1. Inngangur
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.
2. Öryggisupplýsingar
Fylgið eftirfarandi öryggisráðstöfunum til að koma í veg fyrir skemmdir á vörunni og tryggja öryggi notanda:
- Aflgjafi: Use only the specified power supply for this device. Ensure the power source meets the voltage og núverandi kröfur.
- Umhverfi: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
- Loftræsting: Ensure adequate ventilation around the device to prevent overheating. Do not block ventilation openings.
- Uppsetning: Uppsetning skal framkvæmd af hæfu starfsfólki í samræmi við gildandi rafmagnsreglugerðir og reglugerðir á hverjum stað.
- Viðhald: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
- Kaplar: Use appropriate and certified cables for all connections.
3. Innihald pakka
Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.
- AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
- Fljótleg uppsetningarleiðbeiningar
- Mounting Kit (e.g., DIN rail clip, screws)
- Terminal Block Connectors (for power input)
4. Vöru lokiðview
The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.
4.1 Skipulag framhliðar

Mynd 1: Framan view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Mynd 2: Nákvæm framhlið view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.
4.2 Components Description
- Ethernet tengi (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- Ethernet tengi (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- 10G tengi (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
- Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
- Stjórnborðshöfn: RJ45 port for local management and configuration via a serial connection.
- Endurstilla hnappur: Notað til að endurstilla tækið í verksmiðjustillingar eða endurræsa það.
- LED Vísar:
- SYS: Stöðuvísir kerfis.
- P1, P2: Power input status indicators.
- ALM: Viðvörunarvísir.
- RM, RC: Redundancy Management / Redundancy Control indicators.
5. Uppsetning
5.1 Uppsetning
The AXIS D8208-R is designed for DIN rail mounting.
- Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
- Hook the top edge of the DIN rail clip onto the DIN rail.
- Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
- Ensure the switch is securely fastened to the DIN rail.
5.2 Rafmagnstenging
The switch supports redundant power inputs (P1 and P2) for increased reliability.
- Ensure the power source is turned off before making any connections.
- Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
- Insert the terminal block connector into the P1 power input port on the switch.
- (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
- Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.
5.3 Nettenging
Connect network devices and uplink connections.
- Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
- Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.
5.4 Upphafleg stilling
Hægt er að stilla rofann með web-byggt viðmót eða skipanalínuviðmót (CLI) í gegnum stjórnborðsgáttina.
- Web Tengi: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
- Stjórnborðshöfn: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.
6. Rekstur
6.1 LED Vísar
Monitor the LED indicators for the operational status of the switch.
| LED | Staða | Lýsing |
|---|---|---|
| SYS | Grænt (solid) | Kerfið virkar eðlilega. |
| SYS | Grænt (blikkandi) | System is booting or performing an operation. |
| P1 / P2 | Grænt (solid) | Corresponding power input is active. |
| ALM | Red (Solid/Flashing) | An alarm condition exists (e.g., power failure, port error). Check system logs. |
| Port LED | Grænt (solid) | Tengi komið á. |
| Port LED | Grænt (blikkandi) | Gagnavirkni. |
6.2 Stjórnun og stillingar
The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.
- Web-undirstaða GUI: Aðgangur að rofanum web viðmót í gegnum staðlað web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
- CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
- SNMP: Rofinn styður SNMP fyrir samþættingu við netstjórnunarkerfi.
7. Viðhald
7.1 Þrif
To maintain optimal performance, periodically clean the exterior of the switch.
- Gakktu úr skugga um að rafmagnið sé aftengt áður en þú þrífur.
- Notið mjúkan, þurran klút til að þurrka ytri yfirborðin.
- Ekki nota fljótandi hreinsiefni eða úðabrúsa, þar sem þau geta skemmt tækið.
- Haldið loftræstiopum lausum við ryk og rusl.
7.2 vélbúnaðaruppfærslur
Athugaðu reglulega Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.
- Sækja viðeigandi vélbúnaðar file from the official Axis Communications support page for your model.
- Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web viðmót.
8. Bilanagreining
If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.
- Enginn kraftur:
- Check power cable connections to the switch and the power source.
- Verify the power supply is functioning correctly and providing the correct voltage.
- Ensure the P1/P2 LEDs are illuminated.
- Engin nettenging:
- Check Ethernet cable connections for both the switch and the connected device.
- Verify the link/activity LEDs on the respective port are active.
- Ensure the connected device is powered on and configured correctly.
- Check switch configuration (VLANs, port status) via the web tengi eða CLI.
- PoE tækið kveikir ekki á sér:
- Ensure the connected device is PoE compatible and within the switch's PoE budget.
- Check the PoE status for the port in the switch's management interface.
- Verify the Ethernet cable is a standard Cat5e/6 or higher.
- Aðgangur Web Interface Fails:
- Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
- Try accessing the switch via the console port to verify its IP configuration.
- Hreinsaðu skyndiminnið í vafranum þínum eða prófaðu annan vafra.
- Endurstilla verksmiðju: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Warning: This will erase all custom configurations.
9. Tæknilýsing
| Eiginleiki | Smáatriði |
|---|---|
| Vörumerki | Axis fjarskipti |
| Gerðarnúmer | 02621-001 |
| Vöruheiti | AXIS D8208-R Industrial 8-Port Managed PoE++ Switch |
| Hafnir | 8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+ |
| Power Input | Redundant DC power input (terminal blocks) |
| Þyngd hlutar | 3.37 pund (u.þ.b. 1.53 kg) |
| Stærðir pakka | 1.97 x 0.79 x 0.79 tommur (u.þ.b. 5 x 2 x 2 cm) |
| Framleiðandi | AXIS - ACCESS CONTROL |
| Dagsetning fyrst í boði | 29. maí 2024 |
10. Ábyrgð og stuðningur
For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications websíða.
Websíða: www.axis.com
Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.