Carnegie-Robotics -logo

Carnegie Robotics 55001384 Sjálfvirknistýringareining

Carnegie-Robotics-55001384-Autonomy-Controller-Module-product

Tæknilýsing

  • Framleiðandi: Carnegie Robotics
  • Gerðarnúmer: 55001384
  • Samþættingarleiðbeiningar: KDB 996369 D03 OEMManual v01

Lýsing

Qualcomm® Robotics RB5 Core Kit consisting of Thundercomm TurboX C865 System on Module with customization around 12GB Ram and external antennas enabled for system integration. See Qualcomm or Thundercomm hardware manuals for specifications to each product.

Leiðbeiningar um samþættingu fyrir framleiðendur hýsingarvara samkvæmt KDB 996369 D03 OEM handbók v01 (ISED viðurkennd)

Listi yfir gildandi FCC reglur

  1. CFR 47 FCC PART 15 SUBPART C&E has been investigated. It is applicable to the modular. Specifically, an assessment of the worst case operating conditions has to be performed by the module integrator and tested on the host product for compliance to FCC part 15.247 and part 15.407.

Sérstök notkunarskilyrði

  1. Þessi eining er sjálfstæð eining. Ef lokaafurðin mun fela í sér margfeldi samtímis sendingarskilyrði eða mismunandi rekstrarskilyrði fyrir sjálfstæðan einingasendi í hýsil, verður hýsilframleiðandinn að hafa samráð við einingarframleiðandann um uppsetningaraðferðina í lokakerfinu.
  2. Takmarkaðar verklagsreglur fyrir einingar. – Á ekki við.
  3. Hönnun rekjaloftneta. – Á ekki við.

Athugasemdir um útsetningu fyrir útvarpsbylgjum

  1. To maintain compliance with FCC’s and ISED’s RF Exposure guidelines, this equipment should be installed and operated at a minimum distance of 20cm from your body.

Loftnet

  1.  This radio transmitter FCC ID: 2AMDR-55001384 / IC: 24410-55001384 has been approved by the Federal Communications Commission to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device.
Innri

Auðkenning

Lýsing á loftneti Loftnetsgerð Hámarksávinningur loftnets
Loftnet 0** Wi-Fi loftnet Ytri loftnet 2X MIMO WIFI 2.4G Wi-Fi: 1.2 dBi,

5G Wi-Fi: 2.0dBi

Loftnet 1 Wi-Fi loftnet Ytri loftnet 2X MIMO WIFI 2.4G Wi-Fi: 1.2 dBi,

5G Wi-Fi: 2.0dBi

  • Bluetooth has been disabled on device and has not been tested

Antennas Tested

  • Abracon Part Number AECW0401W2-0600F_DS
  • Taoglas MA210.K.CG.001

Upplýsingar um merkingar og samræmi.

  1. The final end product must be labeled in a visible area with the following: Contains FCC ID: 2AMDR-55001384, IC: 24410-55001384

Upplýsingar um prófunaraðferðir og viðbótarprófunarkröfur

  1. The Host manufacturers are strongly recommended to confirm compliance with FCC and ISED requirements for the transmitter when the module is installed in the host.  Additional testing, Part 15 Subpart B and ICES-003 disclaimer The host manufacturer is responsible for compliance of the host system with module installed with all other applicable requirements for the system such as FCC Part 15 B and ICES-003.

FCC varúð

  • Allar breytingar eða breytingar sem ekki hafa verið samþykktar sérstaklega af þeim aðila sem ber ábyrgð á samræmi gæti ógilt heimild notanda til að nota búnaðinn.

FCC and ISED Statements

This device complies with Part 15 of the FCC Rules and with ICES-003 of the ISED rules. Operation is subject to the following two conditions:

  1. Þetta tæki má ekki valda skaðlegum truflunum, og
  2. þetta tæki verður að taka við öllum truflunum sem berast, þar með talið truflunum sem geta valdið óæskilegri notkun.

MIKILVÆG ATHUGIÐ:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of the ISED Canada rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Stilltu eða færðu móttökuloftnetið.
  • Auktu aðskilnað milli búnaðar og móttakara.
  • Tengdu búnaðinn í innstungu á annarri hringrás en þeirri sem móttakarinn er tengdur við.
  • Hafðu samband við söluaðilann eða reyndan útvarps-/sjónvarpstæknimann til að fá aðstoð.

Statements regarding human exposure

  • With respect to radiofrequency radiation exposure Information, it is declared that this equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment.
    • This equipment should be installed and operated at a minimum distance of 20 cm between the radiator and your body.
    • Þessi sendir má ekki vera staðsettur samhliða eða starfræktur í tengslum við önnur loftnet eða sendi.

Algengar spurningar

What are the recommended distances for RF exposure compliance?

The equipment should be installed and operated at a minimum distance of 20cm from the body to comply with FCC's and ISED's RF Exposure guidelines.

Can I use antennas not listed in the manual?

Antenna types not included in the approved list are strictly prohibited for use with this device to maintain compliance.