1. Inngangur
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your CATA X-Mart 12 Matic Inox Exhaust Fan. Please read these instructions carefully before using the appliance and retain them for future reference.
The CATA X-Mart 12 Matic Inox is a recessed perimetral bathroom exhaust fan designed for effective ventilation. It features a unique automatic shutter system, a removable screw-less front for easy cleaning, and a streamlined design for improved airflow.
2. Öryggisupplýsingar
VIÐVÖRUN: Ef þessum öryggisleiðbeiningum er ekki fylgt getur það valdið raflosti, eldsvoða eða líkamstjóni.
- Gangið úr skugga um að rafmagnið sé aftengt áður en uppsetning, viðhald eða þrif fara fram.
- Uppsetning verður að vera framkvæmd af löggiltum rafvirkja í samræmi við allar gildandi rafmagnsreglur á hverjum stað og á landsvísu.
- Do not install the fan in areas where flammable or explosive gases may be present.
- Þetta tæki er ekki ætlað til notkunar af einstaklingum (þar á meðal börnum) með skerta líkamlega, skynræna eða andlega getu, eða skort á reynslu og þekkingu, nema þeir hafi fengið eftirlit eða leiðbeiningar um notkun tækisins af einstaklingi sem ber ábyrgð á öryggi þeirra. .
- Haltu börnum frá heimilistækinu.
- Do not operate the fan if any part is damaged. Contact qualified service personnel for repairs.
- Gakktu úr skugga um rétta jarðtengingu tækisins.
- The fan is designed for indoor use only, specifically for bathrooms.
3. Innihald pakka
Gakktu úr skugga um að allir íhlutir séu til staðar og óskemmdir áður en haldið er áfram með uppsetningu.
- 1 x CATA X-Mart 12 Matic Inox Exhaust Fan Body
- 1 x Leiðbeiningarhandbók (þetta skjal)
Note: Additional mounting hardware (screws, wall plugs, ducting) may be required and are typically not included.
4. Vörulýsing
| Eiginleiki | Forskrift |
|---|---|
| Vörumerki | CATA |
| Gerðarnúmer | 01055000 |
| Rafmagns viftu hönnun | Útblástursvifta |
| Litur | INOX |
| Aflgjafi | Rafmagns |
| Herbergistegund | Baðherbergi |
| Sérstakur eiginleiki | Automatic Shutter System |
| Hávaðastig | 40 desibel |
| Hvaðtage | 20 Watt |
| Gerð klára | Ryðfrítt stál |
| Þyngd hlutar | 0.88 kíló |
| Stærðir hlutar (LxBxH) | 17 x 13.9 x 17 sentimetrar |
| Soggeta | 190 m³/klst |
| Þvermál | 120 mm |
Figure 4.1: Performance curve for the X-Mart Matic 12, illustrating the relationship between static pressure and airflow volume.
5. Uppsetning og uppsetning
The CATA X-Mart 12 Matic Inox fan is designed for fully recessed installation in walls or ceilings. It features an easy screw-less installation system.
5.1 Athuganir fyrir uppsetningu
- Ensure the installation location is suitable for an exhaust fan, considering ventilation requirements and proximity to moisture sources.
- Verify that the wall or ceiling opening matches the fan's dimensions. Refer to the dimension diagram below.
- Confirm that the electrical supply meets the fan's requirements (20 Watts, standard household voltagog).
- Gather necessary tools: screwdriver, drill, measuring tape, wire strippers, safety gloves, safety glasses.
Figure 5.1: Dimensional drawing for X-Mart Matic series. For Model 12, refer to the row with B=170mm, C=101mm, and ØA=118mm.
5.2 Uppsetningarskref
- Aftengdu rafmagn: Slökkvið á aðalrafmagninu á uppsetningarsvæðinu við rofann.
- Undirbúa opnun: Create or verify an opening in the wall or ceiling that accommodates the fan's dimensions (approximately 118mm diameter for the duct, and 170x170mm for the main body recess).
- Mount Fan Body: Insert the fan body into the prepared opening. The screw-less installation system allows for easy securing. Ensure it is flush with the surface.
- Rafmagnstenging: Connect the electrical wiring to the fan's terminal block. Ensure correct polarity (Live, Neutral, Earth) and secure all connections. Refer to local electrical codes.
- Attach Ducting (if applicable): If connecting to an external duct, secure the ducting to the fan's outlet using appropriate clamps eða segulband.
- Setjið upp framhliðina: Attach the removable screw-less front cover to the fan body. Ensure it clicks securely into place.
- Endurheimta kraft: Þegar uppsetningu er lokið og allar tengingar eru öruggar skal endurræsa strauminn við rofann.
- Prófunaraðgerð: Turn on the fan to ensure it operates correctly. Observe the automatic front opening and airflow.
Figure 5.2: CATA X-Mart 12 Matic Inox Exhaust Fan, front view.
6. Notkunarleiðbeiningar
The CATA X-Mart 12 Matic Inox Exhaust Fan is designed for straightforward operation.
- Kveikt/slökkt: The fan is typically connected to a light switch or a dedicated fan switch in the bathroom. Flipping the switch to the 'ON' position will activate the fan.
- Automatic Shutter: Upon activation, the fan's automatic front opening mechanism will engage, allowing air to flow. When the fan is turned off, the shutter will close to prevent backdraft and maintain insulation.
- Notkunarljós: A small indicator light on the front panel will illuminate when the fan is operating, providing a visual confirmation of its status.
- Loftflæði: The fan will draw stale, humid air from the room and expel it through the ducting system, improving air quality and reducing moisture.
7. Viðhald
Regular cleaning and maintenance will ensure optimal performance and longevity of your exhaust fan.
7.1 Hreinsun viftunnar
- Aftengdu rafmagn: Always turn off the power supply to the fan at the circuit breaker before cleaning.
- Fjarlægðu framhliðina: The fan features a removable screw-less front for easy access. Gently unclip or detach the front cover.
- Hreinsa hlíf: Wash the front cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.
- Clean Fan Blades and Interior: Use a soft cloth or a vacuum cleaner with a brush attachment to carefully remove dust and debris from the fan blades, motor housing, and interior surfaces. Do not use abrasive cleaners or allow water to enter the motor.
- Reattach Front Cover: Once all parts are clean and dry, securely reattach the front cover.
- Endurheimta kraft: Kveiktu aftur á aflgjafanum.
Recommended cleaning frequency: Every 3-6 months, or more often in dusty or high-humidity environments.
8. Bilanagreining
If you encounter issues with your CATA X-Mart 12 Matic Inox Exhaust Fan, refer to the following common problems and solutions:
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| Viftan kviknar ekki. | Engin aflgjafi; lausar raflagnir; bilaður rofi. | Check circuit breaker. Ensure switch is ON. Verify wiring connections (consult an electrician if unsure). |
| Fan is noisy or vibrating. | Laus festing; óhreinindi í viftublöðum; vandamál með mótor. | Ensure fan is securely mounted. Disconnect power and clean fan blades. If noise persists, contact service. |
| Lélegt loftflæði. | Blocked ducting; dirty fan blades; automatic shutter not opening fully. | Clean fan blades and interior. Check ducting for obstructions. Ensure shutter mechanism is free of debris. |
| Automatic shutter not opening/closing. | Obstruction; mechanism fault. | Disconnect power and carefully check for any physical obstructions around the shutter mechanism. Clean if necessary. |
Ef vandamálið er enn til staðar eftir að þessar lausnir hafa verið prófaðar, vinsamlegast hafið samband við hæfan þjónustuaðila.
9. Ábyrgð og stuðningur
CATA products are manufactured to high-quality standards. For information regarding warranty coverage, terms, and conditions, please refer to the warranty card included with your purchase or visit the official CATA websíða.
For technical support, spare parts, or service inquiries, please contact your local CATA distributor or authorized service center. When contacting support, please have your model number (01055000) and purchase details readily available.