1. Inngangur
The Hioki CM3286 Clamp On Power Tester is a versatile instrument designed for precise measurement of electrical parameters. It is capable of measuring voltage, current, power, power factor, phase angle, reactive power, and frequency. Additionally, it can detect phase sequence on live lines within single-phase or three-phase circuits at any desired point. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your CM3286 device.
2. Öryggisupplýsingar
VIÐVÖRUN: Lesið allar öryggisviðvaranir og leiðbeiningar áður en þessi vara er notuð. Ef ekki er farið eftir viðvörunum og leiðbeiningunum getur það valdið raflosti, eldsvoða eða alvarlegum meiðslum.
- Fylgið alltaf öryggisreglum á hverjum stað og á landsvísu.
- Ekki nota tækið ef það virðist skemmt eða virkar ekki eins og það á að gera.
- Ensure the device is rated for the voltage and current levels you intend to measure.
- Wear appropriate personal protective equipment (PPE), such as insulated gloves and eye protection.
- Avoid touching live conductors with bare hands or non-insulated tools.
- Do not operate the device in wet environments or explosive atmospheres.
- Keep fingers behind the tactile barrier on the instrument during measurements.
- Disconnect the device from the circuit before opening the battery compartment.
3. Innihald pakka
Verify that all items listed below are present and undamaged upon opening the package:
- Hioki CM3286 Clamp On Power Tester Unit
- Prófunarleiðslur (rauðar og svartar)
- Burðartaska
- AAA rafhlöður (x2)
- Leiðbeiningar (þetta skjal)
4. Eiginleikar og íhlutir vörunnar

Figure 4.1: Hioki CM3286 Clamp On Power Tester (Overall View)
This image displays the complete Hioki CM3286 Clamp On Power Tester, showcasing its ergonomic design, the large clamp jaw for current measurement, and the clear digital display. The function dial and various control buttons are visible on the front panel.

Figure 4.2: Hioki CM3286 Clamp On Power Tester (Front Panel Detail)
This image provides a closer look at the front panel of the Hioki CM3286, highlighting the digital display, the rotary function dial with various measurement settings (e.g., W, Wh, V, A), and the control buttons such as SHIFT, HOLD, MAX/MIN, and RANGE. The input terminals for voltage measurement are also visible at the bottom.
Lykilhlutir:
- Clamp Kjálka: Notað til að mæla snertilausa riðstraum.
- Aðgerðarskífa: Selects the desired measurement mode (e.g., Voltage, Current, Power, Frequency).
- LCD skjár: Sýnir mælingar, einingar og vísa.
- Inntaksstöðvar: Til að tengja prófunarleiðslur fyrir magntage and other measurements.
- HOLD hnappur: Frystir núverandi skjálestur.
- MAX/MIN hnappur: Records maximum and minimum readings.
- RANGE hnappur: Manually selects the measurement range.
- SHIFT hnappur: Accesses secondary functions marked in blue on the dial.
5. Uppsetning
5.1. Uppsetning rafhlöðu
- Gakktu úr skugga um að slökkt sé á tækinu.
- Finndu rafhlöðulokið aftan á tækinu.
- Use a screwdriver (if necessary) to open the cover.
- Insert two (2) AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Settu hlífina yfir rafhlöðuhólfið aftur og festu það.
5.2. Fyrsta ræsing
After battery installation, turn the function dial from "OFF" to any measurement setting to power on the device. The display should illuminate, indicating readiness for use.
6. Notkunarleiðbeiningar
6.1. Kveikt/slökkt
- To power on, rotate the function dial from the "OFF" position to the desired measurement function.
- To power off, rotate the function dial back to the "OFF" position.
6.2. Mæling á riðstraumi (Clamp)
- Rotate the function dial to the "A" (Current) setting.
- Opnaðu clamp jaw by pressing the lever.
- Enclose only one conductor (live or neutral) within the clamp kjálki. Gakktu úr skugga um að kjálkinn sé alveg lokaður.
- Lestu núverandi gildi á LCD skjánum.
6.3. Binditage Mæling (V)
- Rotate the function dial to the "V" (Voltage) stilling.
- Connect the red test lead to the "V" input terminal and the black test lead to the "COM" input terminal.
- Connect the test leads in parallel across the circuit or component to be measured.
- Lestu binditage gildi á LCD skjánum.
6.4. Power Measurement (W, Wh, var, VA)
The CM3286 can measure various power parameters. Select the appropriate setting on the function dial (W for active power, Wh for energy, var for reactive power, VA for apparent power). Connect test leads for voltage og clamp the jaw around the current conductor as per the specific measurement method outlined in the full manual (not provided here, but implied by the device's capabilities).
6.5. Frequency Measurement (Hz)
Select the "Hz" setting on the function dial. Connect test leads across the circuit where frequency is to be measured, similar to voltage mæling.
6.6. Phase Sequence Detection
The device features a "Phase Detect" function. Refer to the detailed instructions in the complete manual for proper connection and interpretation of phase sequence on single-phase or three-phase circuits.
6.7. Using Buttons (HOLD, MAX/MIN, RANGE, SHIFT)
- HOLD: Press to freeze the current reading on the display. Press again to release.
- MAX/MIN: Press to enter Max/Min recording mode. The display will show the maximum or minimum value recorded since activation. Press again to cycle through Max, Min, and current readings.
- SVIÐ: Ýttu á til að skipta á milli sjálfvirkrar og handvirkrar mælikvarða. Í handvirkri mælikvarða skaltu ýta endurtekið á til að fletta í gegnum tiltæk svið.
- SHIFT: Press to access secondary functions indicated in blue text next to the primary function on the dial.
7. Viðhald
7.1. Þrif
Þurrkaðu tækið með mjúku, damp klút. Notið ekki slípiefni eða leysiefni. Gangið úr skugga um að tækið sé alveg þurrt áður en það er geymt eða notað aftur.
7.2. Skipt um rafhlöðu
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Follow the battery installation steps outlined in Section 5.1.
7.3. Geymsla
Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
8. Bilanagreining
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| Ekki kveikir á tækinu. | Rafhlöður sem eru tómar eða rangt settar í. | Athugið pólun rafhlöðunnar; skiptið um rafhlöður. |
| No reading on display. | Incorrect function selected; open circuit; test leads not connected properly. | Select correct function; ensure circuit is complete; check test lead connections. |
| "OL" or "OVER" displayed. | Measurement exceeds selected range or device maximum. | Select a higher range (if manual ranging) or ensure measurement is within device limits. |
| Ónákvæmar lestrar. | Low battery; environmental interference; damaged test leads. | Replace batteries; move away from strong electromagnetic fields; inspect and replace test leads if damaged. |
9. Tæknilýsing
| Parameter | Gildi |
|---|---|
| Gerðarnúmer | CM3286 |
| Vörumerki | Hioki |
| Stærðir pakka | 9.92 x 2.76 x 2.05 tommur |
| Þyngd hlutar | 0.45 kíló (15.87 únsur) |
| Rafhlöður | 2 AAA rafhlöður (meðfylgjandi) |
| Aflgjafi | Rafmagnstenging með snúru (Note: This refers to the type of power it measures, not its own power source. The device is battery-powered.) |
| Framleiðandi | Hioki |
| Dagsetning fyrst í boði | 20. ágúst 2020 |
10. Ábyrgð og stuðningur
For detailed warranty information, please refer to the warranty card included with your product or visit the official Hioki website. Hioki provides comprehensive customer support for its products.
If you encounter any issues not covered in this manual or require technical assistance, please contact Hioki customer support through their official channels. Ensure you have your product model number (CM3286) and purchase details ready when contacting support.
Athugið: Ábyrgðarskilmálar geta verið mismunandi eftir svæðum.