1. Inngangur
This manual provides important instructions for the safe installation, operation, and maintenance of the SIEMENS BQ3B040 40-Amp Three Pole 240-Volt Circuit Breaker. The Siemens Type BQ Circuit Breaker is a cable-in, cable-out, non-interchangeable trip molded case circuit breaker designed for reliable electrical protection. It is rated for 40 Amps, 240 Volts, and has a 10KAIC interrupting rating.
Vinsamlegast lesið þessa handbók vandlega áður en hafist er handa við uppsetningu eða notkun. Geymið handbókina til síðari viðmiðunar.

A skýr view of the SIEMENS BQ3B040 circuit breaker, showing its compact design and terminal lugs.
2. Öryggisupplýsingar
VIÐVÖRUN: Electrical shock hazard. Can cause serious injury or death. Installation and servicing of this circuit breaker must be performed by qualified, licensed electrical personnel only. Always disconnect power at the main service panel before working on or near electrical equipment.
- Always follow all local and national electrical codes.
- Ensure the power supply is completely de-energized and locked out before beginning any work.
- Notið viðeigandi persónuhlífar (PPE), þar á meðal einangrandi hanska og öryggisgleraugu.
- Never attempt to modify the circuit breaker.
- Do not install a circuit breaker that appears damaged.
3. Innihald pakka
Pakkinn inniheldur venjulega:
- One (1) SIEMENS BQ3B040 40-Amp Three Pole 240-Volt Circuit Breaker
4. Uppsetning og uppsetning
MIKILVÆGT: Uppsetning verður að vera framkvæmd af löggiltum rafvirkja í samræmi við allar gildandi rafmagnsreglur og staðla.
- Rafmagnstenging: Ensure all power to the electrical panel is turned OFF at the main disconnect and verified with a voltage tester. Lock out and tag out the main disconnect.
- Aðgangur að spjaldi: Fjarlægðu hlífina af rafmagnstöflunni varlega.
- Staðsetning rofa: Identify the appropriate slot in the panel for a three-pole breaker.
- Tenging: Connect the load wires to the designated terminals on the circuit breaker. The BQ3B040 is a lug-out breaker, meaning wires connect directly to the lugs. Ensure all connections are tight and secure, adhering to torque specifications if provided on the breaker or panel.
- Uppsetning: Snap the circuit breaker firmly into place on the bus bar. Ensure it is fully seated.
- Samsetning spjaldsins: Skiptu um hlífina á rafmagnstöflunni.
- Rafmagnsendurheimt: Endurræstu rafmagnið á aðalþjónustuborðinu.
5. Notkunarleiðbeiningar
The SIEMENS BQ3B040 circuit breaker operates as a protective device for your electrical circuit. It has three primary states:
- Kveikt: In this position, power is flowing through the circuit breaker to the connected load.
- SLÖKKT: In this position, power to the connected load is interrupted.
- TRIPPED: If an overload or short circuit occurs, the breaker will automatically move to a tripped position (often midway between ON and OFF, or fully OFF depending on the design). This indicates a fault in the circuit.
To reset a tripped breaker, first move the handle firmly to the OFF position, then push it to the ON position. If the breaker immediately trips again, do not attempt to reset it repeatedly. Investigate the cause of the fault.
6. Viðhald
Rofar þurfa almennt lágmarks viðhald. Hins vegar er mælt með reglulegu eftirliti:
- Sjónræn skoðun: Annually, or as local codes require, have a qualified electrician inspect the circuit breaker and its connections for any signs of overheating, loose wires, or physical damage.
- Þrif: Ensure the area around the circuit breaker is free from dust and debris. Do not use liquids for cleaning inside the electrical panel.
- Próf: Do not attempt to test the tripping mechanism yourself. This should only be done by qualified professionals using specialized equipment.
7. Bilanagreining
If you experience issues with your circuit breaker, consider the following:
- Brotferðir oft: This indicates an overload or a short circuit on the protected circuit. Disconnect some appliances or devices from the circuit, or inspect for damaged wiring. If the problem persists, consult a qualified electrician.
- Rofinn endurstillist ekki: If the breaker immediately trips after being reset, a persistent fault (overload or short circuit) is present. Do not force the breaker.
- Enginn straumur í rafrásina: Check if the breaker is in the OFF or TRIPPED position. If it is ON and there is still no power, check other breakers or consult an electrician.
Ef um langvarandi eða flókin rafmagnsvandamál er að ræða skal alltaf hafa samband við löggiltan rafvirkja.
8. Tæknilýsing
| Eiginleiki | Forskrift |
|---|---|
| Vörumerki | SIEMENS |
| Gerðarnúmer | BQ3B040 |
| Núverandi einkunn | 40 Amps |
| Voltage | 240 volt |
| Fjöldi Pólverja | 3 |
| Aflrofi gerð | Staðlað, hitasegulmagnað |
| Gerð uppsetningar | Stöngfjall |
| Trufla einkunn | 10KAIC |
| Vörumál | 30" D x 8" B x 6" H |
| Þyngd hlutar | 10.7 aura |
| Efni | Gler |
| Innifalið íhlutir | BQ3B040 |
9. Ábyrgð og stuðningur
Siemens mælir eindregið gegn notkun á „notuðum“ rofum. Uppsetning notaðra rofa í Siemens rafrás ógildir ábyrgðina á rafrásinni. Siemens selur ekki notaða rofa og hefur ekki samþykkt neina þriðja aðila til þess.
For technical support, warranty claims, or further assistance, please contact Siemens customer service or visit the official Siemens website. Always refer to your purchase documentation for specific warranty terms and conditions.
Tilföng á netinu: Heimsæktu SIEMENS verslunina á Amazon