Itron YES030151

Itron EDF 60A 230V Selective Circuit Breaker User Manual

Model: YES030151

Inngangur

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Itron EDF 60A 230V Selective Circuit Breaker. Please read this manual thoroughly before use and retain it for future reference.

The Itron EDF 60A 230V Selective Circuit Breaker is designed to protect your electrical installation from overloads and short circuits. It is a single-phase, 2-pole device operating at 230 volts with a 500 mA differential current. Its selective nature allows for adjustable current settings at 30A, 45A, and 60A, ensuring compliance with NF C 62 411 standards.

Vara lokiðview

Itron EDF 60A 230V Selective Circuit Breaker

Figure 1: Itron EDF 60A 230V Selective Circuit Breaker. A white, rectangular electrical circuit breaker with the Itron logo and specifications printed on its side. It features a blue 'Test' button and a toggle switch.

Helstu eiginleikar:

Uppsetning og uppsetning

Uppsetning ætti aðeins að vera framkvæmd af löggiltum rafvirkja í samræmi við gildandi rafmagnsreglugerðir og reglugerðir á hverjum stað.

Öryggisráðstafanir:

Uppsetningarskref:

  1. Identify the appropriate mounting location on an EDF subscriber circuit breaker plate or a meter/circuit breaker plate.
  2. Mount the circuit breaker securely onto the DIN rail. The mounting type is DIN rail mounting.
  3. Connect the incoming phase and neutral conductors to the designated terminals (2 poles).
  4. Connect the outgoing phase and neutral conductors to the protected circuit.
  5. Gakktu úr skugga um að allar tengingar séu þéttar og öruggar.
  6. Set the desired current rating (30A, 45A, or 60A) using the adjustment mechanism on the device. Refer to your electricity provider's specifications for the correct setting.

Notkunarleiðbeiningar

Kveikt/slökkt:

Testing the Differential Function:

It is recommended to test the differential function regularly (e.g., monthly) to ensure proper operation.

  1. Ensure the circuit breaker is in the 'I' (ON) position.
  2. Press the blue 'Test' button located on the front of the device.
  3. The circuit breaker should trip, moving the toggle switch to the 'O' (OFF) position.
  4. To reset, push the toggle switch fully down, then back up to the 'I' (ON) position.
  5. If the circuit breaker does not trip during the test, contact a qualified electrician for inspection and replacement if necessary.

Viðhald

The Itron EDF 60A 230V Selective Circuit Breaker requires minimal maintenance. Regular visual inspections and functional testing are recommended.

Venjulegar athuganir:

Do not attempt to open or repair the circuit breaker yourself. Refer all servicing to qualified personnel.

Úrræðaleit

VandamálMöguleg orsökLausn
Rofinn sleppir oft.Overload, short circuit, or ground fault in the protected circuit.
  • 1. Disconnect appliances from the circuit.
  • 2. Endurstilltu aflrofann.
  • 3. If it trips again, there may be a short circuit or ground fault. Contact a qualified electrician.
  • 4. Ensure the total load does not exceed the circuit breaker's rating.
Circuit breaker does not trip when 'Test' button is pressed.Faulty differential mechanism or internal damage.
  • 1. Do not use the circuit breaker.
  • 2. Contact a qualified electrician for inspection and replacement.
Circuit breaker feels hot to the touch.Ofhleðsla, lausar tengingar eða innri bilun.
  • 1. Immediately turn off the main power supply.
  • 2. Contact a qualified electrician for inspection.

Tæknilýsing

EiginleikiGildi
VörumerkiItron
GerðarnúmerJÁ030151
ASINB07Z4TDBDN
Metið núverandi60 A (Adjustable to 30 A, 45 A)
Mismunandi straumur500 mA
Voltage230 V
Fjöldi pólverja2
Gerð uppsetningarDIN rail uppsetning
Mál (L x B x H)20.2 x 8 x 7.3 cm
Þyngd400 grömm
FylgniNF C 62 411

Upplýsingar um ábyrgð

Itron products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your local Itron distributor. Keep your proof of purchase for warranty claims.

Stuðningur og samband

For technical assistance, troubleshooting beyond this manual, or spare parts information, please contact Itron customer support or your authorized dealer.

Manufacturer: Itron

Fyrir frekari upplýsingar, heimsækja Itron brand page.

Tengd skjöl - JÁ030151

Preview Itron Cellular 500W Remote Module Installation Guide
Installation guide for the Itron Cellular 500W Remote Module (ECW-1700-002), detailing its features, operating modes, and installation procedures for water meters and registers.
Preview Itron 100W+ ERT Module Installation Guide: Pit and Remote Mount
Comprehensive installation guide for the Itron 100W+ ERT Module, detailing procedures for both pit and remote-mount installations, setup, configuration, and troubleshooting for utility metering applications.
Preview Itron FCT Field Configuration Tool Notendahandbók
User guide for the Itron Field Configuration Tool (FCT), providing installation, operation, and compliance information for utility field technicians.
Preview Itron EquaScan eHCA Electronic Heat Cost Allocator - Product Overview og Tæknigögn
Detailed information on the Itron EquaScan eHCA electronic heat cost allocator, featuring its technical specifications, communication interface, display functions, and dimensions for utility and building management.