Elitech RCW-360 hita- og rakastigsgagnaskráningartæki

Notkunarleiðbeiningar fyrir vöru
- The product offers features such as real-time monitoring, alarm functions, data recording, and a large screen display.
- Refer to the provided figure for the different components of the product interface.
- The product model is RCW-Pro. Choose probe models based on the required specifications as listed in the table.
- Ýttu á Valmynd takkann til að view maximum and minimum values in the recorded data.
- Access the Record and Upload Interval page to adjust settings through the APP.
- Athugaðu upplýsingar um tækið með því að ýta á Valmyndarhnappinn til að view upplýsingar eins og gerð, skynjaraútgáfa, GUID, IMEI o.s.frv.
- Follow instructions in the Elitech iCold manual to add devices to the platform using the APP or WEB viðskiptavinur.
LOKIÐVIEW
- This product is a wireless Internet of Things monitor, providing such functions as real-time monitoring, alarm, data recording, data uploading, large screen display, etc. of temperature and humidity at monitoring points.
- Together with the “Elitech iCold” platform and APP, it can realize functions such as remote data viewing, historical data query, remote alarm push, etc.
- It is widely used in food, medicine, catering, international warehousing and logistics industries.
Eiginleikar
- Varan er hentug fyrir ýmis tækifæri, þar á meðal vöruhús, kæligeymslu, kælibíl, skuggaskáp, lyfjaskáp, kælistofu osfrv;
- Compact size, fashionable appearance, magnetic card tray design, and easy installation.
- Stór TFT litaskjár, ríkur af efni;
- Innbyggð endurhlaðanleg litíum rafhlaða gerir gagnaupphleðslu í langan tíma í rauntíma eftir rafmagnsleysi;
- Built-in sound-light alarm device can realize a local alarm.
- Sjálfvirk kveiking/slökkvun á skjánum;
- Styður allt að 2 rásir, hver rás styður ýmsar gerðir af tengibúnaði, sjá lista fyrir gerðir af mælitækjum.
Viðmót

| (1) External probe 1 | (2) Kveikja/slökkva hnappur | (3) Magnetic card tray |
| (4) SIM card interface(4G Version) | (5) Hleðsluviðmót | (6) External Probe 1 Interface |
| (7) Hleðsluvísir | (8) Alarm status indicator | (9) Skjár |
| (10) External probe 2 | (11) “Menu” button | (12) External Probe 2 Interface |
Listi yfir líkanaval
Collection Host: RCW-360Pro.
Ábendingar: The specific host model is subject to the actual product.
Probe model: The conventional probe models are shown in the table below:
| Gerð rannsaka | Einn hitastig | Tvöfalt hitastig | Hitastig gelflöskunnar | Hitastig og raki | Ofurlágt hitastig | Low Concentration CO2 | High Concentration CO2 |
| Fyrirmynd | TD3X-TE-R | TD3X-TDE-R | TD3X-TE(GLE)-R | TD3X-THE-R | PT100IIC-TLE-R | SCD4X-CO2E | STC3X-CO2E |
| Kapall | 5 metrar | 5 metrar | 5 metrar | 5 metrar | 3 metrar | 2 metrar | 2 metrar |
| Punktur | Einn hitamælir | Two temperature probes | Einn hitamælir | 1 hitamælir og 1 rakamælir | Einn hitamælir | CO2 styrkur | CO2 styrkur |
| Svið | -40~0°C | T: -40~ 0°C H: 0~100 %RH | -200~150°C | 400~ 5000 ppm | 0~100 vol% | ||
| Nákvæmni | ±0.5°C | T: ±0.5°C, H: ±5%RH | ±0.5°C(-40~ 0°C)
±1°C(- 0~100°C) ±2°C(Others) |
±(100+5% reading) | ±(1+3% reading) | ||
| Gerð skynjara | Digital temperature and humidity sensor, Digital temperature sensor | Analog to digital sensor | Koltvísýringsskynjari | ||||
| Viðmót skynjara | 3.5mm four-section headphone interface, using I2C communication mode | ||||||
Athugið:
- The specific sensor type is subject to the actual product.
- Vélbúnaðurinn er ekki með mælieiningum sem staðalbúnaður. Veldu mælieiningar eftir raunverulegum þörfum og hver rás getur aðlagað sig að ofangreindum gerðum mælieininga.
Tæknilegar breytur
- Aflgjafi: 5V/2A (DC), gerð-C.
- Temperature display resolution: 0.1 oc.
- Humidity display resolution: 0.10/0RH.
- Fjöldi hópa fyrir upptökur án nettengingar: 100,000.
- Gagnageymsluhamur: hringlaga geymsla.
- Upptaka, upphleðslutímabil og viðvörunartímabil:
- Normal recording interval: 1 minute, 24 hours allowed, Default 5 minutes.
- Alarm recording interval: 1 minute, 24 hours allowed, Default 2 minutes.
- Normal upload interval: 1 minute, 24 hours allowed, Default 5 minutes.
- Alarm upload interval: 1 minute, 24 hours allowed, Default 2 minutes.
- Rafhlöðuending:
- Not less than 10 days (@250°C, good network < environment, upload interval:5 minutes)
- Not less than 60 days (@250°C, good network environment, upload interval:30 minutes)
- Vísirljós: viðvörunarvísir, hleðsluvísir.
- Skjár: TFT litaskjár.
- Hnappar: kveikja/slökkva, valmynd.
- Viðvörunarhljóð: Viðvörun heyrist í 1 mínútu.
- Communication: 4G(can fall back to 2G), WlFl.
- Staðsetningarstilling: LBS + GPS (valfrjálst).
- Viðvörunarstillingar: staðbundin viðvörun og skýjaviðvörun.
- Vatnsheldni: IP64.
- Working environment: -20-60 oc, 0-900/0 RH (non-condensing).
- Upplýsingar og stærð: 110x70x23mm.
Notkunarleiðbeiningar
Uppsetning og fjarlæging rannsakandans
- Turn off the device and securely install the sensor in the headphone connector.
- To removing the sensor, please turn it off first and then unplug the sensor.
Hleðsla
- Tengdu við straumbreytinn með USB snúru.
- When charging, the charging indicator flashes; when it is fully charged, the charging indicator is always on.
Kveikt/slökkt
- Press and hold the on/off button for 3 seconds to turn on or off the device.
- Start recording data according to the recording interval after turning on, and report data according to the upload interval.
- Stop recording after turning off.
Rauntíma gögn

- Táknmynd fyrir netmerki: Tengstu við grunnstöðina og birtu merkjastika. Ef nettenging tækisins er óeðlileg birtist „X“ í efra vinstra horninu á merkinu.
- Rásarauðkenni: Táknað með CH1 eða CH2, sem gefur til kynna könnunargögnin sem samsvara rás 1 eða 2 fyrir núverandi gögn.
- Real-time temperature or humidity: Supports °C or °F display. If the platform turns off the probe, the corresponding position will display “OFF”.
- Efri og neðri viðvörunarmörk: Gögn undir neðri mörkum verða birt með bláu og gögn yfir efri mörkum verða birt með rauðu.
- Fjöldi gagna sem ekki hafa verið hlaðið upp: Sýnir fjölda skráðra en ekki hlaðinna gagna.
- Battery icon: Four-bar battery indicator. When charging, the battery indicator flashes and remains on when fully charged. When the battery level is below 20°/°, it is displayed in red.
- Tími og dagsetning
When both channels are connected with probes, the CH1 and CH2 channel data automatically switch display within 10 10-second cycle.
Hámark og lágmark
- Short-press the “Menu” key to enter the “Maximum and Minimum” page, as shown in the following figure.
- Count the maximum and minimum values in the recorded data. CH1A and CH1B represent the two collected values of channel 1 or 2, corresponding to sensor shutdown or single temperature probe. The B data displays “-~-“.

Viewskráningar og upphleðslutímabil
- Short-press the “Menu” button to enter the “Record and Upload Interval” page, as shown in the following figure, which can be set through the APP.

View upplýsingar um tæki
- Press the “Menu” button to enter the “Device Information” page, as shown in the following figure.
- You can query the model, Sensor, version, GUID, IMEI, SIM card ICCID(only for Wi-Fi version)

Að bæta tækjum við kerfið og grunnaðgerðir
- Adding devices to the platform and operation, please refer to “IV Elitech iCold”.
Elitech iCoId
- The Elitech iCold Cloud platform supports two methods for adding and managing devices:
- APP eða WEB client. The following mainly introduces the APP method. The WEB viðskiptavinur getur skráð sig inn á new.i-elitech.com fyrir rekstur.
Sæktu og settu upp APP
- Vinsamlegast skannaðu QR kóðann á forsíðu handbókarinnar eða leitaðu í Elitech iCold APP Store eða Google Play til að hlaða niður Elitech appinu.
Skráning reiknings og innskráning í appið
- Open the APP, in the login page, as shown in Figure 1, follow the prompts, enter the verification information, and click “Login”. After entering the APP, select “
“.
PS:
- If you not have an account, please click on “Register” in the login page, as shown in Figure 2, follow the prompts, and enter verification information to complete account registration.
- If you forget the password, click “Forget password” to find the password as shown in Figure 3. According to the prompts to finish verification and find out the password.

Bæta við tæki
- Smelltu á “
” í efra hægra horninu - Smelltu á “
” in the upper right corner, scan the QR code or enter the GUID back on the device, then fill in the device name and choose time zone. - Smelltu á “
”, the device is added.

Ábending: If the device shows one after being added to the platform, first check the network icon and offline records on the device. If everything is normal, please wait for a few minutes or restart the device before turning it on. The device uploads data according to the set reporting cycle. If the device is offline for a long time, please check if the SIM card is overdue. Ultimately unable to resolve, please call the service hotline for consultation.
Þráðlaust net (aðeins WIFI útgáfa)
- Ýttu stutt á „Menu“ takkann til að fara á síðuna „Upplýsingar um tæki“.
- Press and hold the “Menu” key, and a Bluetooth icon”
„mun birtast í efra vinstra horninu á tækinu“ - Use the app to distribute the network with this device via Bluetooth, as shown in the following figures ① ~ ③

Stilla gerð rannsakanda
- When using the device for the first time or changing the probe type, it is necessary to reconfigure the probe, as shown in Figure 4 and Figure 5 for operation.
Aðferðaraðferð: Log in to the APP →select the device to be changed →select “Parameter Configuration” →select “User Parameters” →select the corresponding probe model based on the actual selected probe type and channel →click “SET”.

Athugið:
- Eftir að gerð könnunar hefur verið endurskilgreind er nauðsynlegt að bíða eftir upphleðsluferli til að samstilla gerð könnunar við tækið, eða hægt er að endurræsa tækið til að samstilla strax.
- Skiptu um mæli. Vegna tímamismunarins á milli þess að skipta um mæli og stilla hann upp gætu verið gölluð gögn í gagnalistanum.
Tækjastjórnun
- Click on the device on the main page of the APP to enter the device management related page.
- Þú getur view upplýsingar um tæki, breyta nöfnum tækja, view gagnalistar, stilla efri og neðri mörk viðvörunar, skráningar-/upphleðslutímabil, stilla viðvörunarþrýsting, view maps, export reports, and perform other operations.

Elitech iCold pallur
- Fyrir fleiri aðgerðir, vinsamlegast skráðu þig inn á Elitech iCold Platform: new.i-elitech.com.
Áfylling
- Free data & advanced platform service will be activated after the device is first registered to the Elitech platform.
- After the probation period, customers need to recharge the device by referring to the operation manual.
Elitech iCold pallur: new.i-elitech.com

Algengar spurningar
- Sp.: Hvaða tegundir skynjara er hægt að nota með RCW-Pro skjánum?
- A: The monitor supports various sensors, including digital temperature and humidity sensors, analog-to-digital sensors, and carbon dioxide sensors.
- Sp.: Hvernig get ég stillt upptökutímabilin?
- A: You can adjust normal recording, alarm recording, normal upload, and alarm upload intervals through the settings on the device or via the APP.
Skjöl / auðlindir
![]() |
Elitech RCW-360 hita- og rakastigsgagnaskráningartæki [pdfNotendahandbók RCW-Pro, TD X-TE-R, TD X-TDE-R, TD X-TE GLE-R, TD X-THE-R, PT IIC-TLE-R, SCD X-CO E, STC X-CO E, RCW-360 hita- og rakastigsskráningartæki, RCW-360, hita- og rakastigsskráningartæki, og rakastigsskráningartæki, rakastigsskráningartæki, gagnaskráningartæki |