT7-Spartan-3-v2-Lambda-Controller-PRODUCT

Tæknilýsing

  • Vara: Spartan 3 v2
  • Innihald pakka: 1x Spartan 3 v2, 1x USB breytir, 1x Vatnsheldur öryggisblaðhaldari, 2x 5 Amp blaðöryggi

Notkunarleiðbeiningar fyrir vöru

Útblástur uppsetningu
Settu inn 5 amp fuse into the fuse holder, cut the wire at the midpoint, and securely close the lid. Connect one end of the fuse holder to the Spartan 3 red wire and the other end to a switched 12V source, preferably the fuel pump relay.

Raflögn

Vírlitur Nafn
Rauður Kraftur
Svartur Raftækjavöllur

USB fjarskipti
The Spartan 3 comes with a USB converter for communication with a computer. The USB converter uses the FTDI chipset, which is typically preinstalled on most operating systems.

Uppsetning á raðtengi í Windows 10
To communicate with the Spartan 3 via serial commands on Windows 10:

  1. Ensure Electronics Ground (Black), Heater Ground (White), and Power (Red) are connected and the Spartan 3 is powered.
  2. Sæktu og settu upp Termite hugbúnaðinn frá https://www.compuphase.com/software_termite.htm.
  3. In the Windows search bar, type “Device Manager” and open it.
  4. Locate the Spartan 3 USB converter listed as “USB Serial Port” (e.g., COM3).
  5. In Termite, click on Settings, verify the Port is correct (e.g., COM3) and set the Baud rate to 9600.

Raðskipanir

Til að slá inn raðskipanir:

  • Connect Electronics Ground (Black), Heater Ground (White), and Power (Red).
  • Use commands like GETHW, GETFW, SETTYPE, etc., followed by specific values as per the usage note below.

Notkunarathugið
Vísað til meðfylgjandi frvamples to understand how to format and use the serial commands effectively based on the desired settings.

Viðvörun

  • Ekki tengja eða aftengja lambdaskynjarann ​​á meðan Spartan 3 er með rafmagni.
  • Lambdaskynjarinn verður mjög heitur við venjulega notkun, vinsamlegast farðu varlega þegar þú meðhöndlar hann.
  • Ekki setja lambdaskynjarann ​​þannig upp að einingin sé knúin áður en vélin þín er í gangi. Vélarræsing getur fært þéttingu í útblásturskerfinu þínu yfir á skynjarann, ef skynjarinn er þegar upphitaður getur það valdið hitalost og valdið því að innra keramikið inni í skynjaranum sprungur og afmyndast.
  • Á meðan lambdaskynjarinn er í virkum útblástursstraumi verður honum að vera stjórnað af Spartan 3. Kolefni frá virkum útblásturslofti getur auðveldlega safnast upp á kraftlausan skynjara og skaðað hann.
  • Líftími lambdaskynjara þegar hann er notaður með blýeldsneyti er á bilinu 100-500 klst.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-1

Innihald pakka

1x Spartan 3 v2, 1x USB breytir, 1x Vatnsheldur öryggisblaðhaldari, 2x 5 Amp blaðöryggi

Útblástur uppsetningu

Lambdaskynjarinn ætti að vera settur upp á milli klukkan 10 og klukkan 2, minna en 60 gráður frá lóðréttu, þetta mun leyfa þyngdaraflinu að fjarlægja vatnsþéttingu úr skynjaranum.
Fyrir allar uppsetningar fyrir súrefnisskynjara verður að setja skynjarann ​​fyrir hvarfakútinn.

Fyrir hreyfla með venjulega innsog ætti skynjarinn að vera settur upp um það bil 2 fet frá útblástursporti hreyfilsins. Fyrir hreyfla með forþjöppu skal setja skynjarann ​​á eftir forþjöppunni. Fyrir mótor með forþjöppu ætti skynjarinn að vera settur upp 3 fet frá útblástursporti hreyfilsins.

Öryggi

Settu inn 5 amp Setjið öryggið í öryggihaldarann, klippið vírinn í miðjunni og lokið á. Annar endi öryggihaldarans tengist rauða Spartan 3 vírnum, hinn endinn tengist rofa 12[v] spennugjafa, venjulega er mælt með eldsneytisdælu-rofa.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-2

Raflögn

Vírlitur Nafn Tengist Athugið
Rauður Kraftur Skipt 12[v] Use fuse holder, 12[v] should be live only when engine is running. Fuel pump relay is the recommended source.
Svartur Raftækjavöllur Jarðvegur Jörð þar sem tengibúnaður er jarðtengdur
Hvítur Hitari jörð Jarðvegur Jarðað við undirvagn eða vélarblokk
Grænn High Performance Analog

Framleiðsla

Tengitæki;

ECU/Mælir/datalogger/etc…

Default output is linear output; 0[v] @ 0.68 [Lambda] Linear to 5[v] @ 1.36 [Lambda], equivalent to 10-20 [AFR] for gasoline fuel
Brúnn Standard Performance Analog Output Default output is heater status; 0[v] = waiting for trigger before heating sensor, 1[v] = sensor heatup started, 2[v] = sensor heatup complete and sensor heater is in closed loop control
Blár GETUR hátt
Fjólublátt GETUR Lágt
Appelsínugult UART TX “Rx-Orange” on USB converter
Gulur UART RX “Tx-Yellow” on USB converter
Grátt UART Ground “Gnd-Grey” on USB converter

USB fjarskipti

Spartan 3 er með USB-breyti til að tryggja USB-samskipti við tölvuna þína. Breytirinn er byggður á vinsæla FTDI-flísinni þannig að flest stýrikerfi eru þegar með rekla uppsettan.

Windows 10 raðtengi

Electronics Ground (Black), Heater Ground (white), and Power (Red) must be connected and Spartan 3 powered to enter serial commands.
Spartan 3 cannot be powered through USB.

The recommended serial terminal is Termite, https://www.compuphase.com/software_termite.htm, vinsamlegast hlaðið niður og settu upp heildaruppsetninguna.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-3 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-4 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-5 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-6
Í Windows 10 leitarstikunni skaltu slá inn „Device Manager“ og opna hana. Spartan 3 USB converter will show up as “USB Serial Port”, in this examp„COM3“ er úthlutað Spartan 3. Í Termite, smelltu á „Stillingar“ Make sure the Port is correct and that the

Baud rate is “9600”.

Raðskipanir

Jarðtenging rafeindabúnaðar (svartur), jarðtenging hitara (hvítur) og aflgjafi (rauður) verða að vera tengd og Spartan 3 knúinn til að slá inn raðskipanir. Ekki er hægt að knýja Spartan 3 í gegnum USB.

Raðskipun Notkunarathugið Tilgangur Example Sjálfgefið verksmiðju
GETHW Fær vélbúnaðarútgáfu
GETFW Fær vélbúnaðarútgáfu
SETTYPex Ef x er 0 þá er Bosch LSU 4.9

Ef x er 1 þá er Bosch LSU ADV

Stillir gerð LSU skynjara SETTYPE1 x=0, LSU 4.9
GETTYPE Fær LSU skynjara gerð
SETCANFORMATx x er heil tala 1 til 3 stafa löng. x=0; sjálfgefið

x=1; Link ECU

x=2; Adaptronic ECU x=3; Haltech ECU x=4; % Oxygen*100

x=5; Extended CAN format

SETCANFORMAT0 x=0
GETCANFORMAT Fær CAN snið
SETCANIDx x er heil tala 1 til 4 stafir að lengd Stillir 11 bita CAN auðkenni SETCANID1024

SETCANID128

x=1024
GETCANID Fær 11 bita CAN auðkenni
SETCANBAUDx x er heil tala 1 til 7 stafir að lengd Stillir CAN Baud Rate SETCANBAUD1000000

mun stilla CAN Baud hlutfall

í 1Mbit/s

X=500000,

500kbit / s

GETCANBAUD Fær CAN Baud Rate
SETCANRx Ef x er 1 er viðnámið virkt. Ef x er 0 þá

viðnám er óvirkt

Virkja/slökkva á CAN

Uppsagnarviðnám

SETCANR1

SETCANR0

x=1, CAN term Res

Virkt

GETCANR Fær CAN Term Res State;

1=virkt, 0=óvirkt

SETAFRMxx.x xx.x er aukastaf nákvæmlega 4 stafir að lengd

þar á meðal aukastaf

Sets AFR Multiplier for Torque

app

SETAFM14.7

SETAFM1.00

xx.x=14.7
GETAFRM Gets AFR Multiplier for Torque

app

SETLAMFIVEVx.xx x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be

higher or lower than the SETLAMZEROV value.

Stillir Lambda á 5[v] fyrir línulega úttakið SETLAMFIVEV1.36 x.xx=1.36
GETLAMFIVEV Fær Lambda á 5[v]
SETLAMZEROVx.xx x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be

higher or lower than the SETLAMFIVEV value.

Stillir Lambda á 0[v] fyrir línulega úttakið SETLAMZEROV0.68 x.xx=0.68
GETLAMZEROV Fær Lambda á 0[v]
SETPERFx If x is 0 then standard performance of 20ms. If x is 1 then high performance of 10ms. If x is 2

then optimize for lean operation.

SETPERF1 x=1, high performance
GETPERFx Fær frammistöðu
SETSLOWHEATx Ef x er 0 þá er skynjari hituð á eðlilegum hraða við upphaflega ræsingu.

Ef x er 1 þá er skynjari hituð við 1/3 af eðlilegum hraða við upphaflega virkjun.

If x is 2 then wait, a max of 10 min, for MS3 CAN RPM signal before heating.

If x is 3 then wait, a max of 10 min, for exhaust gas to heat sensor to 350C before heating.

Krefst fastbúnaðar 1.05 og nýrri

SETJA HEIT1 x=0, normal sensor heatup rate
HÆGT HEITI Fær hægan hita stillingu
MEMRESET Endurstilla í verksmiðjustillingar.
SETLINOUTx.xxx Where x.xxx is a decimal exactly 5 characters long including decimal point, greater than 0.000 and less than 5.000. Linear Output will resume

normal operation on reboot.

Leyfir notandanum að stilla High Perf Linear Output á tiltekið magntage SETLINOUT2.500
DOCAL Pull sensor out of the exhaust. Power on wideband controller with sensor connected for about 5 minutes then issue the DOCAL command. Do Free Air Calibration and display the value. A perfect sensor will have a value of 1.00. Recommended for clone

nema skynjara.

GETCAL Krefst fastbúnaðar 1.04 og nýrri Fær ókeypis loftkvörðunargildi
RESETCAL Krefst fastbúnaðar 1.04 og nýrri Endurstillir ókeypis loftkvörðun

verðmæti 1.00

SETCANDRx x er heiltala sem er 1 til 4 stafir að lengd. Krefst vélbúnaðar 1.04 og nýrri. Stillir CAN Data Rate í hz For optimal performance, CAN Data

Rate should be 200hz

x=50
GETCANDR Krefst fastbúnaðar 1.04 og nýrri Fær CAN Data Rate
SETNBMODEx If x is 0 then Standard Performance Analog Output is Simulated Narrowband.

Ef x er 2 þá er staðlað afköst hliðrænt

Úttak er staða hitara

Selects the function of the Standard Performance Analog Output between Simulated

Staða þröngbands og hitara

SETNBMODE0 x=2, Heater Status
GETNBMODE Fær staðlaða afköst

Analog útgangsstilling

SETNBSWLAMx.xxx x.xxx is a decimal exactly 5 characters long including decimal point. Requires Firmware

1.08 og ofar

Sets the Simulated Narrowband Switch Point in Lambda SETNBSWLAM1.005 x.xxx=1.000
GETNBSWLAM Fær herma Narrowband

skiptipunktur í Lambda

*Allar skipanir eru í ASCII, lág- og lágstafir skipta ekki máli, bil skipta ekki máli.

CAN Bus Protocol Sjálfgefið snið (Lambda)

Fyrir %O2 CAN snið vinsamlegast sjá “Spartan 3 og Spartan 3 Lite fyrir maga brennslu og súrefnismælingarforrit.pdf” CAN Bus Spartan 3 starfar með 11 bita vistföng.

  • Sjálfgefinn CAN Baud hraði er 500kbit/s
  • Sjálfgefin CAN stöðvunarviðnám er virkt, þessu er hægt að breyta með því að senda „SETCANRx“ raðskipun.
  • Sjálfgefið CAN auðkenni er 1024, þessu er hægt að breyta með því að senda „SETCANIDx“ raðskipun.
  • Gagnalengd (DLC) er 4.
  • Default Data Rate is 50 hz, data is sent every 20[ms], this can be changed by sending “SETCANDRx” serial command. Big-endian for all data
  • Gögn[0] = Lambda x1000 High Byte
  • Gögn[1] = Lambda x1000 Low Byte
  • Gögn[2] = LSU_Temp/10
    Gögn[3] = Staða
  • Lambda = (Gögn[0]<<8 + Gögn[1])/1000
  • Hitastig skynjara [C] = Gögn[2]*10

Staða

Status Value (decimal) Merking
0 Frátekið
1 Waiting for trigger before heating up
2 Sensor is heating up
3 Sensor in normal operation
4+ Frátekið

Supported CAN Formats

CAN Format Name CAN Format Serial

Skipun

CAN Id Serial

Skipun

CAN BAUD Rate Serial

Skipun

Athugið
Link ECU CAN Format SETCANFORMAT1 SETCANID950 SETCANBAUD1000000 Read “Link G4+ ECU CAN Bus Configuration

for Spartan 3.pdf”

Adaptronic ECU CAN

Snið

SETCANFORMAT2 SETCANID1024

(Sjálfgefið frá verksmiðju)

SETCANBAUD1000000
MegaSquirt 3 ECU

CAN snið

SETCANFORMAT0

(Sjálfgefið frá verksmiðju)

SETCANID1024

(Sjálfgefið frá verksmiðju)

SETCANBAUD500000

(Sjálfgefið frá verksmiðju)

Read “Interfacing Spartan 3 to MegaSquirt

3.pdf“

Haltech ECU CAN

Snið

SETCANFORMAT3 Ekki krafist SETCANBAUD1000000 Spartan 3 líkir eftir Haltech WBC1

breiðbandsstýring

YourDyno Dyno

Controller CAN Format

SETCANFORMAT0

(Sjálfgefið frá verksmiðju)

SETCANID1024

(Sjálfgefið frá verksmiðju)

SETCANBAUD1000000
MaxxECU SETCANFORMAT0

(Sjálfgefið frá verksmiðju)

SETCANID1024

(Sjálfgefið frá verksmiðju)

SETCANBAUD500000

(Sjálfgefið frá verksmiðju)

Read “Interfacing Spartan 3 to

MaxxECU.pdf”

Útvíkkað CAN-snið SETCANFORMAT5 Read “Spartan 3 Extend CAN Format.pdf”

Krefst fastbúnaðar 1.08 og nýrri.

CAN Termination Resistor:
Segjum sem svo að við köllum ECU; Master, og tæki sem senda/taka við gögnum til/frá ECU sem við köllum; Þræll (Spartan 3, stafrænt mælaborð, EGT stjórnandi, osfrv…). Í flestum forritum er einn Master (ECU) og einn eða fleiri þrælar sem allir deila sama CAN Bus. Ef Spartan 3 er eini þrællinn á CAN Bus þá ætti CAN Termmination Resistor á Spartan 3 að vera virkjaður með því að nota raðskipunina „SETCANR1“. Sjálfgefið er að CAN Termmination Resistor á Spartan 3 er virkt. Ef það eru margir þrælar, ætti þrællinn sem er lengst frá meistaranum (miðað við vírlengd) að vera með CAN stöðvunarviðnámið virkt, allir aðrir þrælar ættu að hafa sína CAN stöðvunarviðnám
óvirkur/aftengdur. Í reynd; það skiptir oft ekki máli hvort CAN stöðvunarviðnámið sé rétt stillt, en fyrir hámarks áreiðanleika ættu CAN stöðvunarviðnámið að vera rétt stillt.

Bootloader
Þegar Spartan 3 er ræst án þess að LSU hitarajarðtengingin, hvíti vírinn, sé tengdur fer það í ræsistillingu. Að ræsa Spartan 3 með hitarajarðtengingu tengda mun ekki virkja ræsistillinguna og Spartan 3 mun virka eins og venjulega.

Ábyrgð

14Point7 ábyrgist að Spartan 3 sé laus við galla í 2 ár.

Fyrirvari
14Point7 ber aðeins skaðabótaábyrgð upp að kaupverði vara sinna. 14Point7 vörur ættu ekki að nota á þjóðvegum.

Algengar spurningar

Hvað er innifalið í Spartan 3 v2 pakkanum?

The package includes the Spartan 3 v2 unit, a USB converter, a waterproof blade fuse holder, and two 5 Amp blaðöryggi.

Hvernig set ég upp USB samskipti við Spartan 3?

Simply connect the USB converter to your computer. Most operating systems already have the necessary drivers preinstalled for the FTDI chipset used in the converter.

Get ég knúið Spartan 3 með USB?

No, the Spartan 3 must be powered separately using a switched 12V source.

Skjöl / auðlindir

14POINT7 Spartan 3 v2 Lambda stjórnandi [pdfNotendahandbók
Spartan 3 v2 Lambda stjórnandi, Spartan 3 v2, Lambda stjórnandi, Stýrandi

Heimildir