Anern ECO 4200W-24V-WiFi

Notendahandbók fyrir Anern 4200W Hybrid sólarorkubreyti

Model: ECO 4200W-24V-WiFi

Vörumerki: Anern

1. Inngangur

This manual provides essential information for the safe and efficient operation of your Anern 4200W Hybrid Solar Inverter. This device is designed to convert DC power from solar panels into AC power for household appliances, while also managing battery charging and grid interaction. Please read this manual thoroughly before installation and operation.

Anern 4200W Hybrid Solar Inverter with WiFi module

Figure 1.1: Anern 4200W Hybrid Solar Inverter with included WiFi module.

2. Öryggisupplýsingar

Mikilvægar öryggisráðstafanir:

  • The starting power of inductive loads must be at least three times the rated power. Excessive inrush current can damage the inverter.
  • Connect circuits correctly and install circuit breakers for each circuit.
  • Power-on Sequence: First, turn on the battery, then start the inverter, and finally turn on the circuit breakers for photovoltaic (PV), grid, and load.
  • Power-off Sequence: Turn off in the reverse order of power-on.

Innbyggðir verndareiginleikar

The inverter is equipped with multiple protection mechanisms to ensure safe operation:

  • Yfirstraumsvörn
  • Undirvoltage vernd
  • Skammhlaupsvörn
  • Ofhitunarvörn
  • Yfirálagsvörn
  • Vörn gegn fyllingu
  • Yfirvoltage vernd
  • Ofhleðsluvörn
Skýringarmynd sem sýnir marga verndareiginleika invertersins

Mynd 2.1: Yfirview af alhliða verndareiginleikum invertersins.

3. Vörueiginleikar

  • Hár orkuframleiðsla: 4.2kW hybrid solar inverter (3600W rated power) with 24V DC to 220V/230V AC conversion.
  • Advanced MPPT Solar Charger: Integrated 120A MPPT solar charge controller. Max PV Array Open Circuit Voltage: 500Vdc. PV Array MPPT Voltage Range: 90~450Vdc. Max PV Array Power: 6000W.
  • Orkusparnaðarhamur: Features a dual-circuit AC output function. The primary and secondary outputs are typically used under normal conditions. If there is no PV or grid input and battery voltage is too low, the primary circuit will shut down, and only the secondary output will remain active to conserve energy.
  • Fjareftirlit: Supports WIFI/GPRS remote monitoring, allowing access to data and control of the inverter at any time. A WIFI module is included in the package.
  • Margar hleðslustillingar: Three optional charging modes: Solar Only, Solar and Utility, Solar Priority.
  • Margar úttaksstillingar: Output modes include Solar Priority, Utility Priority, and SBU Mode. These modes meet various application requirements.
  • Dual AC Outputs: The inverter features dual AC outputs. The combined power of the primary and secondary outputs should not exceed 3.6 kW.
  • RGB LCD Display: High-resolution RGB LCD display, readable even in daylight, with RGB indicators for different operating modes.
  • Samhæfni rafhlöðu: Supports 24V lead-acid and lithium batteries, including GEL, AGM, FLD, LI, and SLD types. The inverter can operate without batteries. It can only be connected to PACE BMS, not BMS from other manufacturers. When using a lithium battery, select 'User-defined' battery type in program 05.
All-in-one diagram showing hybrid inverter, MPPT, AC charger, and inverter functions

Figure 3.1: The Anern Hybrid Solar Inverter combines multiple functions into one unit.

Diagram showing dual AC outputs and RGB LCD display

Figure 3.2: Dual AC outputs and the high-resolution RGB LCD display.

Diagram showing compatibility with various battery types: GEL, AGM, FLD, LI, SLD

Figure 3.3: The inverter supports a wide range of 24V battery types.

4. Tæknilýsing

EiginleikiGildi
Gerðarnúmer4.2KW avec WIFI
VörumerkiAnern
Hvaðtage3600 Watts (Rated)
Vörumál44 x 51 x 21 cm
Þyngd hlutar10 kíló
AflgjafiKnúið sólarorku
Mælt er með umsóknumHome, Off-grid
LiturAppelsínugult
Hámark PV Array Open Circuit Voltage500V DC
PV Array MPPT Voltage Svið90~450Vdc
Hámark PV Array Power6000W
Hámark Hleðslustraumur120A (MPPT)
Hámark AC hleðslustraumur100A

5. Uppsetning og uppsetning

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Refer to the wiring diagram below for connection details.

Raflagnamynd lokiðview

Detailed wiring diagram for the Anern Hybrid Solar Inverter showing PV, battery, AC input, and AC output connections

Figure 5.1: Comprehensive wiring diagram for the inverter system.

Leiðbeiningar um tengingar

  • PV inntak:
    • PV Power: 4200W
    • Hámark PV Open Circuit Voltage: 500VDC
    • MPPT binditagSvið: 90VDC-450VDC
    • Start-up Voltage (initial charge): 120VDC
    • Recommended Cable: 10 AWG / 6mm²
    • It is recommended to connect solar modules in series.
  • Rafhlöðutenging:
    • Battery Type: 24V Lead-Acid / Lithium Battery
    • Recommended Cable and Terminal Size: 2 AWG / 25mm²
    • Mælt með öryggi: 150A
  • AC inntak (net/rafall):
    • AC Input: 230VDC
    • Hámarks AC Input Voltage: 300VAC
    • Max. AC Charging Current: 120A
    • Recommended Cable: 10 AWG / 6mm²
    • Recommended Breaker: 63A
  • AC úttak (álag):
    • Rekstrarafl: 4200W
    • AC Output Voltage: 220V / 230V
    • Recommended Cable: 10 AWG / 6mm²
    • Recommended Breaker: 63A
    • NOTE: The inverter's output is 230V. You can add a converter (not included) for 110V devices.

Ensure all connections are secure and follow local electrical codes. It is highly recommended to have installation performed by a qualified electrician.

6. Rekstraraðferðir

The Anern Hybrid Solar Inverter offers flexible operating modes to suit various energy management needs.

Charging Modes (3 Options)

Diagram illustrating the three charging modes and four output modes

Mynd 6.1: Yfirview of charging and output modes.

  • Solar Only (CSO): Solar energy is the primary source for charging the battery. The utility grid charges the battery only when solar energy is unavailable.
  • Solar and Utility (SNU): Solar energy and the utility grid charge the battery simultaneously.
  • Solar Priority (OSO): Solar energy is the sole charging source, regardless of its availability.

Output Modes (4 Options)

  • USB - Utility First: Loads are primarily powered by the utility grid. Solar and battery power are only used if the utility company cannot supply power.
  • SUB - Solar First (Standard): If solar energy is insufficient to power all connected loads, the grid supplies the loads simultaneously. The battery powers the loads only in two cases: if solar power is insufficient and grid power is unavailable, or if the grid is unavailable.
  • SUB - Priority: If solar energy is insufficient to power all connected loads, the battery powers the loads simultaneously. The utility company then supplies the loads with power when the battery voltage drops below the warning value for low values or in program 12.
  • MKS - Priority: Solar power has priority over loads. If solar power is insufficient, the loads are simultaneously supplied by the grid. The batteries serve as backup power.

RGB Operating Modes

The RGB display automatically changes color based on the inverter's operating status:

Diagram showing RGB operating modes: Stationary (White), PV (Violet), Battery (Red), Utility (Blue)

Figure 6.2: RGB display colors indicating different operating modes.

  • Kyrrstöðustilling: Hvítt ljós
  • PV ham: Fjólublátt ljós
  • Rafhlöðustilling: Rautt ljós
  • Notastilling: Blá ljós

Fjareftirlit

The included WiFi module enables remote monitoring of your inverter. This allows you to retrieve desired data and operate the inverter from a distance using a compatible application.

Image showing WiFi monitoring capability and various protection features

Figure 6.3: WiFi monitoring allows control and data access via mobile devices.

7. Viðhald

To ensure the longevity and optimal performance of your Anern Hybrid Solar Inverter, regular maintenance is recommended.

  • Regluleg þrif: Haldið ytra byrði invertersins hreinu og lausu við ryk og rusl. Gætið þess að loftræstiop séu ekki stífluð.
  • Tengingarathuganir: Periodically inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
  • Umhverfisskilyrði: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and extreme temperatures.
  • Uppfærsla vélbúnaðar: Athugaðu framleiðanda webvefsíðu eða app til að sjá allar tiltækar uppfærslur á vélbúnaði til að tryggja að inverterinn þinn hafi nýjustu eiginleika og villuleiðréttingar.

8. Bilanagreining

Ef þú lendir í vandræðum með inverterinn þinn skaltu íhuga eftirfarandi almennu skref til að leysa úr vandamálum:

  • Engin slökkvun/skjár slökktur: Check all power connections, including battery, PV, and AC input. Ensure circuit breakers are in the ON position. Verify battery voltage er innan rekstrarsviðs.
  • Engin úttaksafl: Check the load connections and ensure the inverter is not in an error state (indicated by the display or fault indicator). Verify that the output mode is correctly configured.
  • Lágt úttaksafl: Ensure PV input is sufficient and batteries are adequately charged. Check for any overload conditions.
  • Ofhleðsluviðvörun: Reduce the connected load. Ensure the starting power of inductive loads does not exceed the inverter's capacity.
  • Ofhitnun: Ensure proper ventilation around the inverter. Clear any obstructions from cooling fans.
  • Vandamál með WiFi tengingu: Ensure the WiFi module is correctly installed and within range of your network. Refer to the WiFi module's specific instructions for setup.

For persistent issues, refer to the detailed troubleshooting section in the complete user manual (if available in PDF format) or contact customer support.

9. Ábyrgð og stuðningur

Anern provides a 1-year warranty for this inverter. For any issues during use, please contact Anern customer support. You may be required to provide a video demonstrating the fault to assist technicians in diagnosing the cause.

For further assistance, please visit the official Anern store on Amazon or contact their customer service directly. Ensure you have your product model and purchase details ready when contacting support.

Visit the Anern Store on Amazon

Tengd skjöl - ECO 4200W-24V-WiFi

Preview ANERN FGI-S12000 Hybrid Solar Inverter User Manual
User manual for the ANERN FGI-S12000 Hybrid Solar Inverter. This guide details the installation, operation, safety, and specifications of the 12KW solar energy storage system, featuring MPPT charge control and UPS functionality.
Preview Anern MPPT Solar Inverter Product Manual: AN-FGI-AS12000 & AN-FGI-AS12000P
Comprehensive product manual for Anern AN-FGI-AS12000 and AN-FGI-AS12000P MPPT solar inverters. Covers installation, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.
Preview Anern AN-FGI-AS7200/AS7200P MPPT Solar Inverter Product Manual | Installation & Operation Guide
Comprehensive product manual for Anern AN-FGI-AS7200 and AN-FGI-AS7200P MPPT Solar Inverters. Learn about installation, operation, features, safety, and technical specifications for hybrid solar energy systems.
Preview Notendahandbók fyrir 2.0KVA/3.2KVA inverter MPPT SCC AC hleðslutæki
Ítarleg notendahandbók fyrir 2.0KVA/3.2KVA inverterinn með MPPT SCC og AC hleðslutæki. Fjallar um uppsetningu, notkun, eiginleika, forskriftir og bilanaleit. Inniheldur öryggisleiðbeiningar, kerfisarkitektúr og ítarlegar stillingar fyrir bestu mögulegu afköst.
Preview Anern FGI-S4000 MPPT Solar Inverter User Manual
User manual for the Anern FGI-S4000 MPPT Solar Inverter, detailing installation, operation, safety, and troubleshooting for solar energy storage systems.
Preview Notendahandbók fyrir MPPT Hybrid sólarorkubreyti
Þessi notendahandbók veitir ítarlegar upplýsingar um eiginleika, uppsetningu, notkun og viðhald MPPT Hybrid sólarorkubreytisins. Hún fjallar um tæknilegar upplýsingar, bilanaleit og öryggisráðstafanir fyrir AN-MPSG gerðina.