14POINT7 Spartan 3 v2 Lambda stjórnandi

Tæknilýsing
- Vara: Spartan 3 v2
- Innihald pakka: 1x Spartan 3 v2, 1x USB breytir, 1x Vatnsheldur öryggisblaðhaldari, 2x 5 Amp blaðöryggi
Notkunarleiðbeiningar fyrir vöru
Útblástur uppsetningu
Settu inn 5 amp fuse into the fuse holder, cut the wire at the midpoint, and securely close the lid. Connect one end of the fuse holder to the Spartan 3 red wire and the other end to a switched 12V source, preferably the fuel pump relay.
Raflögn
| Vírlitur | Nafn |
|---|---|
| Rauður | Kraftur |
| Svartur | Raftækjavöllur |
USB fjarskipti
The Spartan 3 comes with a USB converter for communication with a computer. The USB converter uses the FTDI chipset, which is typically preinstalled on most operating systems.
Uppsetning á raðtengi í Windows 10
To communicate with the Spartan 3 via serial commands on Windows 10:
- Ensure Electronics Ground (Black), Heater Ground (White), and Power (Red) are connected and the Spartan 3 is powered.
- Sæktu og settu upp Termite hugbúnaðinn frá https://www.compuphase.com/software_termite.htm.
- In the Windows search bar, type “Device Manager” and open it.
- Locate the Spartan 3 USB converter listed as “USB Serial Port” (e.g., COM3).
- In Termite, click on Settings, verify the Port is correct (e.g., COM3) and set the Baud rate to 9600.
Raðskipanir
Til að slá inn raðskipanir:
- Connect Electronics Ground (Black), Heater Ground (White), and Power (Red).
- Use commands like GETHW, GETFW, SETTYPE, etc., followed by specific values as per the usage note below.
Notkunarathugið
Vísað til meðfylgjandi frvamples to understand how to format and use the serial commands effectively based on the desired settings.
Viðvörun
- Ekki tengja eða aftengja lambdaskynjarann á meðan Spartan 3 er með rafmagni.
- Lambdaskynjarinn verður mjög heitur við venjulega notkun, vinsamlegast farðu varlega þegar þú meðhöndlar hann.
- Ekki setja lambdaskynjarann þannig upp að einingin sé knúin áður en vélin þín er í gangi. Vélarræsing getur fært þéttingu í útblásturskerfinu þínu yfir á skynjarann, ef skynjarinn er þegar upphitaður getur það valdið hitalost og valdið því að innra keramikið inni í skynjaranum sprungur og afmyndast.
- Á meðan lambdaskynjarinn er í virkum útblástursstraumi verður honum að vera stjórnað af Spartan 3. Kolefni frá virkum útblásturslofti getur auðveldlega safnast upp á kraftlausan skynjara og skaðað hann.
- Líftími lambdaskynjara þegar hann er notaður með blýeldsneyti er á bilinu 100-500 klst.

Innihald pakka
1x Spartan 3 v2, 1x USB breytir, 1x Vatnsheldur öryggisblaðhaldari, 2x 5 Amp blaðöryggi
Útblástur uppsetningu
Lambdaskynjarinn ætti að vera settur upp á milli klukkan 10 og klukkan 2, minna en 60 gráður frá lóðréttu, þetta mun leyfa þyngdaraflinu að fjarlægja vatnsþéttingu úr skynjaranum.
Fyrir allar uppsetningar fyrir súrefnisskynjara verður að setja skynjarann fyrir hvarfakútinn.
Fyrir hreyfla með venjulega innsog ætti skynjarinn að vera settur upp um það bil 2 fet frá útblástursporti hreyfilsins. Fyrir hreyfla með forþjöppu skal setja skynjarann á eftir forþjöppunni. Fyrir mótor með forþjöppu ætti skynjarinn að vera settur upp 3 fet frá útblástursporti hreyfilsins.
Öryggi
Settu inn 5 amp Setjið öryggið í öryggihaldarann, klippið vírinn í miðjunni og lokið á. Annar endi öryggihaldarans tengist rauða Spartan 3 vírnum, hinn endinn tengist rofa 12[v] spennugjafa, venjulega er mælt með eldsneytisdælu-rofa.

Raflögn
| Vírlitur | Nafn | Tengist | Athugið |
| Rauður | Kraftur | Skipt 12[v] | Use fuse holder, 12[v] should be live only when engine is running. Fuel pump relay is the recommended source. |
| Svartur | Raftækjavöllur | Jarðvegur | Jörð þar sem tengibúnaður er jarðtengdur |
| Hvítur | Hitari jörð | Jarðvegur | Jarðað við undirvagn eða vélarblokk |
| Grænn | High Performance Analog
Framleiðsla |
Tengitæki;
ECU/Mælir/datalogger/etc… |
Default output is linear output; 0[v] @ 0.68 [Lambda] Linear to 5[v] @ 1.36 [Lambda], equivalent to 10-20 [AFR] for gasoline fuel |
| Brúnn | Standard Performance Analog Output | Default output is heater status; 0[v] = waiting for trigger before heating sensor, 1[v] = sensor heatup started, 2[v] = sensor heatup complete and sensor heater is in closed loop control | |
| Blár | GETUR hátt | ||
| Fjólublátt | GETUR Lágt | ||
| Appelsínugult | UART TX | “Rx-Orange” on USB converter | |
| Gulur | UART RX | “Tx-Yellow” on USB converter | |
| Grátt | UART Ground | “Gnd-Grey” on USB converter |
USB fjarskipti
Spartan 3 er með USB-breyti til að tryggja USB-samskipti við tölvuna þína. Breytirinn er byggður á vinsæla FTDI-flísinni þannig að flest stýrikerfi eru þegar með rekla uppsettan.
Windows 10 raðtengi
Electronics Ground (Black), Heater Ground (white), and Power (Red) must be connected and Spartan 3 powered to enter serial commands.
Spartan 3 cannot be powered through USB.
The recommended serial terminal is Termite, https://www.compuphase.com/software_termite.htm, vinsamlegast hlaðið niður og settu upp heildaruppsetninguna.
![]() |
![]() |
![]() |
![]() |
| Í Windows 10 leitarstikunni skaltu slá inn „Device Manager“ og opna hana. | Spartan 3 USB converter will show up as “USB Serial Port”, in this examp„COM3“ er úthlutað Spartan 3. | Í Termite, smelltu á „Stillingar“ | Make sure the Port is correct and that the
Baud rate is “9600”. |
Raðskipanir
Jarðtenging rafeindabúnaðar (svartur), jarðtenging hitara (hvítur) og aflgjafi (rauður) verða að vera tengd og Spartan 3 knúinn til að slá inn raðskipanir. Ekki er hægt að knýja Spartan 3 í gegnum USB.
| Raðskipun | Notkunarathugið | Tilgangur | Example | Sjálfgefið verksmiðju |
| GETHW | Fær vélbúnaðarútgáfu | |||
| GETFW | Fær vélbúnaðarútgáfu | |||
| SETTYPex | Ef x er 0 þá er Bosch LSU 4.9
Ef x er 1 þá er Bosch LSU ADV |
Stillir gerð LSU skynjara | SETTYPE1 | x=0, LSU 4.9 |
| GETTYPE | Fær LSU skynjara gerð | |||
| SETCANFORMATx | x er heil tala 1 til 3 stafa löng. x=0; sjálfgefið
x=1; Link ECU x=2; Adaptronic ECU x=3; Haltech ECU x=4; % Oxygen*100 x=5; Extended CAN format |
SETCANFORMAT0 | x=0 | |
| GETCANFORMAT | Fær CAN snið | |||
| SETCANIDx | x er heil tala 1 til 4 stafir að lengd | Stillir 11 bita CAN auðkenni | SETCANID1024
SETCANID128 |
x=1024 |
| GETCANID | Fær 11 bita CAN auðkenni | |||
| SETCANBAUDx | x er heil tala 1 til 7 stafir að lengd | Stillir CAN Baud Rate | SETCANBAUD1000000
mun stilla CAN Baud hlutfall í 1Mbit/s |
X=500000,
500kbit / s |
| GETCANBAUD | Fær CAN Baud Rate | |||
| SETCANRx | Ef x er 1 er viðnámið virkt. Ef x er 0 þá
viðnám er óvirkt |
Virkja/slökkva á CAN
Uppsagnarviðnám |
SETCANR1
SETCANR0 |
x=1, CAN term Res
Virkt |
| GETCANR | Fær CAN Term Res State;
1=virkt, 0=óvirkt |
| SETAFRMxx.x | xx.x er aukastaf nákvæmlega 4 stafir að lengd
þar á meðal aukastaf |
Sets AFR Multiplier for Torque
app |
SETAFM14.7
SETAFM1.00 |
xx.x=14.7 |
| GETAFRM | Gets AFR Multiplier for Torque
app |
|||
| SETLAMFIVEVx.xx | x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be
higher or lower than the SETLAMZEROV value. |
Stillir Lambda á 5[v] fyrir línulega úttakið | SETLAMFIVEV1.36 | x.xx=1.36 |
| GETLAMFIVEV | Fær Lambda á 5[v] | |||
| SETLAMZEROVx.xx | x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be
higher or lower than the SETLAMFIVEV value. |
Stillir Lambda á 0[v] fyrir línulega úttakið | SETLAMZEROV0.68 | x.xx=0.68 |
| GETLAMZEROV | Fær Lambda á 0[v] | |||
| SETPERFx | If x is 0 then standard performance of 20ms. If x is 1 then high performance of 10ms. If x is 2
then optimize for lean operation. |
SETPERF1 | x=1, high performance | |
| GETPERFx | Fær frammistöðu | |||
| SETSLOWHEATx | Ef x er 0 þá er skynjari hituð á eðlilegum hraða við upphaflega ræsingu.
Ef x er 1 þá er skynjari hituð við 1/3 af eðlilegum hraða við upphaflega virkjun. If x is 2 then wait, a max of 10 min, for MS3 CAN RPM signal before heating. If x is 3 then wait, a max of 10 min, for exhaust gas to heat sensor to 350C before heating. Krefst fastbúnaðar 1.05 og nýrri |
SETJA HEIT1 | x=0, normal sensor heatup rate | |
| HÆGT HEITI | Fær hægan hita stillingu | |||
| MEMRESET | Endurstilla í verksmiðjustillingar. | |||
| SETLINOUTx.xxx | Where x.xxx is a decimal exactly 5 characters long including decimal point, greater than 0.000 and less than 5.000. Linear Output will resume
normal operation on reboot. |
Leyfir notandanum að stilla High Perf Linear Output á tiltekið magntage | SETLINOUT2.500 | |
| DOCAL | Pull sensor out of the exhaust. Power on wideband controller with sensor connected for about 5 minutes then issue the DOCAL command. | Do Free Air Calibration and display the value. A perfect sensor will have a value of 1.00. Recommended for clone
nema skynjara. |
||
| GETCAL | Krefst fastbúnaðar 1.04 og nýrri | Fær ókeypis loftkvörðunargildi | ||
| RESETCAL | Krefst fastbúnaðar 1.04 og nýrri | Endurstillir ókeypis loftkvörðun
verðmæti 1.00 |
||
| SETCANDRx | x er heiltala sem er 1 til 4 stafir að lengd. Krefst vélbúnaðar 1.04 og nýrri. | Stillir CAN Data Rate í hz | For optimal performance, CAN Data
Rate should be 200hz |
x=50 |
| GETCANDR | Krefst fastbúnaðar 1.04 og nýrri | Fær CAN Data Rate | ||
| SETNBMODEx | If x is 0 then Standard Performance Analog Output is Simulated Narrowband.
Ef x er 2 þá er staðlað afköst hliðrænt Úttak er staða hitara |
Selects the function of the Standard Performance Analog Output between Simulated
Staða þröngbands og hitara |
SETNBMODE0 | x=2, Heater Status |
| GETNBMODE | Fær staðlaða afköst
Analog útgangsstilling |
|||
| SETNBSWLAMx.xxx | x.xxx is a decimal exactly 5 characters long including decimal point. Requires Firmware
1.08 og ofar |
Sets the Simulated Narrowband Switch Point in Lambda | SETNBSWLAM1.005 | x.xxx=1.000 |
| GETNBSWLAM | Fær herma Narrowband
skiptipunktur í Lambda |
*Allar skipanir eru í ASCII, lág- og lágstafir skipta ekki máli, bil skipta ekki máli.
CAN Bus Protocol Sjálfgefið snið (Lambda)
Fyrir %O2 CAN snið vinsamlegast sjá “Spartan 3 og Spartan 3 Lite fyrir maga brennslu og súrefnismælingarforrit.pdf” CAN Bus Spartan 3 starfar með 11 bita vistföng.
- Sjálfgefinn CAN Baud hraði er 500kbit/s
- Sjálfgefin CAN stöðvunarviðnám er virkt, þessu er hægt að breyta með því að senda „SETCANRx“ raðskipun.
- Sjálfgefið CAN auðkenni er 1024, þessu er hægt að breyta með því að senda „SETCANIDx“ raðskipun.
- Gagnalengd (DLC) er 4.
- Default Data Rate is 50 hz, data is sent every 20[ms], this can be changed by sending “SETCANDRx” serial command. Big-endian for all data
- Gögn[0] = Lambda x1000 High Byte
- Gögn[1] = Lambda x1000 Low Byte
- Gögn[2] = LSU_Temp/10
Gögn[3] = Staða - Lambda = (Gögn[0]<<8 + Gögn[1])/1000
- Hitastig skynjara [C] = Gögn[2]*10
Staða
| Status Value (decimal) | Merking |
| 0 | Frátekið |
| 1 | Waiting for trigger before heating up |
| 2 | Sensor is heating up |
| 3 | Sensor in normal operation |
| 4+ | Frátekið |
Supported CAN Formats
| CAN Format Name | CAN Format Serial
Skipun |
CAN Id Serial
Skipun |
CAN BAUD Rate Serial
Skipun |
Athugið |
| Link ECU CAN Format | SETCANFORMAT1 | SETCANID950 | SETCANBAUD1000000 | Read “Link G4+ ECU CAN Bus Configuration
for Spartan 3.pdf” |
| Adaptronic ECU CAN
Snið |
SETCANFORMAT2 | SETCANID1024
(Sjálfgefið frá verksmiðju) |
SETCANBAUD1000000 | |
| MegaSquirt 3 ECU
CAN snið |
SETCANFORMAT0
(Sjálfgefið frá verksmiðju) |
SETCANID1024
(Sjálfgefið frá verksmiðju) |
SETCANBAUD500000
(Sjálfgefið frá verksmiðju) |
Read “Interfacing Spartan 3 to MegaSquirt
3.pdf“ |
| Haltech ECU CAN
Snið |
SETCANFORMAT3 | Ekki krafist | SETCANBAUD1000000 | Spartan 3 líkir eftir Haltech WBC1
breiðbandsstýring |
| YourDyno Dyno
Controller CAN Format |
SETCANFORMAT0
(Sjálfgefið frá verksmiðju) |
SETCANID1024
(Sjálfgefið frá verksmiðju) |
SETCANBAUD1000000 | |
| MaxxECU | SETCANFORMAT0
(Sjálfgefið frá verksmiðju) |
SETCANID1024
(Sjálfgefið frá verksmiðju) |
SETCANBAUD500000
(Sjálfgefið frá verksmiðju) |
Read “Interfacing Spartan 3 to
MaxxECU.pdf” |
| Útvíkkað CAN-snið | SETCANFORMAT5 | Read “Spartan 3 Extend CAN Format.pdf”
Krefst fastbúnaðar 1.08 og nýrri. |
CAN Termination Resistor:
Segjum sem svo að við köllum ECU; Master, og tæki sem senda/taka við gögnum til/frá ECU sem við köllum; Þræll (Spartan 3, stafrænt mælaborð, EGT stjórnandi, osfrv…). Í flestum forritum er einn Master (ECU) og einn eða fleiri þrælar sem allir deila sama CAN Bus. Ef Spartan 3 er eini þrællinn á CAN Bus þá ætti CAN Termmination Resistor á Spartan 3 að vera virkjaður með því að nota raðskipunina „SETCANR1“. Sjálfgefið er að CAN Termmination Resistor á Spartan 3 er virkt. Ef það eru margir þrælar, ætti þrællinn sem er lengst frá meistaranum (miðað við vírlengd) að vera með CAN stöðvunarviðnámið virkt, allir aðrir þrælar ættu að hafa sína CAN stöðvunarviðnám
óvirkur/aftengdur. Í reynd; það skiptir oft ekki máli hvort CAN stöðvunarviðnámið sé rétt stillt, en fyrir hámarks áreiðanleika ættu CAN stöðvunarviðnámið að vera rétt stillt.
Bootloader
Þegar Spartan 3 er ræst án þess að LSU hitarajarðtengingin, hvíti vírinn, sé tengdur fer það í ræsistillingu. Að ræsa Spartan 3 með hitarajarðtengingu tengda mun ekki virkja ræsistillinguna og Spartan 3 mun virka eins og venjulega.
Ábyrgð
14Point7 ábyrgist að Spartan 3 sé laus við galla í 2 ár.
Fyrirvari
14Point7 ber aðeins skaðabótaábyrgð upp að kaupverði vara sinna. 14Point7 vörur ættu ekki að nota á þjóðvegum.
Algengar spurningar
Hvað er innifalið í Spartan 3 v2 pakkanum?
The package includes the Spartan 3 v2 unit, a USB converter, a waterproof blade fuse holder, and two 5 Amp blaðöryggi.
Hvernig set ég upp USB samskipti við Spartan 3?
Simply connect the USB converter to your computer. Most operating systems already have the necessary drivers preinstalled for the FTDI chipset used in the converter.
Get ég knúið Spartan 3 með USB?
No, the Spartan 3 must be powered separately using a switched 12V source.
Skjöl / auðlindir
![]() |
14POINT7 Spartan 3 v2 Lambda stjórnandi [pdfNotendahandbók Spartan 3 v2 Lambda stjórnandi, Spartan 3 v2, Lambda stjórnandi, Stýrandi |