The Forney 58402 is a heavy-duty Bakelite pin-type wall electrical receptacle designed for surface mounting. It features a 2-pole/3-wire grounding configuration, suitable for high-power applications. This receptacle is rated for 50 Amps at 125/250 Volts and conforms to NEMA 6-50 standards.
Helstu eiginleikar:
- Heavy duty Bakelite pin-type design for durability.
- Wall electrical receptacle for surface mounting.
- 2-pole/3-wire grounding for enhanced safety.
- 50 Amp with 125/250-Volt capacity.
- NEMA 6-50 electrical configuration.

Mynd 1: Framan view of the Forney 58402 Electrical Receptacle, showing the pin configuration and voltage/ampeyða einkunnum.
2. Öryggisupplýsingar
VIÐVÖRUN: Electrical work can be hazardous. Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing this receptacle. Failure to do so may result in serious injury or death. If you are unsure about any part of these instructions, consult a qualified electrician.
- Gakktu úr skugga um að öllum staðbundnum og landsbundnum rafmagnsreglum sé fylgt.
- Notið viðeigandi persónuhlífar (PPE), svo sem einangrandi hanska og öryggisgleraugu.
- Staðfestu binditage og amperage of your circuit match the receptacle's ratings (50A, 125/250V).
- Do not use this receptacle if it appears damaged.
- Haldið börnum fjarri raforkuvirkjum.
3. Uppsetning og uppsetning
This section provides general guidelines for installing the Forney 58402 wall receptacle. Specific wiring configurations may vary based on local codes and existing electrical systems.
Verkfæri og efni krafist:
- Skrúfjárn (Phillips og Flathead)
- Vír Strippers
- Voltage prófanir
- Mounting screws (appropriate for surface)
- Rafmagnskassi (ef hann er ekki þegar til staðar)
Uppsetningarskref:
- Aftengdu rafmagn: Locate the circuit breaker or fuse controlling the circuit where the receptacle will be installed and turn it OFF. Verify power is off using a voltage prófari.
- Undirbúðu uppsetningaryfirborð: Ensure the surface is clean, dry, and structurally sound. The receptacle is designed for surface mounting.
- Mount the Receptacle Base: Position the receptacle base on the desired surface. Use appropriate mounting screws to secure it firmly. The back of the receptacle features pre-drilled holes for this purpose.
- Vírtengingar: This receptacle is a 2-pole/3-wire grounding type (NEMA 6-50). It typically requires two hot wires (L1, L2) and one ground wire.
- Fjarlægðu um það bil 1/2 tommu af einangruninni af hverjum vír.
- Connect the L1 (Hot) wire to one of the brass-colored terminals.
- Connect the L2 (Hot) wire to the other brass-colored terminal.
- Connect the Ground wire (typically green or bare copper) to the green hexagonal grounding screw.
- Örugg raflögn: Ensure all wire connections are tight and secure. No bare wire should be exposed outside the terminals.
- Settu saman aftur: Carefully place the cover over the wired base and secure it with the provided screws.
- Endurheimta kraft: Once installation is complete and verified, turn the power back ON at the circuit breaker or fuse box.

Mynd 2: Til baka view of the Forney 58402 Receptacle, showing the metal mounting plate and screw holes for surface installation.

Mynd 3: Neðst view of the Forney 58402 Receptacle, illustrating the internal wiring access points and terminals.
4. Notkunarleiðbeiningar
The Forney 58402 Electrical Receptacle is designed for straightforward operation.
- Staðfestu eindrægni: Ensure the plug of your electrical device is compatible with the NEMA 6-50 configuration of this receptacle.
- Settu inn stinga: Align the pins of your device's plug with the slots on the receptacle and firmly insert the plug.
- Remove Plug: To disconnect, grasp the plug firmly and pull it straight out from the receptacle. Do not pull by the cord.

Mynd 4: Nærmynd view of the Forney 58402 Receptacle's pin configuration, showing the 50A 250V markings.
5. Viðhald
Regular inspection and basic maintenance will help ensure the longevity and safe operation of your Forney 58402 receptacle.
- Reglubundin skoðun: Annually inspect the receptacle for any signs of damage, cracks, discoloration, or loose connections.
- Þrif: With power disconnected, gently wipe the exterior of the receptacle with a dry, clean cloth to remove dust or debris. Do not use liquid cleaners.
- Herðið tengingar: If comfortable and with power disconnected, periodically check and tighten the terminal screws to ensure secure wire connections.
- Umhverfisvernd: Ef sett upp í auglýsinguamp or dusty environment, ensure the receptacle is adequately protected from moisture and excessive dust accumulation.
6. Bilanagreining
If you experience issues with your Forney 58402 receptacle, consider the following common troubleshooting steps:
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| Enginn straumur frá innstungunni | Aflrofi leystist út eða öryggi sprungið | Check your electrical panel and reset the breaker or replace the fuse. |
| Enginn straumur frá innstungunni | Laust raflögn | With power disconnected, inspect and tighten all wire connections within the receptacle. |
| Klípan passar ekki | Ósamhæfð tengitegund | Ensure your device's plug is a NEMA 6-50 type. Do not force incompatible plugs. |
| Receptacle feels hot | Ofhleðsla eða laus tenging | Immediately disconnect power. Reduce load or check wiring. Consult an electrician if problem persists. |
If troubleshooting steps do not resolve the issue, or if you are unsure, contact a qualified electrician.
7. Tæknilýsing
| Eiginleiki | Gildi |
|---|---|
| Vörumerki | Forney |
| Fyrirmynd | 58402 |
| Tegund | Pin-Type Wall Receptacle |
| AmpAldur | 50 Amps |
| Voltage | 125/250 Volt |
| NEMA stillingar | 6-50 |
| Staurar/vírar | 2-Pole, 3-Wire Grounding |
| Efni | Bakelite (Housing), Plastic (Body) |
| Litur | Svartur |
| Samtals rafmagnsinnstungur | 1 |
| Samhæf tæki | All (NEMA 6-50 compatible) |
8. Ábyrgð og stuðningur
Specific warranty details for the Forney 58402 Electrical Receptacle are not provided in this manual. For warranty information, technical support, or service inquiries, please refer to the product packaging or contact Forney customer service directly.