1. Inngangur
This manual provides essential information for the proper installation, operation, and maintenance of your Atomic Compatible Furnace Filters. These filters are designed to provide efficient air filtration for your HVAC system, improving indoor air quality by capturing airborne particles.
Key features of your Atomic Compatible Furnace Filters include:
- MERV 8 filtration efficiency.
- Nominal Size: 20x25x5 inches (Actual Size: 24 3/4" X 19 3/4" X 4 7/8").
- Compatibility with Skuttle Air Cleaner Model DB-25-20 and Skuttle Part # 000-448-002 and 000-0448-006 448-2.
- Framleitt í Bandaríkjunum.
2. Uppsetning og uppsetning
Proper installation is crucial for the effective performance of your furnace filter. Always ensure your HVAC system is turned off before attempting to replace the filter.
2.1 Identifying the Correct Filter Size
Your Atomic Compatible Furnace Filters have a nominal size of 20x25x5 inches. The actual dimensions are slightly smaller to ensure a proper fit within the filter slot. The actual size is 24 3/4 inches in length, 19 3/4 inches in width, and 4 7/8 inches in thickness.
2.2 Uppsetningarskref
- Locate the Filter Slot: The filter slot is typically found in the return air duct of your furnace or air handler.
- Turn Off HVAC System: For safety, turn off the power to your furnace or air handler at the thermostat or circuit breaker.
- Fjarlægja gamla síu: Open the filter access door or panel. Note the direction of the airflow arrow on the old filter. Carefully slide out the old filter.
- Setja inn nýja síu: Orient the new Atomic filter so that the airflow arrow on its frame points in the same direction as the airflow in your ductwork (typically towards the furnace/air handler). Slide the new filter into the slot until it is fully seated.
- Öruggur aðgangur: Lokaðu og tryggðu aðgangshurð eða spjald síunnar.
- Endurheimta kraft: Kveiktu aftur á rafmagninu á hitunar-, loftræsti- og kælikerfinu þínu.

Image: Two Atomic Compatible Furnace Filters, illustrating their construction and the 'AIR FLOW' directional arrows on the side panels. The filters feature a pleated media design within a robust cardboard frame.
3. Rekstur
Once installed, your Atomic Compatible Furnace Filter operates passively as air passes through your HVAC system. The filter's MERV 8 pleated media effectively captures dust, pollen, pet dander, and other airborne particles, contributing to cleaner indoor air. No active user intervention is required during normal operation.
4. Viðhald
Regular maintenance, primarily filter replacement, is essential to maintain optimal HVAC system performance and indoor air quality.
4.1 Áætlun um síuskipti
The frequency of filter replacement depends on several factors, including:
- Umráð: More people in the home can lead to more airborne particles.
- Gæludýr: Homes with pets typically require more frequent filter changes due to pet dander.
- Allergies/Asthma: Individuals with respiratory sensitivities may benefit from more frequent changes.
- Local Environment: Areas with high pollen counts, construction, or pollution may necessitate more frequent changes.
As a general guideline, inspect your filter monthly and replace it every 30 to 90 days. During peak heating or cooling seasons, or if you have pets or allergies, more frequent replacement (e.g., every 30-60 days) may be necessary.
4.2 Skoðun
To inspect the filter, turn off your HVAC system and remove the filter as described in the installation steps. Hold the filter up to a light source. If you cannot see light through the filter media, it is likely clogged and should be replaced. A clean filter will allow light to pass through easily.

Image: A stack of five Atomic Compatible Furnace Filters, showcasing the depth and density of the pleated filter media, which is designed to maximize surface area for particle capture.
5. Bilanagreining
Most issues related to furnace filters can be resolved by ensuring proper installation and timely replacement.
5.1 Reduced Airflow
- Einkenni: Weak airflow from vents, HVAC system running constantly without reaching desired temperature.
- Hugsanleg orsök: Stífluð eða óhrein sía.
- Lausn: Inspect the filter. If it appears dirty or light cannot pass through, replace it with a new Atomic Compatible Furnace Filter.
5.2 Excessive Dust Accumulation
- Einkenni: Noticeable increase in dust on surfaces, despite regular cleaning.
- Hugsanleg orsök: Filter not installed correctly, allowing air to bypass it, or filter needs replacement.
- Lausn: Ensure the filter is fully seated in the slot and the airflow arrow is pointing in the correct direction. If the filter is old, replace it.
6. Tæknilýsing
| Eiginleiki | Gildi |
|---|---|
| Vörumerki | Atómkerfi |
| Upplýsingar um líkan | 448-2 |
| Nominal Product Dimensions | 20x25x5 tommur |
| Actual Product Dimensions | 24.75" L x 19.75" B x 4.88" Þ |
| MERV einkunn | 8 |
| Samhæf tæki | Air Cleaner, Air Conditioner, Furnace, HVAC, Heat Pump |
| Fjöldi hluta | 2 (í pakka) |
| Framleiðandi | Atómkerfi |
| Hlutanúmer | DSK8.0520252P |
7. Upplýsingar um ábyrgð
For specific warranty details regarding your Atomic Compatible Furnace Filters, please refer to the product packaging or contact the seller directly. Warranty terms typically cover manufacturing defects.
8. Þjónustudeild
If you have any questions, concerns, or require assistance with your Atomic Compatible Furnace Filters, please contact the seller or manufacturer through the platform where the purchase was made. Provide your order details and a clear description of your inquiry for prompt assistance.