TRUPER 13499

Truper 13499 PRES-1/3T Pressure Booster Pump User Manual

Model: 13499 / PRES-1/3T

1. Inngangur

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Truper 13499 PRES-1/3T 1/3 HP Pressure Booster Pump. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Öryggisupplýsingar

Fylgdu alltaf eftirfarandi öryggisráðstöfunum:

3. Vöruhlutir

The Truper 13499 PRES-1/3T Pressure Booster Pump includes the main pump unit, an integrated pressure switch, and power cord with an on/off switch. Refer to the image below for a visual representation of the pump and its key components.

Truper 13499 PRES-1/3T Pressure Booster Pump

Mynd 1: Truper 13499 PRES-1/3T Pressure Booster Pump. This image shows the complete pump assembly, including the orange motor housing, the dark gray pump body, brass fittings for water inlet and outlet, and the integrated flow switch with an arrow indicating water flow direction. The power cord with an inline on/off switch is also visible.

Lykilþættir:

4. Uppsetning og uppsetning

Rétt uppsetning er lykilatriði fyrir afköst og endingu dælunnar.

  1. Staðsetning:
    • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
    • Ensure the pump is placed on a stable, level surface to minimize vibration.
    • Allow adequate space around the pump for ventilation and maintenance access.
  2. Pípulagnir:
    • Connect the pump to the water supply line using appropriate plumbing fittings. Ensure all connections are watertight.
    • Observe the flow direction indicated by the arrow on the flow switch (Figure 1). The pump must be installed in line with the water flow.
    • Use flexible connectors to reduce vibration transmission to the plumbing system.
    • Install shut-off valves on both the inlet and outlet sides of the pump for easier maintenance.
  3. Rafmagnstenging:
    • Ensure the power outlet is properly grounded and matches the pump's electrical requirements (127 V - 60 Hz).
    • Plug the pump's power cord into the grounded outlet.
    • Do not use extension cords unless absolutely necessary, and ensure they are rated for the pump's power requirements.
  4. Undirbúningur dælunnar:
    • Before initial operation, ensure the pump is filled with water to prevent dry running. Open a faucet downstream to allow air to escape.
    • Once water flows steadily from the faucet, close it. The pump is now primed.

5. Notkunarleiðbeiningar

The Truper 13499 PRES-1/3T pump operates automatically based on water flow.

  1. Upphafleg gangsetning:
    • After installation and priming, ensure the inline switch on the power cord is in the "OFF" position.
    • Stingdu dælunni í viðeigandi rafmagnsinnstungu.
    • Switch the inline power switch to the "ON" position. The pump will remain off until water flow is detected.
  2. Sjálfvirk aðgerð:
    • When a water outlet (e.g., faucet, shower) is opened, the flow switch detects water movement.
    • The pump automatically starts, boosting water pressure.
    • When the water outlet is closed, the flow stops, and the pump automatically shuts off after a short delay.
  3. Vinnuferill:
    • The pump is designed for intermittent use: 50 minutes of work followed by 20 minutes of rest.
    • The daily maximum operating time is 6 hours. Adhering to this duty cycle will prolong the pump's lifespan.

6. Viðhald

Reglulegt viðhald tryggir bestu mögulegu afköst og lengir líftíma dælunnar.

Warning: Always disconnect the pump from the power supply before performing any maintenance.

7. Bilanagreining

This section addresses common issues you might encounter with your pressure booster pump.

VandamálMöguleg orsökLausn
Dælan fer ekki í gang.Engin aflgjafi.
Inline switch is OFF.
No water flow detected.
Athugaðu rafmagnsinnstungu og rofa.
Turn inline switch to ON.
Open a water outlet to initiate flow. Ensure pump is primed.
Dælan gengur stöðugt.Leak in plumbing system.
Flow switch malfunction.
Constant low water flow.
Check all connections for leaks and repair.
Hafðu samband við hæft þjónustufólk.
Ensure all outlets are fully closed.
Insufficient pressure boost.Dælan ekki rétt grunnuð.
Inlet water pressure too low.
Obstruction in plumbing.
Endurræstu dæluna.
Ensure minimum input pressure of 0.72 PSI is met.
Inspect plumbing for blockages.
Dælan er hávær eða titrar óhóflega.Loft í kerfinu.
Laus festing.
Internal component wear.
Re-prime the pump to remove air.
Ensure pump is securely mounted on a stable surface.
Hafðu samband við hæft þjónustufólk.

8. Tæknilýsingar

EiginleikiForskrift
Fyrirmynd13499 / PRES-1/3T
Kraftur1/3 HP (248 W)
Voltage - Tíðni127 V - 60 Hz
Hámarksflæði15 gal/min (27 L/min) / 60 Liters Per Minute
Minimum Input Pressure0.72 PSI
Hámarksþrýstingur17 PSI
Vinnuferill50 min. work per 20 min. rest
Daily Maximum Operation6 klst
EfniÁl casing
Þyngd9 lb (4.3 Kg) / 10.36 pounds (shipping)
Dimensions (B x H x W)5 1/8" x 11 13/16" x 6 5/16" (13 x 30 x 16 cm) / 7.09 x 5.91 x 5.91 inches (product)
Water Outlets SupportedAllt að 3 samtímis
Tegund aðgerðaOn demand (Autostop switch)

9. Ábyrgð og stuðningur

For warranty information or technical support, please refer to the documentation included with your purchase or contact Truper customer service. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official Truper websíðuna eða hafið samband við viðurkennda þjónustumiðstöðvar þeirra.