1. Yfirview
The SINOTIMER TM618 timer module is designed to automatically control the power supply to various electrical apparatus, such as streetlights, neon signs, billboards, and other appliances, based on a preset time schedule. This digital timer switch features a rechargeable internal battery to maintain program settings during power outages.

Mynd 1.1: Framan view of the TM618 Timer Module.
2. Helstu eiginleikar
- Fyrirferðarlítil og plásssparandi hönnun.
- Engineered with advanced digital timing technology.
- High functionality for precise time control.
- Built-in rechargeable battery for program retention.
- Multiple ON/OFF programs for weekly scheduling.
3. Uppsetning og uppsetning
3.1. Raflið
Proper wiring is crucial for the safe and correct operation of the TM618 timer module. Refer to the diagram below for connection details. Ensure power is disconnected before performing any wiring.

Figure 3.1: Wiring Terminals and Specifications.
- Input (200-250VAC): Connect your main power supply to terminals 1 and 2.
- Output (16 AMP / 250VAC, 20 AMP @30 VDC): Terminals 3, 4, and 5 are for the controlled output. Terminal 3 is common, Terminal 4 is normally open (NO), and Terminal 5 is normally closed (NC). Connect your load to the appropriate terminals based on your application (e.g., between 3 and 4 for normally off, turning on when timed).
3.2. Upphafleg ræsing og rafhlaða
Upon initial power-up, the timer's internal rechargeable battery (40mAh) will begin charging. This battery saves your programmed settings during power interruptions. Allow the unit to be powered for at least 30 minutes for the battery to gain sufficient charge before programming or disconnecting power.

Figure 3.2: Internal 40mAh Rechargeable Battery.

Figure 3.3: TM618 Operating Voltage (220V AC shown).
4. Notkunarleiðbeiningar
The TM618 timer allows for precise control with up to 16 ON/OFF programs per day or week. The buttons on the front panel are used for setting the time and programs.

Figure 4.1: Timer Module with Manual.
4.1. Stilling núverandi tíma
- Ýttu á Klukka hnappinn og haltu honum inni.
- Á meðan haldið er Klukka, ýttu á VIKA til að stilla núverandi vikudag.
- Á meðan haldið er Klukka, ýttu á Klukkutími til að stilla núverandi klukkustund.
- Á meðan haldið er Klukka, ýttu á MIN til að stilla núverandi mínútu.
- Slepptu Klukka hnappinn. Tíminn er nú stilltur.
4.2. Forritun á kveikju- og slökkvunartímum
Tímastillirinn styður allt að 16 KVEIKJA/SLÖKKA forrit. Hvert forrit samanstendur af KVEIKJA tíma og SLÖKKA tíma.
- Ýttu á PROG hnappinn einu sinni. Skjárinn mun sýna „1 ON“.
- Ýttu á VIKA til að velja dag(a) fyrir þessa dagskrá (t.d. MÁN, ÞRI, MIÐ, FIM, FÖS, LAU, SUN, eða samsetningar eins og MÁN-FÖS, LAU-SU, MÁN-LAU, o.s.frv.).
- Ýttu á Klukkutími til að stilla æskilega KVEIKTU klukkustund.
- Ýttu á MIN til að stilla æskilega ON-mínútu.
- Ýttu á PROG aftur. Skjárinn mun sýna „1 SLÖKKT“.
- Endurtakið skref 2-4 til að stilla SLÖKKUNARDAG, klukkustund og mínútu fyrir þetta forrit.
- Ýttu á PROG to advance to the next program ("2 ON") or to exit programming mode if no more programs are needed.
- To clear a program, press MYNDATEXTI á meðan viewing the specific ON or OFF program you wish to clear.
4.3. Handvirk hnekkja
Ýttu á HANDBÓK button to cycle through different operating modes:
- SJÁLFvirkt ON: The timer is currently ON and will follow the programmed schedule.
- SLÖKKT: The timer is currently OFF and will follow the programmed schedule.
- Kveikt: The timer is forced ON, overriding any programs.
- SLÖKKT: The timer is forced OFF, overriding any programs.
4.4. Recall Function
The MYNDATEXTI button (often marked 'R' or 'RESET') is used to clear specific program settings or to reset the timer. A small pinhole button (R) is typically used for a full reset, which clears all programs and resets the time.
5. Viðhald
5.1. Umhirða rafhlöðu
The TM618 features a built-in rechargeable battery. To ensure its longevity and proper function, keep the timer connected to power for regular charging. If the timer is stored for extended periods without power, the battery may discharge, requiring a full charge upon reconnection.
5.2. Þrif
Clean the exterior of the timer module with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the plastic casing or display. Ensure no liquids enter the device.
6. Bilanagreining
- Skjárinn er auður: Check power connections. Ensure the unit has been powered for at least 30 minutes to charge the internal battery.
- Programs not executing: Verify that the current time is set correctly. Check that the timer is in "AUTO ON" or "AUTO OFF" mode, not forced ON/OFF. Review your programmed ON/OFF times for accuracy.
- Timer not responding to buttons: Perform a full reset using the small 'R' pinhole button. If issues persist, ensure proper power supply.
7. Tæknilýsing
| Eiginleiki | Gildi |
|---|---|
| Vörumerki | Sinotimer |
| Gerðarnúmer | TM618N-2 (Item model number: WN-5KCF-8SVQ) |
| Inntak Voltage | 200-250VAC |
| Úttaksgeta | 16 AMP / 250VAC, 20 AMP @30 VDC |
| Fjöldi forrita | 16 KVEIKJA/SLÖKKA forrit |
| Tímabil | 1 minute to 168 hours (7 days) |
| Innri rafhlaða | 40mAh endurhlaðanlegt |
| Efni | Plast |
| Litur | Hvítur |
| Vörumál | 25 x 18 x 8 cm; 11 g |
7.1. Mál

Figure 7.1: Front Dimensions.

Figure 7.2: Side Dimensions.
8. Ábyrgð og stuðningur
For information regarding product warranty, technical support, or service, please refer to the documentation provided with your purchase or contact your retailer. Keep your proof of purchase for any warranty claims.