UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope Instruction Manual

Model: UPO1102

1. Inngangur

This instruction manual provides essential information for the safe and effective use of the UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope. The UPO1102 is a versatile instrument designed for electronic and electrical measurements, featuring a 100MHz bandwidth, 1 GSa/s real-time sample rate, 56 Mpts memory depth, and a 7-inch display. It incorporates Ultra Phosphor technology for enhanced waveform display and analysis capabilities.

Vinsamlegast lesið þessa handbók vandlega áður en tækið er notað til að tryggja rétta virkni og koma í veg fyrir skemmdir.

2. Öryggisupplýsingar

Always observe the following safety precautions to avoid personal injury and prevent damage to the instrument or other connected devices.

3. Vöru lokiðview

3.1 Framhlið

Framan view of the UNI-T UPO1102 Digital Oscilloscope, showing the 7-inch display, control knobs, and input connectors.

Figure 3.1: Front Panel of UPO1102 Oscilloscope

The front panel features the main display, various control knobs and buttons for waveform adjustment, trigger settings, and menu navigation. Input channels CH1 and CH2 are located at the bottom right.

3.2 Bakhlið

Aftan view of the UNI-T UPO1102 Digital Oscilloscope, showing the power input, USB ports, and ventilation.

Figure 3.2: Rear Panel of UPO1102 Oscilloscope

The rear panel includes the AC power input, USB ports for data transfer and printing, and ventilation grilles to ensure proper cooling during operation.

3.3 Mál

Dimensions of the UNI-T UPO1102 Digital Oscilloscope, showing a width of 13.23 inches, height of 6.46 inches, and depth of 4.13 inches.

Figure 3.3: UPO1102 Oscilloscope Dimensions

The physical dimensions of the UPO1102 are approximately 13.23 inches (width) x 6.46 inches (height) x 4.13 inches (depth).

4. Uppsetning

4.1 Upptaka og skoðun

Upon receiving your UPO1102 oscilloscope, carefully unpack all components and inspect them for any signs of damage. Retain the packaging for future transport or storage.

Venjulegur aukabúnaður:

4.2 Rafmagnstenging

  1. Gakktu úr skugga um að sveiflusjárinn sé staðsettur á stöðugu, sléttu yfirborði með fullnægjandi loftræstingu.
  2. Tengdu meðfylgjandi rafmagnssnúruna við riðstraumsinntakið á bakhlið sveiflusjásins.
  3. Stingdu hinum enda rafmagnssnúrunnar í jarðtengda riðstraumsinnstungu.
  4. Press the power button on the front panel to turn on the oscilloscope.

4.3 Probe Connection and Compensation

Before taking measurements, it is crucial to compensate the probes to ensure accurate readings.

  1. Connect a probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Connect the probe tip to the "Probe Comp" terminal and the ground clip to the ground terminal next to it.
  3. Ýttu á Sjálfvirk button. The oscilloscope will automatically adjust the settings to display the compensation signal.
  4. Observe the square wave displayed on the screen. If the waveform is not a perfect square (over-compensated or under-compensated), adjust the trimmer on the probe body using a non-metallic tool until a flat-top square wave is achieved.
  5. Repeat for the second probe if using both channels.
Example of a square wave displayed on the oscilloscope screen during probe compensation.

Figure 4.1: Probe Compensation Waveform

A correctly compensated probe displays a clean square wave. Adjust the probe's trimmer if the waveform shows overshoot or undershoot.

5. Notkunarleiðbeiningar

5.1 Grunnstýringar

5.2 Waveform Acquisition and Display

The UPO1102 features a 7-inch display and Ultra Phosphor technology for clear waveform visualization, even with complex signals.

Oscilloscope display showing a complex waveform with varying intensity, demonstrating Ultra Phosphor technology.

Figure 5.1: Ultra Phosphor Display

Ultra Phosphor technology provides a gradient display, where brighter areas indicate more frequent occurrences of the waveform, helping to visualize signal anomalies and variations.

Oscilloscope display showing two overlaid waveforms, demonstrating multi-channel measurement.

Figure 5.2: Multi-Channel Waveform Display

The UPO1102 can display and analyze two channels simultaneously, allowing for comparison of different signals.

5.3 Mælingarföll

5.4 Digital Decoding

The innovative hardware decoding feature allows for real-time decoding of serial bus protocols. With a deep storage of 56 Mpts, decoding speed is maintained at millisecond levels, preventing delays when viewing decoded data. This function does not affect the waveform refresh rate, maintaining the digital fluorescence display effect.

Oscilloscope display showing decoded serial data alongside the raw waveform.

Figure 5.4: Digital Decoding Example

The decoding feature displays protocol information directly on the screen, simplifying debugging of serial communications.

5.5 Gagnageymsla og tenging

6. Viðhald

6.1 Almenn umönnun

6.2 Þrif

To clean the exterior of the oscilloscope:

  1. Disconnect the power cord and all probes/cables.
  2. Notaðu mjúkan klút dampened with mild detergent and water. Do not use abrasive cleaners or solvents.
  3. For the display, use a soft, lint-free cloth specifically designed for electronic screens.
  4. Ensure the instrument is completely dry before reconnecting power.

7. Bilanagreining

This section addresses common issues you might encounter with the UPO1102 oscilloscope. For problems not listed here, contact UNI-T customer support.

VandamálMöguleg orsökLausn
Engin skjár eftir að kveikt er á honum.Power cord not connected, power outlet faulty, instrument fault.Athugið tengingu rafmagnssnúrunnar. Prófið rafmagnsinnstunguna. Ef vandamálið heldur áfram, hafið samband við þjónustuver.
Engin bylgjuform birtistProbe not connected, signal too small/large, trigger not set correctly, channel off.Ensure probe is connected to signal source. Press Sjálfvirk button. Adjust vertical scale (Volts/Div) and horizontal scale (Sec/Div). Check trigger level. Ensure channel is enabled.
Óstöðug bylgjuform.Trigger level incorrect, trigger mode unsuitable, signal noise.Adjust trigger level. Try different trigger modes (e.g., Normal or Single). Reduce noise in the signal path.
Incorrect measurements.Probe compensation incorrect, probe attenuation setting wrong, measurement settings incorrect.Perform probe compensation (Section 4.3). Verify probe attenuation setting matches physical probe (e.g., 1X, 10X). Check measurement parameters.

8. Tæknilýsing

ParameterGildi
Bandbreidd100 MHz
Rásir2
Rauntíma Sample Verð1 GSa/s
Minni Dýpt56 mpts
Bylgjuformsupptökuhraði500,000 wfm/s
Skjár7 tommu
FFT Sampling Stig1 mpts
Vörumál13 x 4 x 6 tommur (u.þ.b. 330 x 102 x 152 mm)
Þyngd hlutar8.13 pund (u.þ.b. 3.69 kg)
FramleiðandiUNI-T
ASINB0D7F2D9MS
Dagsetning fyrst í boði19. júní 2024

9. Ábyrgð og stuðningur

For warranty information, technical support, or service inquiries regarding your UNI-T UPO1102 oscilloscope, please refer to the official UNI-T websíðuna eða hafðu samband við þjónustudeild þeirra.

UNI-T Official Store: Heimsæktu UNI-T verslunina á Amazon

Please have your product model (UPO1102) and ASIN (B0D7F2D9MS) available when contacting support.