Apera Instruments Manuals & User Guides
Apera Instruments manufactures precision electrochemical sensors and meters for measuring pH, conductivity, ORP, dissolved oxygen, and turbidity in laboratory and industrial environments.
About Apera Instruments manuals on Manuals.plus
Apera hljóðfæri is a leading manufacturer of electrochemical sensors and scientific instruments, established in 1991. Dedicated to providing reliable and affordable testing solutions, the company produces a wide range of meters for measuring pH, oxidation-reduction potential (ORP), conductivity, TDS, salinity, dissolved oxygen, and turbidity. With over 30 years of industry experience, Apera Instruments operates R&D and manufacturing facilities certified to ISO 9001:2015 standards, ensuring strict quality control and continuous innovation.
The brand is well-known for its pocket-sized testers, such as the popular PH60 series, as well as portable and benchtop meters designed for agriculture, hydroponics, environmental monitoring, and food processing. Apera also integrates modern technology into its products, offering smart meters compatible with the ZenTest® mobile app for data management and analysis via Bluetooth. Headquartered in Columbus, Ohio for the US market and Wuppertal, Germany for Europe, Apera Instruments provides global support and expertise in water analysis.
Apera Instruments manuals
Nýjustu handbækur frá manuals+ valið fyrir þetta vörumerki.
Notendahandbók fyrir APERA 871 pH-rafskaut fyrir vatnslausa lausn
Notendahandbók fyrir snjall pH-mæli APERA PH60Z-MT
Notendahandbók fyrir snjall pH-mæli fyrir APERA PH60Z-PW hreint vatn
APERA PH60Z-VS snjall pH-mælir fyrir seigfljótandi sýruramples notendahandbók
Notendahandbók APERA PH60Z-HF Smart pH Meter
Notendahandbók APERA LabSen 861 pH rafskaut fyrir flóknar og ætandi lausnir
Notendahandbók APERA LabSen 851-1 Seigfljótandi pH rafskaut rafefnafræðilegir skynjarar
APERA LebSen 853-H pH, hitarafskaut notendahandbók
APERA LabSen 833 pH rafskaut notendahandbók
Apera Instruments 1M LiCl in Ethanol Safety Data Sheet (SDS)
PH8500 Portable pH Meter User Manual - Apera Instruments
Apera Instruments TDS20 Value TDS Meter User Manual
Apera LabSen 845 pH/Temp. Electrode User Manual
Apera Instruments Water Hardness Calibration Solution B1, B2, B3 Safety Data Sheet (SDS)
Apera PH20 Value pH Tester Kit User Manual - Guide and Specifications
Notendahandbók fyrir flytjanlegan leiðnimæli EC850
Apera TN500 flytjanlegur gruggmælir: Leiðbeiningarhandbók og upplýsingar
Notendahandbók fyrir Apera PH20 pH mælibúnað
Notendahandbók fyrir Apera Instruments PH60 Premium pH-mæli
Notendahandbók fyrir Apera PH60 pH-mæli - Leiðbeiningar og upplýsingar
Öryggisblað fyrir APERA Instruments pH 4.00 stuðpúðalausn
Apera Instruments manuals from online retailers
Apera Instruments AI311 PH60 Waterproof pH Pocket Tester Kit User Manual
Leiðbeiningarhandbók fyrir Apera Instruments PC60-Z Bluetooth fjölbreytu snjallprófara
Notendahandbók fyrir Apera Instruments MP511 borðpH-mæli
Notendahandbók fyrir Apera Instruments 201DJ-C AI3115 tvítengingar pH rafskaut
Notendahandbók fyrir Apera Instruments GroStar Series GS3 EC/ppm pennaprófunarbúnað (AI103G)
Notendahandbók fyrir Apera Instruments GroStar Series GS2-E jarðvegsmæla pH-mæli (AI802G)
Notendahandbók fyrir Apera Instruments AI316 PC60 5-í-1 pH/EC/TDS/Saltu-/Hitamæli
Notendahandbók fyrir Apera Instruments LabSen 823 pH/hitastigs rafskaut
Notendahandbók fyrir flytjanlegan pH-mæli fyrir Apera Instruments SX811-SS
Leiðbeiningarhandbók fyrir Apera Instruments AI521 PH800 pH-mælibúnað fyrir rannsóknarstofu
Notendahandbók fyrir flytjanlegan pH-mælibúnað Apera Instruments PH850-MS
Notendahandbók fyrir Apera Instruments PH820 pH-mælibúnað fyrir borð
Apera Instruments video guides
Horfðu á myndbönd um uppsetningu, uppsetningu og bilanaleit fyrir þetta vörumerki.
Apera Instruments support FAQ
Algengar spurningar um handbækur, skráningu og stuðning fyrir þetta vörumerki.
-
How often should I calibrate my Apera pH meter?
For high-accuracy measurements (≤ ±0.02 pH), calibrate the electrode before every test session. For general use (≥ ±0.1 pH), calibration every 1-2 weeks is usually sufficient. Calibration is also required if the electrode has not been used for a long time or after measuring strong acids/bases.
-
How should I store the pH electrode when not in use?
Add a few drops of 3M KCL soaking solution (SKU: AI1107) to the protective cap and close it tight. Never store the electrode in distilled, RO, or deionized water, as this will damage the sensor sensitivity.
-
What do I do if I see white crystals around the probe cap?
White crystals are normal and indicate the presence of the 3M KCL storage solution, which crystallizes over time. These are not poisonous; simply rinse them off with water before using the tester.
-
Why is my pH reading unstable or slow to stabilize?
Unstable readings often occur when measuring pure water (distilled/RO) due to low conductivity. Adding a specialized ionic strength adjuster or using a specialized electrode (like LabSen 803) helps. Also, ensure the glass bulb is clean and hydrated in 3M KCL solution.
-
How do I clean the electrode sensor?
For general contaminants, rinse with distilled water. for oil/fat deposits, use warm water with dish soap (soak for 5-10 mins). For protein buildup, use the Apera Electrode Cleaning Solution (AI1166). Always rehydrate in KCL solution for 12 hours after rigorous cleaning.