Leviton DOS02-LW

Leviton DOS02-LW Motion Sensor Light Switch Instruction Manual

Model: DOS02-LW

Inngangur

The Leviton DOS02-LW Motion Sensor Light Switch is designed to automatically turn lights on and off based on motion and occupancy. This single-pole device offers convenient hands-free lighting control and can be installed with or without a neutral wire, requiring a ground connection. It is suitable for various applications such as pantries, closets, laundry rooms, and basements, helping to conserve energy by ensuring lights are not left on unintentionally.

Eiginleikar

  • Sjálfvirk aðgerð: Turns lights on/off based on motion, providing a 180° field-of-view og 900 sq. ft.
  • Auðveld uppsetning: Grannur atvinnumaðurfile fits most wallboxes.
  • Sveigjanleg raflögn: Can be installed with or without a neutral wire; a ground connection is required.
  • Fjölhæfar stillingar: Can be set for occupancy (auto-on/auto-off) or vacancy (manual-on/auto-off) switching.
  • Hleðslusamhæfi: Supports 150W LED/CFL, 250W Incandescent/Halogen, 200VA Magnetic Low Voltage, 250VA Electronic Low Voltage, 2A Resistive loads.
  • Sérhannaðar útlit: Easily change the color using DOSKT faceplates (sold separately).
  • Dagsbirtuuppskera: Lights will not turn on if ample daylight is present in the space.

Hvað er í kassanum

  • One Leviton Motion Sensor Switch DOS02-LW, White

Öryggisupplýsingar

WARNING: TO AVOID FIRE, SHOCK, OR DEATH, ALWAYS TURN OFF POWER AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING.

If you are unsure about any part of the instructions or are not comfortable or familiar with electrical wiring, contact a licensed electrician. This device is designed for use with Copper or Copper-Clad wire only. Do not mount near a heat source, in drafty areas, or in motion-heavy areas where unintended motion may trigger the sensor.

Verkfæri sem þarf til uppsetningar

  • Flathead skrúfjárn
  • Phillips höfuð skrúfjárn
  • Rafvirkjatöng
  • Vír strippari
  • Rafmagns borði
  • Handfesta hljóðstyrkurtage prófanir
  • Properly Sized Wire Connectors

Uppsetning

Installation typically takes approximately 15 minutes. Always ensure power is off at the circuit breaker before beginning. The device replaces an existing single-pole switch.

1. Undirbúa fyrir uppsetningu

  1. Turn off power at the circuit breaker or fuse for the switch you are replacing.
  2. Remove the existing switch plate and unscrew the old device from the wall box.
  3. Carefully pull the device out until you can clearly see the wires.
  4. Notaðu binditage tester to confirm no power is present in the box.
  5. Disconnect all wiring from the old device and remove it.
  6. Straighten and separate each wire in the wall box. Ensure no exposed metal ends are touching.

2. Identify Wiring Configuration

The Leviton DOS02-LW can be wired with or without a neutral wire. Identify if a neutral wire (typically white) is present in your wall box. The neutral wire may be capped off with a wire connector.

Wiring diagram showing connections for Leviton motion sensor switch

Image: Wiring diagram for the Leviton motion sensor switch, illustrating the various wire connections.

3. Tenging tækisins

The device features pre-stripped lead wires. Gently pull on the insulation to remove the pre-stripped section. Twist the exposed stranded copper wire in a clockwise direction to prepare it for termination.

Video: Official Leviton installation guide for Decora Occupancy and Vacancy Sensors, including models DOS02, DVS02, DOS05, and DVS05. This video provides detailed visual instructions for wiring and setup.

Wiring without a Neutral Wire:

  • Connect the green and yellow ground lead wire from the device, along with the green sleeve ground wire, to the ground wire in the wall box using a properly sized wire connector.
  • Connect the black lead wires from the device to the black line and load wires in the wall box. The line and load wires can be wired interchangeably.
  • For DOS05 or DVS05 models (not DOS02-LW), cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

Wiring with a Neutral Wire:

  • Remove the green sleeve from the white wire on the device. Connect this white wire to the white neutral wire(s) in the wall box using a properly sized wire connector.
  • Connect the green and yellow ground lead wire from the device to the ground wire in the wall box using a properly sized wire connector.
  • Connect the black lead wires from the device to the black line and load wires in the wall box. The line and load wires can be wired interchangeably.
  • For DOS05 or DVS05 models (not DOS02-LW), cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

Video: Leviton's Green Flex Sleeve feature, explaining its use for wiring with or without a neutral wire.

4. Uppsetning tækisins

  1. Gently bend the wires and push them into the wall box.
  2. Screw the sensor into the wall box.
  3. Install the wall plate (sold separately).

Rekstur

After installation and restoring power, the sensor will undergo a warm-up period (typically 10-20 seconds). For DOS02-LW, lights will automatically turn on with the first motion detected after the warm-up period. You can also manually press the push pad to turn lights on or off.

Leviton DOS02-LW Motion Sensor Light Switch controlling a single light bulb

Image: The Leviton DOS02-LW Motion Sensor Light Switch demonstrating single pole control of a light.

Umsókn Examples

Examples of where to use the motion sensor switch: mudrooms, closets, and garages

Mynd: Sjónrænt dæmiamples of ideal locations for the motion sensor switch, including mudrooms, closets, and garages.

The sensor provides hands-free lighting, which is particularly useful in areas where you may enter with your hands full or where lights are often left on unintentionally.

Graphic illustrating 'Hands-Free Lighting' with a hand icon

Image: A graphic highlighting the 'Hands-Free Lighting' benefit of the motion sensor switch.

Forritun og stillingar

The default settings for the sensor are a 10-minute time-out timer, medium range field-of-view, and medium ambient light setting. These settings can be adjusted to suit your specific needs.

Illustration showing hands pressing the motion sensor switch to change settings without tools

Image: The motion sensor switch being pressed to change settings, indicating no tools are required for adjustment.

Refer to the detailed product instruction sheet for specific steps on how to change the time-out timer, sensitivity/coverage, and ambient light settings.

Úrræðaleit

If the lights do not operate as expected after installation, refer to the troubleshooting section in the full instruction sheet. Common issues and adjustments include:

  • Lights do not operate with push pad and RED indicator does not blink when motion is present: Verify wiring connections to the sensor.
  • Lights do not switch ON when motion is detected (DOS02): Motion may be beyond sensing range (move closer to switch). Adjust the light level lower (Option 3, 2, 1 or disable). If the RED light is blinking, it indicates motion. If it is blinking and the load is not turning ON, it could be due to ambient light OR check to make sure that the OCC/VAC switch is in OCC position.
  • Lights always stay ON: Check time delay settings and compare to how long the lights stay ON. Make sure no motion occurs in the coverage area for the time selected by covering the lens. Check that the switch is not installed near a heat source (like stove, lights, heat vents) or detecting motion from an adjacent area (like hallway traffic) and if it is, relocate it.
  • Lights do not turn ON (DVS02): Make sure that control is installed correctly. Make sure the power is ON. Check to make sure the light bulb is functional.

Tæknilýsing

ForskriftGildi
NotkunarhamurSjálfvirkt eða handvirkt
Núverandi einkunn2 Amps
Operation Voltage120 volt
Tegund tengiliðaVenjulega opið
Tegund tengisCrimp
FlugstöðVírleiðir
Stærðir hlutar (L x B x H)1.38 x 1.73 x 4.13 tommur
Rás hringrásarEinn stöng
Gerð stýrisbúnaðarVeltisrofi
Hafðu samband við efniBrass
International Protection RatingIP00
Fjöldi staða2
Lægra hitastig70 gráður á Fahrenheit
Efri hitastigseinkunn100 gráður á Fahrenheit
Gerð stjórnandaRofi fyrir hreyfiskynjara
EftirlitsaðferðSkynjari
TengireglurInnrautt
LiturHvítur
Hvaðtage250 vött
Þyngd hlutar0.01 aura

Viðhald

To clean the device, wipe with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the sensor lens is clear of dust and obstructions for optimal performance.

Ábyrgð og stuðningur

For warranty information or technical support, please refer to the documentation included with your product or visit the official Leviton websíða. Geymdu kaupkvittun þína fyrir ábyrgðarkröfur.

Tengd skjöl - DOS02-LW

Preview Leviton DOS05/DVS05 Wide-View Motion Activated Light Control Installation Guide
Comprehensive installation instructions and operation guide for Leviton DOS05 and DVS05 Wide-View Motion Activated Light Controls. Learn about wiring, programming, sensing coverage, and troubleshooting.
Preview Uppsetning og notkun Leviton DOS05/DVS05 hreyfistýrðrar ljósstýringar
Ítarleg leiðbeiningar um uppsetningu og notkun Leviton DOS05 og DVS05 Wide View Hreyfistýrðar ljósastýringar, sem ná yfir einpóla og þrípóla notkun, forritun og bilanaleit.
Preview Leviton DOS02/DVS02 Motion Activated Light Control Installation and Operation Manual
Detailed instructions for installing and operating Leviton's DOS02 and DVS02 Single Pole Wide View Motion Activated Light Controls, including wiring, programming, and troubleshooting.
Preview Leviton DOS15/DVS15 hreyfistýrð ljósstýring: Uppsetningar- og notkunarleiðbeiningar
This guide provides detailed instructions for installing and operating Leviton's DOS15 and DVS15 motion-activated light controls. It covers wiring configurations for single-pole and 3-way setups, programming features like timer, sensitivity, and ambient light, advanced modes, and troubleshooting common issues. Includes diagrams and specifications for optimal use.
Preview Leviton ODS15-IDx hönnuður veggrofa fyrir viðveruskynjara uppsetningarleiðbeiningar
Ítarlegar uppsetningarleiðbeiningar og notendahandbók fyrir Leviton ODS15-IDx Designer veggrofa, sem fjallar um eiginleika, uppsetningu, forritun, notkun og bilanaleit fyrir uppsetningar á einum og mörgum stöðum.
Preview Leviton Decora veggrofinn PIR viðveruskynjarar PR150-1L/PR180-1L Vörulýsing
Ítarlegar upplýsingar og eiginleikar fyrir Decora veggrofa Leviton með PIR-viðveruskynjurum (PR150-1L og PR180-1L), þar á meðal notkun, notkun, uppsetningu og tæknilegar upplýsingar um orkusparandi lýsingarstýringu.