COMMCOPE-merki

COMMSCOPE CPP-UDDM-SL-1U-24 Unshielded Discrete Distribution Module

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-Product

Tæknilýsing

  • Efnisauðkenni: 760237040
  • Hlutanr.: CPP-UDDM-SL-1U-24
  • Lýsing: Unshielded Discrete Distribution Module Panel, SL, 1U, 24 port, Black

Almennt
The CommScope® Unshielded discrete distribution module (UDDM) panels are available in a 24 port or 48 port, flat, angled or recessed angled configuration.
The panel consists of a rack mounted base unit, rear cable management, labels for port numbering, hardware kit and hook and loop straps. Each panel mounts in a 19-inch (483mm) equipment rack with universal hole spacing. Ordering information is listed below:

Efni ID Hlutanr. Lýsing
760237040 CPP-UDDM-SL-1U-24 Unshielded Discrete Distribution Module Panel, SL, 1U, 24 port, Black
760237041 CPP-UDDM-SL-2U-48 Unshielded Discrete Distribution Module Panel, SL, 2U, 48 port, Black
760237042 CPPA-UDDM-SL-1U-24 Unshielded Angled Discrete Distribution Module Panel, SL, 1U, 24 port, Black
760237043 CPPA-UDDM-SL-2U-48 Unshielded Angled Discrete Distribution Module Panel, SL, 2U, 48 port, Black
760237044 CPPR-UDDM-SL-1U-24 Unshielded Recessed Angled Discrete Distribution Module Panel, SL, 1U, 24 port, Black
760237045 CPPR-UDDM-SL-2U-48 Unshielded Recessed Angled Discrete Distribution Module Panel, SL, 2U, 48 port, Black
760237052 CPP-UDDM-KJ-1U-24 Unshielded Discrete Distribution Module Panel, Keystone, 1U, 24 port, Black
760241547 CPP-UDDM-KJ-2U-48 Unshielded Discrete Distribution Module Panel, Keystone, 2U, 48 port, Black
760250319 CPPA-UDDM-KJ-1U-24-WH Unshielded Angled Discrete Distribution Module Panel, Keystone, 1U, 24 port, White
760250320 CPPA-UDDM-KJ-2U-48-WH Unshielded Angled Discrete Distribution Module Panel, Keystone, 2U, 48 port, White
760253047 CPPA-UDDM-KJ-1U-24 Unshielded Angled Discrete Distribution Module Panel, Keystone, 1U, 24 port, Black
760253048 CPPA-UDDM-KJ-2U-48 Unshielded Angled Discrete Distribution Module Panel, Keystone, 2U, 48 port, Black

Athugið: sample product images are shown below for reference.

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (1)Verkfæri sem krafist er

  • Phillips höfuðskrúfjárn.
  • Flat blade screwdriver, max 2.9mm dia.

Varahlutalisti

Staðfestu hluta gegn varahlutalistanum hér að neðan:

 

 

24-Port Flat Panel

 

 

48-Port Flat Panel

Magn

24-Port            48-Port Ang Panel Ang panel

 

 

24-Port R-Ang Panel

 

 

48-Höfn

R-Ang Panel

Lýsing
1 24-porta flatskjár
1 48-porta flatskjár
1 24-porta hornplata
1 48-porta hornplata
1 24-porta innfelld hornplata
1 48-porta innfelld hornplata
1 1 1 1 1 1 P12-24 x ½” mounting screw kit
1 2 1 2 1 2 Merkihaldarasett
1 2 1 2 1 2 Rear cable management
1 2 1 2 1 2 Hook-and-loop straps kit

VIÐVÖRUN – Mikilvægar öryggisleiðbeiningar

Þegar þessi vara er notuð skal fylgja eftirfarandi grundvallaröryggisráðstöfunum til að draga úr hættu á eldi, raflosti og meiðslum á fólki:

  1. Settu aldrei upp fjarskiptalagnir á blautum stöðum nema þau séu hönnuð fyrir blauta staði.
  2. Settu þessa vöru aldrei upp í eldingum. Það er lítil hætta á raflosti.
  3. Aldrei snerta óeinangruð samskiptaleiðslur eða tengi nema samskiptarásin hafi verið aftengd við netviðmótið.
  4. Varúð: Allar raflögn sem tengjast þessum búnaði verða að uppfylla viðeigandi staðbundna og landsbundna byggingarreglur og netlagnastaðla fyrir samskiptakapla.

Installation of Panel

Skref 1 - Festu spjaldið á rekki

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (2)

Step 2 – Assemble Rear Cable Management and Other Accessories
Attach rear cable management as shown and insert four hook-and-loop straps to the rear cable management.

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (3)

Step 3 – Populate Panel with Jacks (Jacks ordered separately)

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (4)24-Port Panel

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (5)

  1. Connect cables to jacks per instructions provided with the individual jacks.
  2. Populate panel with jacks and route cabling as shown.
    Athugið: Secure cables using the hook-and-loop straps provided.

Skref 4 - Festa upplýsingamerkiCOMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (6)

  1. Enter information on the white information labels provided in label holder kits. Snap holders into panel modules and insert labels into label holders as shown in the above image.
  2. To print a designation label
    1. Farðu til http://www.commscope.com/Resources/Labeling-Templates and scroll down to “Copper Panels” and select the proper label template.  Or go to https://www.commscope.com/ and search individual part number (material ID).
    2. Select the part number and scroll down to the “documentation and downloads” section. In the template section, select the required label size.

Athugið: Merking websíða hefur tvo möguleika til að prenta merkimiða; Letter stærð og A4 stærð.

COMMSCOPE-CPP-UDDM-SL-1U-24-Unshielded-Discrete-Distribution-Module-fig- (7)

  1. Insert a small, 2.9mm dia. max flat-blade screwdriver into the slot above the jack and rotate to release the latch.
  2. Remove jack from rear of panel.
  3. Athugið – rear cable management may need to be removed to enable access to the release slot on some jack positions.

Vörumerki
Öll vörumerki auðkennd með ® eða ™ eru skráð vörumerki eða vörumerki, í sömu röð, CommScope, Inc. Þetta skjal er eingöngu ætlað til skipulagningar og er ekki ætlað að breyta eða bæta við neinar forskriftir eða ábyrgðir sem tengjast CommScope vörum eða þjónustu. CommScope hefur skuldbundið sig til að uppfylla ströngustu staðla um viðskiptaheiðarleika og umhverfislega sjálfbærni, með fjölda aðstöðu CommScope um allan heim sem eru vottuð í samræmi við alþjóðlega staðla, þar á meðal ISO 9001, TL 9000 og ISO 14001.

Frekari upplýsingar um skuldbindingu CommScope er að finna á: https://www.commscope.com/corporate-responsibility-and-sustainability/.

Samskiptaupplýsingar
Heimsæktu okkar websíðuna eða hafðu samband við CommScope fulltrúa þinn til að fá frekari upplýsingar.

Fyrir tæknilega aðstoð, þjónustu við viðskiptavini eða til að tilkynna um týnda/skemmda hluta skaltu heimsækja okkur á: http://www.commscope.com/SupportCenter Or Contact PartnerPRO Network Partner https://www.commscope.com/partners/

Þessi vara kann að falla undir eitt eða fleiri bandarísk einkaleyfi eða erlend jafngildi þeirra. Fyrir einkaleyfi, sjá www.cs-pat.com

Öryggisráðstafanir

When using this product, follow these safety precautions to reduce the risk of fire, electric shock, and injury:

  1. Never install communications wiring in wet locations unless designed for wet areas.
  2. Avoid installation during lightning storms due to the risk of electric shock.
  3. Avoid touching uninsulated communication wiring or terminals unless disconnected at the network interface.
  4. Ensure all wiring connected to the equipment meets local and national building codes and network wiring standards.

Algengar spurningar

Henta þessar spjöld til notkunar utandyra?

No, it is recommended to avoid installing communications wiring in wet locations unless specifically designed for such environments.

Hvaða verkfæri þarf til uppsetningar?

You will need a Phillips head screwdriver and a flat blade screwdriver with a maximum diameter of 2.9mm.

Skjöl / auðlindir

COMMSCOPE CPP-UDDM-SL-1U-24 Unshielded Discrete Distribution Module [pdfUppsetningarleiðbeiningar
CPP-UDDM-SL-1U-24, CPP-UDDM-SL-2U-48, CPPA-UDDM-SL-1U-24, CPPA-UDDM-SL-2U-48, CPPR-UDDM-SL-1U-24, CPPR-UDDM-SL-2U-48, CPP-UDDM-SL-1U-24 Unshielded Discrete Distribution Module, CPP-UDDM-SL-1U-24, Unshielded Discrete Distribution Module, Discrete Distribution Module, Distribution Module

Heimildir

Skildu eftir athugasemd

Netfangið þitt verður ekki birt. Nauðsynlegir reitir eru merktir *