ABB XT1C 160

Notendahandbók fyrir ABB TMAX XT1C 160 rofa

Model: XT1C 160 | Brand: ABB

Inngangur

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB TMAX XT1C 160 Molded Case Circuit Breaker (MCCB). Please read this manual thoroughly before attempting any installation or operation.

Öryggisupplýsingar

WARNING: Electrical shock hazard. Only qualified personnel should install, operate, or maintain this device.

Vara lokiðview

The ABB TMAX XT1C 160 is a 3-pole fixed molded case circuit breaker with a thermomagnetic release, designed for protection against overloads and short circuits in electrical systems. It features front terminals for easy connection.

ABB TMAX XT1C 160 Molded Case Circuit Breaker with specifications visible

This image shows the ABB TMAX XT1C 160 circuit breaker. Key features visible include the ABB logo, the SACE Tmax branding, the 'off' position indicator, and the current rating adjustment dials (MED 106A, MAX 125A). The top section displays technical specifications such as rated operational voltage (Ue), rated ultimate short-circuit breaking capacity (Icu), and rated impulse withstand voltage (Uimp). The breaker is a 3-pole design with front terminals.

Tæknilýsing

ParameterGildi
FyrirmyndXT1C 160
Núverandi einkunn125 Amps
Fjöldi pólverja3
Aflrofi gerðStaðlað, hitasegulmagnað
Gerð uppsetningarDIN Rail festing
Rated Operational Voltage (Ue)690V AC, 500V DC
Rated Ultimate Short-Circuit Breaking Capacity (Icu)25kA @ 415VAC
Metið Impulse Standst Voltage (Uimp)8kV
ÚtgáfutegundThermomagnetic (TMD)
FlugstöðvarFraman
StaðlarIEC60947-2, NEMA AB1
FramleiðandiMYND
ASINB07JJL7XGD

Uppsetning

Fyrir uppsetningu: Ensure the power supply is disconnected and locked out according to safety procedures. Verify the circuit breaker's ratings match the application requirements.

Uppsetning

The XT1C 160 is designed for DIN rail mounting.

  1. Securely attach the DIN rail to the mounting surface in the electrical enclosure.
  2. Align the circuit breaker's rear clips with the DIN rail.
  3. Press firmly until the breaker clicks into place, ensuring it is securely fastened.

Raflögn

Connect the power supply and load cables to the designated front terminals.

Rekstur

Kveikt/slökkt

The circuit breaker has a toggle handle for manual operation.

Current Adjustment (TMD Release)

The thermomagnetic release allows for adjustment of the rated current (In) and instantaneous trip setting.

Viðhald

Regular maintenance ensures the longevity and reliable operation of the circuit breaker. Always disconnect power before performing any maintenance.

Úrræðaleit

VandamálMöguleg orsökLausn
Breaker ferð oftOverload or short circuit in the protected circuit.Identify and remove the overload. Check for short circuits in the connected circuit using appropriate testing equipment.
Breaker does not reset after trippingPersistent fault in the circuit or internal damage to the breaker.Ensure the fault is completely cleared. If it still doesn't reset, the breaker may be damaged internally and require replacement by a qualified technician.
Overheating at terminalsLoose connections or undersized wiring for the load.Disconnect power and tighten terminal screws to the specified torque. Verify wire gauge is appropriate for the maximum current.
Breaker does not trip on faultBreaker malfunction or incorrect rating for the application.Immediately disconnect power. Do not use the breaker. It must be inspected and potentially replaced by a qualified professional. Verify the breaker's ratings match the system requirements.

Ábyrgð og stuðningur

For detailed warranty information and technical support, please refer to the official ABB website or contact your authorized ABB distributor. Keep your purchase receipt for warranty claims.

Framleiðandi: ABB

ASIN: B07JJL7XGD

Date First Available: July 3, 2019

Fyrir frekari aðstoð, heimsækja ABB verslun á Amazon.

Tengd skjöl - XT1C 160

Preview ABB SACE Tmax for Special Applications: Circuit Breakers & Switch-Disconnectors
Explore ABB's SACE Tmax range of molded case circuit-breakers and switch-disconnectors for special applications. Offering high breaking capacity, flexibility, and advanced protection compliant with UL and IEC standards for DC and AC systems up to 1500V DC and 1150V AC.
Preview Uppsetning og tæknilegar upplýsingar um ABB Tmax T5 rofa
Ítarlegar tæknilegar upplýsingar, víddarteikningar og uppsetningarleiðbeiningar fyrir ABB Tmax T5 rofa, þar á meðal ýmsar gerðir eins og PR221DS.
Preview ABB SACE Tmax XT vörulisti: Lágt magntage Mótað hylki rofar
Skoðaðu ABB SACE Tmax XT seríuna, nýjustu línu lágrúmmálsvéla.tagE-mótaðir rofar með háþróaðri afköstum, tengingu, auðvelda notkun og öflugri vörn fyrir fjölbreytt iðnaðar- og viðskiptaforrit.
Preview Uppsetningarleiðbeiningar fyrir SACE Tmax XT rofa
Ítarlegar uppsetningarleiðbeiningar og ráðlagðar aðstæður fyrir ABB SACE Tmax XT rofa, sem ná yfir AC og DC notkun, raflögn, víddargögn og prófunaraðferðir fyrir útleysingar.
Preview ABB SACE® Tmax® XT mótaðar rofar: Leiðbeiningar um dreifingaraðilaflutninga frá Spectra™
Þessi handbók um dreifingaraðilaflutninga frá ABB veitir ítarlegt yfirlitview af SACE® Tmax® XT mótuðu rofunum, þar sem ítarleg eru eiginleikar þeirra, notkun og kostir. Það leiðbeinir notendum um flutning frá Spectra™ seríunni sem er að hætta, býður upp á birgðaaðferðir, telur upp fylgihluti og útskýrir pöntunarfyrirkomulag vöru. Nauðsynlegt fyrir rafdreifingaraðila og forskriftaraðila.
Preview ABB SACE Tmax T kynslóð: Lágt magntagTækniskrá fyrir mótaða rofa (250A-1600A)
Skoðaðu ABB SACE Tmax T Generation línuna af lágvolkumtagMótaðir rofar, hannaðir fyrir öfluga rafmagnsvörn og áreiðanlega aflsdreifingu frá 250 A til 1600 A. Þessi tækniskrá lýsir eiginleikum, forskriftum og notkunarmöguleikum.