1. Inngangur
The AIMS Power 3600 Watt Modified Sine Power Inverter converts 12 Volt DC battery power to 120 Volt AC household power. This unit is ETL Listed and conforms to UL 458 Standards, as well as CSA Standard C22.2 No. 107.1-01 in Canada. It is designed for various applications including mobile power, backup systems, or off-grid power solutions in homes, RVs, cabins, boats, and vehicles.
Key features include 3600W continuous power and 7200W surge capability, dual GFCI outlets, and an AC direct connect terminal block for full wattage delivery. The inverter incorporates soft start technology and comprehensive protections against overload, over temperature, high/low voltage, and short circuits. Integrated volt and amp meters allow for performance monitoring, complemented by LED indicators for power and fault conditions.
2. Mikilvægar öryggisleiðbeiningar
VIÐVÖRUN: Ef þessum leiðbeiningum er ekki fylgt getur það valdið alvarlegum meiðslum eða eignatjóni.
- Loftræsting: Ensure the inverter is installed in a well-ventilated area to prevent overheating. Do not block ventilation openings.
- Raki: Do not expose the inverter to rain, snow, spray, or bilge water. Do not install in a wet environment.
- Eldfimt efni: Do not install the inverter in compartments containing flammable materials or where flammable fumes may accumulate.
- Rafhlöðu tengingar: Always connect the inverter to a 12V DC battery system. Ensure correct polarity (red to positive, black to negative) to avoid damage. Use appropriate gauge cables for connections.
- Jarðtenging: The inverter must be properly grounded. Connect the grounding terminal to a suitable earth ground.
- Hæft starfsfólk: Installation and servicing should be performed by qualified personnel familiar with electrical systems and safety procedures.
- Börn: Keep the inverter and all associated wiring out of reach of children.
3. Innihald pakka
Your AIMS Power 3600 Watt Modified Sine Power Inverter package includes the following items:
- AIMS Power 3600 Watt Modified Sine Power Inverter
- Leiðbeiningarhandbók
- DC Battery Terminal Covers (Red and Black)
4. Eiginleikar og íhlutir vörunnar
The AIMS Power 3600 Watt Modified Sine Power Inverter is engineered for robust performance and user convenience. Below are its primary features and components:
- Afköst: 3600W maximum continuous power, 7200W surge capability, with soft start technology.
- Innstungur fyrir rafmagn: Tvöfaldur 20 Amp GFCI (Ground Fault Circuit Interrupter) outlets for enhanced safety.
- AC tengiklemmur: Direct connect AC terminal block capable of delivering the full 3600 watts to a single source.
- DC inntak: Rugged DC terminals for secure battery connections.
- Verndareiginleikar: Overload, over temperature, high voltage, lág binditage, short circuit, internally fused, low and high voltage alarm, cooling fan, and isolated ground neutral.
- Eftirlit: Integrated Volt and Amp meters to monitor inverter performance. LED indicators for power and fault conditions.
- Tíðni rofi: A switch to select between 50Hz and 60Hz output, if needed.
- Fjarlæg höfn: Dedicated port for an optional remote switch (adapter cable included).

Mynd 4.1: Á heildina litið view of the AIMS Power 3600 Watt Modified Sine Power Inverter.

Figure 4.2: Front panel showing AC outlets, terminal block, and controls.

Figure 4.3: Rear panel displaying the DC input terminals and cooling fans.

Mynd 4.4: Ítarleg view of the dual GFCI outlets and the AC direct connect terminal block.

Mynd 4.5: Ítarleg view of the DC input terminals with protective covers.
Myndband 4.1: Yfirview of the AIMS Power 3600 Watt Modified Sine Inverter, highlighting its features and connection points.
5. Uppsetning og uppsetning
Proper installation is crucial for the safe and efficient operation of your inverter. Follow these steps carefully:
5.1 Að velja staðsetningu
- Install the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and moisture.
- Ensure adequate clearance around the inverter for proper airflow to the cooling fans.
- Festið inverterinn örugglega á stöðugt, óeldfimt yfirborð.
5.2 DC Input Connection (Battery)
- Gakktu úr skugga um að rofi invertersins sé í SLÖKKT stöðu.
- Connect the supplied DC battery terminal covers to the appropriate terminals on the inverter: red to positive (+), black to negative (-).
- Connect the other end of the DC cables to your 12V DC battery bank, ensuring correct polarity. Use heavy-gauge cables suitable for the inverter's wattage.
- Tighten all connections securely to prevent loose connections, which can cause overheating and damage.
5.3 AC Output Tenging
- GFCI útsölustaðir: For standard AC appliances, plug them directly into the dual 20A GFCI outlets on the front panel.
- AC tengiklemmur: For applications requiring the full 3600W or a hardwired connection, use the AC direct connect terminal block. Consult a qualified electrician for proper wiring to this block. Ensure all wiring adheres to local electrical codes.
5.4 Remote Switch Connection (Optional)
If using an optional remote switch, connect its cable to the dedicated remote port on the inverter's front panel. An adapter cable is included for this purpose.
6. Notkunarleiðbeiningar
Þegar inverterinn hefur verið rétt uppsettur og tengdur skaltu fylgja þessum skrefum til að stjórna honum:
6.1 Kveikt/slökkt
- Ensure all AC loads are disconnected or turned off before powering on the inverter.
- Flip the main power switch on the inverter to the "ON" position. The green LED indicator should illuminate, and the volt/amp meters will display readings.
- If using a remote switch, ensure the inverter's main switch is ON, then use the remote switch to control the inverter's power.
- To power off, first disconnect or turn off all AC loads, then flip the inverter's main power switch to "OFF."
6.2 Eftirlit með afköstum
- The integrated volt and amp meters provide real-time feedback on your system's performance. Monitor these displays to ensure stable operation and prevent overloading.
- LED indicators will show green for normal operation and red for fault conditions (e.g., overload, over temperature).
6.3 Tíðnival
A switch is provided on the unit to change the output frequency between 50Hz and 60Hz. Adjust this setting according to the requirements of your connected appliances.
7. Viðhald
Regular maintenance ensures the longevity and optimal performance of your AIMS Power Inverter:
- Þrif: Hreinsið reglulega ytra byrði invertersins með þurrum klút. Gangið úr skugga um að loftræstiop séu laus við ryk og óhreinindi. Notið ekki fljótandi hreinsiefni.
- Tengingarathuganir: Regularly inspect all DC and AC connections for tightness. Loose connections can lead to power loss, overheating, and potential fire hazards.
- Heilsa rafhlöðu: Monitor your battery bank's health and charge level. A healthy battery system is essential for inverter performance.
- Geymsla: Ef inverterinn er geymdur í langan tíma skal ganga úr skugga um að hann sé aftengdur öllum aflgjöfum og geymdur á köldum, þurrum stað.
8. Bilanagreining
Ef þú lendir í vandræðum með inverterinn þinn skaltu skoða eftirfarandi algeng vandamál og lausnir:
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| No AC Output / Inverter Not Turning On | Loose DC connections, low battery voltage, öryggi sprungið, inverterinn slökktur. | Check DC cable connections and battery voltage. Ensure inverter switch is ON. Replace internal fuses if necessary (consult manual or qualified technician). |
| Overload Alarm / Red Fault LED | Connected load exceeds inverter's continuous or surge rating. | Reduce the total load connected to the inverter. Disconnect some appliances and restart the inverter. |
| Yfirhitaviðvörun | Inadequate ventilation, blocked cooling fans, high ambient temperature. | Ensure inverter is in a well-ventilated area. Clear any obstructions from cooling fans. Allow inverter to cool down before restarting. |
| Lágt binditage Viðvörun | Rafhlaða voltage er of lágt. | Recharge or replace the battery bank. Ensure battery cables are of adequate gauge and length. |
| GFCI Tripping | Jarðtenging greind í tengdu tæki eða raflögnum. | Disconnect all appliances from the GFCI outlets. Reset the GFCI. Reconnect appliances one by one to identify the faulty device. |
9. Tæknilýsing
| Forskrift | Gildi |
|---|---|
| Nafn líkans | PWRINV360012120W |
| Stöðugur kraftur | 3600 vött |
| Surge Power | 7200 vött |
| DC Input Voltage | 12 volt |
| AC Output Voltage | 120 Volt AC |
| Úttaksbylgjuform | Breytt sinusbylgja |
| Vottanir | ETL Certified to UL 458, CSA Standard C22.2 No. 107.1-01 |
| AC innstungur | Dual GFCI Outlets (20 Amp hver) |
| Additional AC Output | AC tengibúnaður |
| Þyngd hlutar | 9.04 pund |
| Vörumál | 14.5 x 6.62 x 5.6 tommur |
| Mælt er með notkun | Home, Office, RV, Cabin |
| Aflgjafi | Rafhlöðuknúið |
10. Ábyrgð og stuðningur
AIMS Power stands behind its products. This inverter comes with a 2 árs ábyrgð. All technical support, warranty claims, and sales inquiries are handled directly from our support center in Nevada, USA. For assistance, please refer to the contact information provided in your product packaging or visit the official AIMS Power websíða.