ELSYS EXT-Module Wireless Sensors

Tæknilýsing
- Vöruheiti: EXT-eining
- Gerð: EXT-Module, Rev C
- Útgáfudagur: 29.04.2025
- Inntak Voltage: Ytri afl inn, 5-24V
- Output Voltage: On/off or 0-10V output
- Constant Output: 3.3V
- Úttaksstraumur: Max 10mA @ 12V in, max 5mA @ 24V in
- Þráðlaus tenging: Compatible with ELT LoRa
Notkunarleiðbeiningar fyrir vöru
Uppsetning
- Ensure the ELT LoRa device is powered off before installing the EXT-Module.
- Insert the EXT-Module into the designated slot inside the ELT LoRa device.
- Connect external power input (5-24V) to the designated port on the EXT-Module.
- Make necessary connections for sensors or actuators as per your application requirements.
- Power on the ELT LoRa device and verify proper functionality of the EXT-Module.
Notkunarstillingar
- The EXT-Module can be used in two primary modes.
- Class C Device: For connecting external power and actuators, set the EXT-Module accordingly.
- Class A Device: For connecting sensors, configure the EXT-Module to operate as a class A device.
Úttaksstilling
- The EXT-Module offers on/off or 0-10V output options. For 0-10V output, ensure the external power supply is at least 11V.
Þráðlaus tenging
- The EXT-Module is designed to wirelessly connect to the ELT LoRa device for seamless data transmission from sensors or actuators.
INNGANGUR
- The EXT-module is a module that fits inside the ELT LoRa and is intended for connecting external power and actuators, and is used as a class C device. It can also connect to sensors and be used as a class A device.
Efst view
Eiginleikar
- Tengi fyrir utanaðkomandi rafmagn
- Kveikt/slökkt úttak
- 0 – 10 V úttak
- General-purpose input
- Passar inni í ELT-2 kassanum
- Knýr ELT-2
- Switching between functions is done with jumpers.
Neðst view

Tæknilýsing
- Inntak binditage: 5 – 24 V DC
- On/Off output: Hámark 0.7 A
- 0 – 10 V úttak: Hámark 5 mA
- Hægt er að skala inntak til að leyfa allt að 50 V
WRINGSKYNNING
- On/off or 0-10V output (for 0-10V, ext. power needs to be at least 11V)
- Ytri afl inn, 5-24V
- Input to ELT LoRa. 10 or 50V range.
- Connect a 500 ohm resistor between the inputs for 4-20mA (10V range)
- Stöðugt 3.3V úttak. Hámark 10mA @ 12V tommur, hámark 5mA @ 24V tommur

- Electronic systems in Umeå AB Tvistevägen 48, 90736 Umeå, Sweden
- Tölvupóstur: info@elsys.se
- Web: www.elsys.se
- Forskriftir í þessu skjali geta breyst án fyrirvara.
- ©Electronic systems in Umeå AB 2023
Algengar spurningar
Hvert er hámarks inntak voltage supported by the EXT-Module?
The EXT-Module supports an input voltage range of 5-24V for external power sources.
How can I configure the EXT-Module for sensor usage?
To use the EXT-Module with sensors, set it to operate as a Class A device and make the necessary sensor connections as per the provided instructions.
Hver er ráðlagður úttaksmagntage for actuators?
The EXT-Module provides an on/off or 0-10V output option. For actuators, you can use either mode based on your requirements.
Skjöl / auðlindir
![]() |
ELSYS EXT-Module Wireless Sensors [pdfLeiðbeiningarhandbók EXT-Module Wireless Sensors, EXT-Module, Wireless Sensors, Sensors |