1. Inngangur
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Cata UC-10 Bathroom Exhaust Fan. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and adherence to these instructions will ensure optimal performance and longevity of the product.
2. Öryggisupplýsingar
Fylgið alltaf eftirfarandi öryggisráðstöfunum til að draga úr hættu á eldsvoða, raflosti eða meiðslum.
- Rafmagnsöryggi: Ensure the power supply is disconnected before installation, maintenance, or cleaning. All electrical wiring must be performed by a qualified electrician and comply with local regulations.
- Uppsetning: Install the fan in accordance with the instructions provided. Do not install in areas where temperatures exceed 40°C. Ensure proper ventilation and clearance around the unit.
- Notkun: Þetta tæki er ekki ætlað til notkunar af einstaklingum (þar á meðal börnum) með skerta líkamlega, skynræna eða andlega getu, eða skort á reynslu og þekkingu, nema þeir hafi fengið eftirlit eða leiðbeiningar um notkun tækisins af einstaklingi sem ber ábyrgð á öryggi þeirra. .
- Viðhald: Only use original spare parts for repairs. Do not attempt to modify the fan. Regular cleaning is recommended to maintain performance.
3. Vöru lokiðview
The Cata UC-10 is a high-efficiency bathroom exhaust fan designed for effective ventilation, featuring an extra-flat design, low noise operation, and adjustable speed settings. It includes a humidity sensor (Hygro) and a timer function for automated control.
3.1 Helstu eiginleikar
- Extra-Flat Design: Modern and discreet aesthetic.
- Very Silent Operation: Minimum sound level of 26 dB(A).
- Mikil orkunýtni: Maximum power consumption of 8 W.
- Stillanlegur hraði: Six selectable speed levels for optimal airflow control.
- Humidity Sensor (Hygro): Automatically activates the fan based on ambient humidity levels.
- Tímamælir aðgerð: Adjustable run-on timer after activation.
- Bakdrag Damper: Prevents unwanted air entry when the fan is off.
- Hitavörn: Ensures safe operation up to 40°C ambient temperature.
- IP-44 Rated & Double Insulated: Provides protection against splashing water and electrical hazards.
3.2 Íhlutir
The Cata UC-10 fan unit typically includes the main fan body, a removable front cover, and necessary electrical cabling for installation.

Mynd 1: Framan view of the Cata UC-10 Bathroom Exhaust Fan. This image displays the fan's white, extra-flat design with its central impeller visible through the protective grille.

Mynd 2: Hallandi framhlið view of the Cata UC-10 fan, highlighting its compact and modern aesthetic suitable for various bathroom decors.

Mynd 3: Hlið view of the Cata UC-10 fan, showing the depth of the unit and the exhaust duct connection point.
4. Uppsetning og uppsetning
Installation of the Cata UC-10 fan requires electrical knowledge and should be performed by a qualified professional. The fan is designed for wall mounting.
4.1 Mál

Mynd 4: Technical diagram illustrating the dimensions of the Cata UC-10 fan. The front panel measures 150x150 mm, with a depth of 18.5 mm. The exhaust duct has a diameter of 100 mm and a length of 77.5 mm.
4.2 Uppsetningarskref (almennar leiðbeiningar)
- Undirbúningur: Disconnect power at the main circuit breaker. Choose a suitable wall mounting location, ensuring adequate space for the fan and ducting.
- Uppsetning: Create an opening in the wall according to the fan's duct diameter (100 mm). Secure the fan body to the wall using appropriate fasteners.
- Rúmgangur: Connect suitable ducting from the fan's exhaust outlet to the exterior. Ensure ducting is sealed to prevent air leakage.
- Raflögn: Connect the electrical cable to the fan's terminal block. Ensure correct polarity and secure all connections. The fan operates on 220-240V, 50/60Hz.
- Lokaþing: Attach the front cover securely to the fan body.
- Próf: Restore power and test the fan's operation, including the timer and humidity sensor functions.
5. Notkunarleiðbeiningar
The Cata UC-10 fan offers automated and adjustable operation modes.

Mynd 5: Diagram illustrating the adjustable speed, humidity sensor (Hygro), and timer settings of the Cata UC-10 fan.
5.1 Stillanlegur hraði
The fan features six adjustable speed levels, allowing you to optimize airflow and noise levels according to your needs. The available speeds range from 1050 RPM to 2220 RPM. Consult the internal adjustment mechanism (typically potentiometers or switches accessible after removing the front cover) to select the desired speed setting.
5.2 Humidity Sensor (Hygro)
The integrated humidity sensor automatically activates the fan when the ambient humidity exceeds a preset threshold. This threshold can typically be adjusted (e.g., from 30% to 80% relative humidity) using a control knob or potentiometer located inside the fan unit. The fan will run until the humidity level drops below the set point.
5.3 Tímamæliraðgerð
The timer function allows the fan to continue operating for a set period after it has been manually switched off or after the humidity level has dropped below the sensor's threshold. The timer duration is adjustable, commonly offering settings such as 3, 5, 10, 15, or 20 minutes. This setting is usually adjusted via a control knob or potentiometer within the fan unit.
6. Viðhald
Regular maintenance ensures the efficient and safe operation of your Cata UC-10 fan.
6.1 Þrif
- Aftengdu rafmagn: Always ensure the power supply to the fan is disconnected before cleaning.
- Fjarlægðu framhliðina: Carefully detach the extra-flat front cover.
- Hreinsir íhlutir: Notaðu mjúkan, damp cloth to wipe down the front cover and the fan blades. Avoid using abrasive cleaners or solvents. Ensure no water enters the electrical components.
- Settu saman aftur: Once all parts are dry, reattach the front cover securely.
It is recommended to clean the fan at least once every six months, or more frequently in dusty or high-humidity environments.
7. Bilanagreining
If you encounter issues with your Cata UC-10 fan, refer to the following common problems and solutions:
| Vandamál | Möguleg orsök | Lausn |
|---|---|---|
| Viftan kviknar ekki. | Engin aflgjafi. Gölluð raflögn. Humidity sensor not triggered. Tímamælir ekki stilltur. | Check circuit breaker and power connection. Verify wiring connections (consult an electrician). Increase humidity or manually activate. Adjust timer settings. |
| Viftan er óhóflega hávær. | Dirty fan blades. Laus festing. Stífla í loftrásum. | Clean fan blades (see Maintenance). Ensure fan is securely mounted. Athugið hvort einhverjar stíflur séu í loftstokkunum. |
| Poor air extraction. | Blocked ducting. Dirty fan blades. Rangt hraðastilling. | Clear any obstructions in the duct. Hreinsið viftublöð. Stilltu á meiri hraða. |
| Humidity sensor not working. | Sensor setting too high. Bilun í skynjara. | Adjust the humidity threshold to a lower percentage. Ef vandamálið er viðvarandi skaltu hafa samband við þjónustudeild. |
If the problem persists after attempting these solutions, please contact Cata customer support or a qualified technician.
8. Tæknilýsing
| Eiginleiki | Forskrift |
|---|---|
| Fyrirmynd | UC-10 (1200200) |
| Vörumerki | Cata |
| Tegund | Útblástursvifta á baðherbergi |
| Gerð uppsetningar | Veggfesting |
| Aflgjafi | Rafmagn með snúru |
| Voltage / Tíðni | 220-240V, 50/60Hz |
| Hámarks orkunotkun | 8 W |
| Hámarks loftflæði | 110 m³/klst |
| Minimum Noise Level | 26 dB(A) |
| Viftuhraði | Adjustable, up to 2220 RPM (6 levels) |
| Þvermál úttaks | 100 mm |
| Front Panel Dimensions (W x H) | 150 mm x 150 mm |
| Front Panel Depth | 18.5 mm |
| Lengd rásarinnar | 77.5 mm |
| Þyngd | 0.65 kg |
| Efni | Plast (Kunstefni) |
| IP einkunn | IP-44 |
| Einangrunarflokkur | Double Insulation (Class B) |
| Hitavörn | Up to 40°C ambient temperature |
| Sérstakir eiginleikar | Timer, Humidity Sensor (Hygro), Adjustable Speed, Backdraft Damper |
9. Ábyrgð og stuðningur
Cata products are manufactured to high-quality standards and are covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official Cata webvefsíðu fyrir ítarlegar ábyrgðarskilmála.
For technical assistance, spare parts, or warranty claims, please contact your local dealer or Cata customer service. Ensure you have your product model number (UC-10, 1200200) and proof of purchase available when contacting support.