The Fieldpiece SC620 is a professional-grade loaded clamp multimeter designed for HVACR technicians. It provides comprehensive electrical measurements including AC/DC voltage, AC current, DC microamps, frequency, temperature, and capacitance. This manual provides essential information for safe and effective operation of your SC620 multimeter. Please read this manual thoroughly before using the device.

Innihald pakka
The Fieldpiece SC620 package typically includes:
- SC620 Clamp Margmælir
- Test Leads with Alligator Clips
- 9V rafhlaða (innifalin)
- Notendahandbók (þetta skjal)
Eiginleikar vöru
The Fieldpiece SC620 offers a range of features for HVACR diagnostics:
- Ráðstafanir Volts AC/DC
- Ráðstafanir 400 Amps AC
- Ráðstafanir Öramps DC for flame diode tests
- Ráðstafanir Tíðni via leads and clamp
- Snertilaus binditage (NCV) vísir
- Snúningshaus for easy access in tight spaces
- Hábinditage LED and beeper til öryggis
- Continuity warning
- Lead holder with detachable leads and alligator probe tips
- Hitastig og Rýmd mælingar
Uppsetning
1. Uppsetning rafhlöðu
The SC620 multimeter requires one 9V battery for operation. The battery is typically included with the device. To install or replace the battery:
- Finndu rafhlöðulokið aftan á fjölmælinum.
- Notaðu skrúfjárn til að opna hólfið.
- Insert a new 9V battery, observing the correct polarity (+/-).
- Lokaðu hlífinni á rafhlöðuhólfinu örugglega.
2. Að tengja prófunarsnúrur
Connect the red test lead to the VΩmA input jack and the black test lead to the COM input jack. Ensure the connections are firm. For current measurements using the clamp, no lead connection is required for the primary measurement, but leads may be used for other functions simultaneously.
Notkunarleiðbeiningar
1. Kveikt/slökkt
Rotate the function dial to any measurement setting to power on the multimeter. To power off, rotate the dial to the 'OFF' position.
2. AC/DC Voltage Mæling
Til að mæla voltage:
- Rotate the function dial to the 'V~' (AC Voltage) eða 'V=' (jafnvægisrúmmáltage) stöðu.
- Connect the test leads to the circuit in parallel.
- Lestu binditage gildi á skjánum.
3. AC Current Measurement (Clamp)
Til að mæla AC straum:
- Rotate the function dial to the 'A~' (AC Amps) stöðu.
- Opnaðu clamp jaw and enclose a single conductor of the circuit.
- Gakktu úr skugga um að kjálkinn sé alveg lokaður.
- Lesið núverandi gildi á skjánum.
4. DC Microamps Mæling
To measure DC microamps (e.g., for flame diode tests):
- Rotate the function dial to the 'µA=' (DC Microamps) stöðu.
- Connect the test leads in series with the component to be measured.
- Read the microampere value on the display.
5. Resistance and Continuity
To measure resistance or check continuity:
- Rotate the function dial to the 'Ω' (Resistance) position.
- Tengdu prófunarleiðslurnar yfir íhlutinn.
- For continuity, the meter will beep if a low resistance path is detected.
6. Tíðnimæling
The SC620 can measure frequency via leads or clamp. Rotate the function dial to the 'Hz' position and follow the appropriate connection method.
7. Non-Contact Voltage (NCV)
Press the NCV button to activate the non-contact voltage detection feature. Hold the tip of the meter near a live AC voltage source. The meter will indicate the presence of voltage with an LED and an audible beep.
8. Hitamæling
Connect a Type K thermocouple (if included, typically sold separately or as part of a kit) to the designated temperature input jacks. Rotate the function dial to the 'TEMP' position to measure temperature.
9. Rafmagnsmæling
Til að mæla rýmd:
- Rotate the function dial to the 'nF' (Capacitance) position.
- Ensure the capacitor is discharged before connecting the test leads.
- Tengdu prófunarleiðslurnar yfir þéttinn.
- Lestu rýmigildið á skjánum.
Viðhald
1. Þrif
Wipe the multimeter with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or use.
2. Skipt um rafhlöðu
Replace the 9V battery when the low battery indicator appears on the display. Refer to the 'Battery Installation' section for instructions.
3. Geymsla
Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.
Úrræðaleit
1. No Display or Faint Display
- Check battery charge. Replace the 9V battery if low.
- Ensure the function dial is not in the 'OFF' position.
2. Incorrect Readings
- Verify test lead connections are secure and correct for the measurement type.
- Ensure the correct function and range are selected.
- Check for damaged test leads.
- For current measurements, ensure only one conductor is clampútg.
3. No Continuity Beep
- Ensure the meter is in the continuity mode.
- Check for an open circuit or high resistance in the component being tested.
Tæknilýsing

| Forskrift | Gildi |
|---|---|
| Gerðarnúmer | SC620 |
| Mál | 3.8 x 3.2 x 14.6 tommur |
| Þyngd | 1.7 pund |
| Aflgjafi | 1 x 9V rafhlaða (innifalin) |
| Tegund mælingar | Stafræn |
| Litur | Black, Gray, Yellow |
| Framleiðandi | Vettvangur |
| ASIN | B00KLYJS76 |
Ábyrgð og stuðningur
Upplýsingar um ábyrgð
For detailed warranty information, please refer to the documentation provided with your purchase or visit the official Fieldpiece webGeymið kaupkvittunina vegna ábyrgðarkröfu.
Þjónustudeild
If you encounter any issues or have questions regarding your Fieldpiece SC620 multimeter, please contact Fieldpiece customer support through their official websíðuna eða upplýsingar um tengilið sem fylgja með í umbúðum vörunnar.