ApooDr ASF16-18H2B

Notendahandbók fyrir ApooDr 18000 BTU Mini Split loftkælingu án loftstokka, inverterkerfis

Model: ASF16-18H2B | Brand: ApooDr

1. Kynning og vöruyfirlitview

The ApooDr 18000 BTU Mini Split Air Conditioner with Heat Pump is an advanced, energy-efficient system designed to provide optimal climate control for your space. Featuring inverter technology, it offers both powerful cooling and effective heating, suitable for areas up to 1000 sq ft. This system operates quietly and includes a comprehensive installation kit for convenience. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

ApooDr 18000 BTU Mini Split Air Conditioner with indoor unit, outdoor unit, and remote control.

Figure 1.1: Complete ApooDr Mini Split Air Conditioner System with indoor unit, outdoor unit, remote, and installation accessories.

2. Innihald pakka

Upon unpacking, please verify that all components listed below are present and in good condition. If any items are missing or damaged, contact customer support immediately.

  • Inni eining
  • Úti eining
  • Backlit LCD Remote Control
  • Pre-flared, Insulated Copper Line Set (approx. 16 FT)
  • Samskiptavír
  • Installation Accessories (e.g., drain hose, wall sleeve)
Image showing the indoor unit, outdoor unit, communication wires, pre-flared insulated copper line set, and remote control included in the package.

Figure 2.1: Visual representation of the main components included in your order.

3. Uppsetning og uppsetning

Fagleg uppsetning er nauðsynleg for this mini split system to ensure proper function, safety, and warranty validity. Incorrect installation can lead to system malfunction, property damage, or personal injury.

3.1 Gátlisti fyrir uppsetningu

  • Ensure the installation area meets local building codes and regulations.
  • Verify electrical supply (220V/60Hz) is compatible and sufficient.
  • Confirm proper drainage for condensate.
  • Ensure adequate clearance around both indoor and outdoor units for airflow and maintenance.

3.2 Uppsetningarskref (yfirview)

While professional installation is mandatory, a general overview ferlisins felur í sér:

  1. Mounting the indoor unit on the wall.
  2. Installing the outdoor unit on a stable, level surface.
  3. Connecting the pre-flared copper line set between the indoor and outdoor units.
  4. Connecting electrical wiring and communication cables.
  5. Vacuuming the refrigerant lines to remove air and moisture.
  6. Checking for leaks and performing a test run.

Fyrir ítarlegar leiðbeiningar skref fyrir skref um uppsetningu, vinsamlegast vísið til opinberu Uppsetningarhandbók (PDF).

A person giving a thumbs up next to an installed indoor mini split unit and an outdoor unit, indicating successful installation.

Mynd 3.1: Dæmiample of a professionally installed ApooDr Mini Split System.

4. Rekstraraðferðir

The ApooDr Mini Split system offers five distinct operating modes to ensure your comfort in various conditions. All modes are easily accessible and controllable via the included backlit LCD remote.

4.1 Available Modes

  • Sjálfvirkur háttur: The system automatically selects the appropriate operating mode (Cool, Heat, or Fan) based on the set temperature and current room temperature.
  • Flott stilling: Provides cooling to lower the room temperature. Adjustable from 62℉ (16.7℃) to 90℉ (32.2℃).
  • Dry Mode (Dehumidification): Minnkar rakastig í herberginu án þess að hitabreyting verði veruleg.
  • Hitastilling: Provides heating to raise the room temperature. Adjustable from 32℉ (0℃) to 86℉ (30℃).
  • Aðdáandi háttur: Hringrásar lofti án þess að hita eða kæla. Hægt er að stilla viftuhraða.

4.2 Aðgerðir fjarstýringar

The backlit LCD remote allows you to:

  • Kveiktu/slökktu á tækinu.
  • Select operating modes.
  • Stilltu hitastillingar.
  • Control fan speed.
  • Set timer functions (Timer ON/OFF).
  • Activate Sleep mode for quiet operation and energy saving.
  • Control oscillation (swing) of the air deflector.
  • Access special features like Turbo, Clean, LED display control, and Follow Me function.
Image showing the indoor unit with air flowing out, indicating both cooling and heating capabilities, and listing the five operating modes: Auto, Cool, Dry, Heat, and Fan.

Figure 4.1: The ApooDr Mini Split system offers 5 versatile operating modes for year-round comfort.

Close-up image of the backlit LCD remote control for the ApooDr Mini Split Air Conditioner, showing various function buttons and the digital display.

Figure 4.2: The intuitive backlit LCD remote control for easy system management.

5. Viðhald

Regular maintenance ensures the longevity and efficient operation of your ApooDr Mini Split system. Always turn off the power to the unit before performing any maintenance.

5.1 Þrif á loftsíu

The indoor unit is equipped with a permanently washable and easy-to-clean air filter. Regular cleaning of the air filter is crucial for maintaining air quality and system efficiency.

  • Tíðni: Clean the filter every two weeks or more frequently depending on usage and air quality.
  • Skref:
    1. Opnaðu framhlið innieiningarinnar.
    2. Gently remove the air filter(s).
    3. Þvoið síuna/síurnar með volgu vatni og mildu þvottaefni.
    4. Rinse thoroughly and allow to air dry completely before re-installing. Do not expose to direct sunlight.
    5. Re-install the dry filter(s) and close the front panel.

5.2 Viðhald útieiningar

Periodically inspect the outdoor unit for any obstructions (leaves, debris) around the condenser coils and fan. Gently clear any blockages to ensure proper airflow. Professional cleaning of the outdoor coil may be required annually.

6. Bilanagreining

If you encounter issues with your ApooDr Mini Split system, please refer to the official Leiðbeiningar um bilanagreiningu (PDF) fyrir ítarlegar lausnir. Hér að neðan eru nokkur algeng vandamál og almenn ráð:

6.1 Algeng vandamál og lausnir

  • Tækið kveikir ekki á sér: Athugið aflgjafann, rofann og gætið þess að rafhlöður fjarstýringarinnar séu ekki tæmdar.
  • Ónóg kæling/hitun: Verify correct mode selection and temperature setting. Clean air filters. Ensure no obstructions to airflow. Check for ice on the outdoor unit (in heating mode, during defrost cycle).
  • Óvenjuleg hljóð: Minor noises during operation are normal. Excessive or unusual noises may indicate a problem; consult the troubleshooting guide or a professional.
  • Vatnsleki frá innanhússeiningunni: Check the condensate drain line for blockages or improper slope.

If problems persist after consulting the troubleshooting guide, contact a qualified HVAC technician or ApooDr customer support.

7. Tæknilýsing

Key technical specifications for the ApooDr 18000 BTU Mini Split Air Conditioner (Model: ASF16-18H2B):

EiginleikiForskrift
Kælingargeta18000 BTU
Upphitunargeta18000 BTU
SEER2 (árstíðarbundið orkunýtnihlutfall 2)18.3
HSPF2 (Heating Seasonal Performance Factor 2)8.70
Voltage208/230V / 60Hz
UmfangssvæðiAllt að 1000 fm
Hávaðastig (innandyra)30 dB
KælivökvategundPre-Charged R-410A
Indoor Working Temperature (Cooling)62℉ ~ 90℉ (16.7℃ ~ 32.2℃)
Indoor Working Temperature (Heating)32℉ ~ 86℉ (0℃ ~ 30℃)
Outdoor Working Temperature (Cooling)5℉ ~ 122℉ (-15℃ ~ 50℃)
Outdoor Working Temperature (Heating)5℉ ~ 86℉ (-15℃ ~ 30℃)
VottanirAHRI Certified & UL Certified

8. Ábyrgð og stuðningur

8.1 Vöruábyrgð

The ApooDr Mini Split Air Conditioner comes with the following warranty coverage:

  • Þjappa: 5 ára ábyrgð
  • Hlutar: 2 ára ábyrgð

Please retain your proof of purchase for warranty claims. The warranty is valid only with professional installation.

8.2 Þjónustuver

For any questions, technical assistance, or warranty claims, please contact ApooDr customer support. Refer to the contact information provided with your product packaging or visit the official ApooDr websíðu til að fá upplýsingar um aðstoð.

Tengd skjöl - ASF16-18H2B

Preview Handbók um eiganda og uppsetningu ApooDr ASF16 serían af loftkælingu
Ítarleg handbók fyrir ApooDr ASF16 loftkælingar, sem nær yfir upplýsingar fyrir eigendur, uppsetningarferli, viðhald, bilanaleit og forskriftir. Lærðu hvernig á að setja upp og stjórna ApooDr loftkælingareiningunni þinni á öruggan hátt.
Preview Handbók og uppsetningarleiðbeiningar fyrir ApooDr loftkælingu af gerðinni Split-Type
Comprehensive guide for ApooDr split-type room air conditioners, covering safety precautions, unit specifications, features, care and maintenance, troubleshooting, accessories, and detailed installation procedures for both indoor and outdoor units. Includes refrigerant piping connection, air evacuation, electrical checks, and test run instructions.
Preview Leiðbeiningarhandbók fyrir ApooDr loftkælingu með split gerð
Þessi leiðbeiningarhandbók veitir nauðsynlegar upplýsingar og ráðleggingar um rétta uppsetningu, notkun og viðhald ApooDr Split Type loftkælingar til að tryggja bestu mögulegu afköst og endingu.
Preview Takmörkuð ábyrgðaryfirlýsing fyrir ApooDr hitunardælu með loftstokki og splitkerfi
Opinber takmörkuð ábyrgðaryfirlýsing fyrir ApooDr hitaldælukerfi með loftstokkum, þar sem nánar er útskýrt hvað felst í þjónustu, takmörkunum og skráningarkröfum vörunnar.
Preview Leiðbeiningar um stærðir ApooDr AHU3G-24HFN-AB loftkælingar
Ítarlegar víddarupplýsingar í tommum fyrir ApooDr AHU3G-24HFN-AB loftræstikerfi, þar á meðal inni- og útiíhluti. Á við um gerðirnar AHU3G-24HFN-AB-50FT, AHU3G-24HFN-AB-25FT og CAC-24k.
Preview Viðhaldshandbók fyrir ApooDr loftmeðhöndlunarbúnað af gerðinni 3D Inverter Series AHU 3. kynslóð
Þjónustuhandbók fyrir ApooDr AHU 3. kynslóð 3D Inverter serían af loftmeðhöndlunareiningum, sem fjallar um uppsetningu, notkun, bilanaleit og öryggisráðstafanir fyrir gerðir AHU3G-24HFN-A til AHU3G-60HFN-A.