Garvee WY-_ZTaGifLdJViUlxc2P5qjQNzir39P

Garvee 20K BTU Dual Zone Mini Split AC/Heating System

Model: WY-_ZTaGifLdJViUlxc2P5qjQNzir39P

Leiðbeiningarhandbók

1. Inngangur

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Garvee 20K BTU Dual Zone Mini Split AC/Heating System. Please read it thoroughly before installation and keep it for future reference.

Your Garvee Mini Split system offers high-efficiency heating and cooling with independent climate control for two zones. Key features include:

2. Öryggisupplýsingar

Fagleg uppsetning krafist: The air conditioner must be installed by professional personnel to ensure safety, optimal performance, and warranty coverage.

Meðhöndlun kælimiðils:

Rafmagnsöryggi:

3. Vöru lokiðview & Íhlutir

Your Garvee Mini Split system includes an outdoor condenser unit and two indoor air handler units. Below are images illustrating the main components and their dimensions.

Garvee Dual Zone Mini Split AC/Heating System main units

Figure 3.1: Garvee 20K BTU Dual Zone Mini Split AC/Heating System (Outdoor and Indoor Units)

Garvee Indoor Unit with front panel open showing filters

Figure 3.2: Indoor Unit with front panel open, revealing air filters.

Garvee Remote Control for Mini Split AC

Figure 3.3: Wireless Remote Control for adjusting settings.

Innifalið íhlutir:

Note: Copper tubing and power cord are not included and must be sourced separately.

4. Tæknilýsing

EiginleikiForskrift
VörumerkiGarvee
GerðarnúmerWY-_ZTaGifLdJViUlxc2P5qjQNzir39P
Getu20,000 BTU (9K+9K Dual Zone)
Kælikraftur20000 Breskar varmaeiningar
Árstíðabundið orkunýtnihlutfall (SEER2)20
Voltage208-230V
Hvaðtage1370.0
Hljóðstig42 desibel
Stærð vöru (útieining)36.5 cm B x 27.52 cm Þ x 14.96 cm H
Product Dimensions (Indoor Unit 9K BTU)31.93 cm B x 11.5 cm Þ x 7.99 cm H
Þyngd hlutar152.1 pund
Sérstakur eiginleikiSvefnstilling
UppsetningaraðferðSkipt kerfi

5. Uppsetning og uppsetning

Professional HVAC installation is required for this system. The following steps provide an overview of the installation process. Refer to the detailed service manual for complete instructions.

5.1 Innanhússuppsetning

  1. Athugun fyrir uppsetningu: Before starting, check the status of both indoor and outdoor units. Verify no parts are broken, the indoor cross-fan operates, and the remote controller functions. If the cross-fan does not operate, check and adjust it first.
  2. Athugun á gasflæði: Verify there is no gas flow from the connector. If gas is detected, check the evaporator for any leakage.
  3. Raflagnir: Unfix the electric box cover. Connect the indoor and outdoor unit connection wires. Double-check the marks on the wires (1, 2, 3, and ground) to ensure correct and reliable wiring.
  4. Piping Direction: Based on the installation location, decide the piping direction and cut the face frame case accordingly. Ensure the cut edges are clean and smooth to prevent damage to the pipes.
  5. Tengja rör: Adjust the connection pipes, paying attention to the alignment of the horn. Control the wrench's strength to prevent nut rupture. Ensure no gas leakage after pipe connection.
  6. Connect Drainage Pipe: Connect the drainage pipe. It must be sealed with electrical tape to ensure no water leakage.
  7. Wrap Pipes and Wires: Wrap the refrigerant pipes, drainage hose, and wiring together. Important: Retain the pipe connectors for later leak detection.
  8. Settu upp veggplötu: Install the wall plate, ensuring it is secure enough to hold the indoor unit.
  9. Festa innanhússeiningu: Pass the pipes through the wall hole. Fix the indoor unit firmly on the mounting plate.

Video 5.1: Detailed installation steps for the indoor unit, including wiring and pipe connections. (Source: GarveeTech)

5.2 Uppsetning utanhúss

  1. Lagfæra útieiningu: Fix the outdoor unit on the mounting bracket. It is recommended to use rubbers on the feet to decrease possible vibration and noise.
  2. Open Refrigerant Pipes Cover: Open the refrigerant pipes cover on the outdoor unit.
  3. Tengja kælimiðilsleiðslur: Connect the refrigerant pipes similar to the indoor unit. Control the force of the wrench to prevent nut breakage. Connect the pipe horn to the 2-way and 3-way valve straightly to prevent gas leakage.
  4. Rafmagnstengingar: Open the electrical control box. The indoor and outdoor connection cable goes to the left hole of the cover, and the power cord to the right hole. Connect the indoor and outdoor connection wires to the electric terminal, paying attention to the marks of 1, 2, 3, and ground on the wires. They must be one-to-one correspondence with the markings on the terminal. Connect the power supply cable to the electric terminal. Ensure all wires are connected correctly and reliably.

Video 5.2: Detailed installation steps for the outdoor unit, including wiring and pipe connections. (Source: GarveeTech)

5.3 Vacuuming and Leakage Detection

  1. Tengdu lofttæmisdælu: Connect one hose from the manifold low pressure gauge to the outdoor unit service port on the three-way valve. Then connect the manifold gauge to the vacuum pump.
  2. Tómarúmskerfi: Switch on the vacuum pump and open the gauge low pressure valve. For split AC, vacuum the unit for at least 15 minutes until the vacuum gauge is maintained at -14.5 psi. For R32 or R454B units, based on pipe length, vacuum for 15-30 minutes when pump capacity is 4-4.5 CFM.
  3. Pressure Hold Test: Close the low pressure valve on the manifold gauge, then switch off the vacuum pump. Hold the pressure for 5 minutes. Ensure the rebound of the compound gauge pointer does not exceed 0.73 psi. If it rebounds more than 0.73 psi, check and repair the leakage point, most likely from the pipe connector.
  4. Losun kælimiðils: Open the outdoor unit low pressure valve counterclockwise for 1/4 turn with a hexagonal wrench to let a little refrigerant fill the system. Close the low pressure valve after 5 seconds. Check all pipe connectors of indoor and outdoor units for gas leakage. If leakage is found, repair and tighten the connection.
  5. Þétti vegggat: Once no gas leakage is found, clean the connectors and wrap the indoor connector pipes. Seal the wall hole with sealing cement.
  6. Remove Pressure Hose: Keep the gauge at positive pressure and quickly remove the pressure hose from the outdoor unit service valve.
  7. Reinstall Protective Caps: Reinstall the protective caps of the service port, low pressure, and high pressure valves of the outdoor unit. Reinstall the valves cover.

Video 5.3: Vacuuming and leakage detection process for the mini split AC unit. (Source: GarveeTech)

6. Notkunarleiðbeiningar

After installation, switch on the unit for a running test. The system offers various modes for personalized comfort:

Wi-Fi og raddstýring: Each indoor unit has its own remote control, plus Wi-Fi and voice control (works with Alexa & Google Assistant). You can control the system from your smartphone, allowing you to set the temperature before you arrive home.

Garvee Mini Split AC with smartphone app control and voice assistant logos

Figure 6.1: Smart control features via smartphone app and voice assistants.

Video 6.2: Instructions on how to connect the Dual Zone Mini Split Air Conditioner to Wi-Fi. (Source: GarveeTech)

7. Viðhald

Regular maintenance ensures the longevity and efficiency of your Garvee Mini Split system. Teach users how to use and normally maintain the air conditioner.

8. Bilanagreining

If you encounter issues with your Garvee Mini Split system, consider the following general troubleshooting steps. For complex problems, contact a professional HVAC technician.

9. Ábyrgð og stuðningur

Your Garvee Mini Split AC/Heating System comes with a 30 daga ábyrgð framleiðanda. For warranty claims or technical support, please refer to the contact information provided with your purchase documentation.

Tengd skjöl - WY-_ZTaGifLdJViUlxc2P5qjQNzir39P

Preview 14,000 BTU Portable AC - Product Information
Official product information for the 14,000 BTU Portable Air Conditioner, model QCFDI, distributed by Garvee. Includes support contact details.
Preview Uppsetningarhandbók og varahlutalisti fyrir 12'x16' pergola | Garvee
Ítarleg leiðbeiningar um samsetningu Garvee 12'x16' Pergola, þar á meðal ítarlegur varahlutalisti, upplýsingar um vélbúnað og skref-fyrir-skref leiðbeiningar.
Preview Garvee Electric Fireplace QC7HM - User Manual, Installation, and Operation Guide
Comprehensive user manual and installation guide for the Garvee Electric Fireplace, model QC7HM. Includes safety information, setup instructions, operation details, and troubleshooting tips.
Preview Uppsetningar- og notkunarhandbók fyrir innfellda rafmagnsarinn frá Garvee
Þessi handbók veitir mikilvægar öryggisupplýsingar, uppsetningarleiðbeiningar, notkunarferla og viðhaldsleiðbeiningar fyrir innfellda rafmagnsarinninn Garvee af gerðunum ZHX-50-086, ZHX-60-088, ZHX-72-091, ZHX-88-315S og ZHX-88-316S. Lærðu hvernig á að setja upp, stjórna og annast rafmagnsarinninn þinn á öruggan hátt.
Preview GARVEE Snow Shovel 7APPA Assembly Instructions and User Guide
Detailed assembly instructions and safety information for the GARVEE Snow Shovel, model 7APPA. Learn how to assemble and safely use your snow shovel.
Preview Leiðbeiningar um samsetningu GARVEE rekki 7XEDP
Ítarlegar samsetningarleiðbeiningar fyrir GARVEE rekkann, vörunúmer 7XEDP, þar á meðal hlutalistar og leiðbeiningar skref fyrir skref fyrir tvær útgáfur.