EPH CONTROLS TR1V2-TR2V2 RF aðalrofi

Tæknilýsing
- Aflgjafi: 200 – 240VAC 50-60Hz
- Einkunn tengiliða: 230 Vac 10(3)A
- Umhverfishiti: 0…45˚C
- Sjálfvirk aðgerð: Type 1. C.
- Tækjaflokkar: Flokkur II tæki

- Mengunarstig: Mengunargráða 2
- IP einkunn: IP20
- Metið Impulse Voltage: Viðnám gegn binditage bylgja 2500V samkvæmt EN 60730
Hvernig TR1 TR2V2 virkar
- Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
- The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
- When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
- It is possible to send a wireless signal in one direction or both.
- When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
- When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
- Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
- It is possible to have more than one set of TR1, TR2V, 2and, where required.
- Please see pages 9-13 for wiring examples
Innra raflagnamynd fyrir TR1TR2V2
VARÚÐ: Installation should only be carried out by a qualified person and by wiring regulations.
Switching Options
Rafmagnsrofi
- Link L to 3
Lágt binditage Skipt
- Remove the external controls link from the boiler PCB.
- Connect 2 and 3 to these terminals.
Uppsetning og uppsetning
- The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
- Single-gang recessed back box.
- Yfirborðsfestingarboxar
- Directly mounted on a wall.
- Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
- Screw the backplate to the wall with the screws provided.
- Tengdu bakplötuna í samræmi við raflögn.
- Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m



Hnappur / LED Lýsing

Handbók Press to activate or deactivate the Live out terminal.
Tengdu Hold for 3 seconds to initialise the pairing process. The RF light will flash.
Endurstilla Press to reset the T, R1, TR2V2.
Athugið: The connection procedure is not required as both TR1 & TR2V2 are pre-paired
LED Lýsing
| LED | Litur | Lýsing |
| Lifðu í LED | Rauður | Það er ekkert binditage on the Live terminal. |
| Grænn | Það er voltage á Live in tengi – Nú verður RF merki sent í hinn RF aðalrofann til að virkja Live út tengið. | |
| RF LED | Hvítur | Fast hvít ljósdíóða sem gefur til kynna að hitastillirinn sé tengdur. |
| RF ljósið blikkar tvöfalt þegar hitastillirinn er aftengdur. Athugaðu pörun hitastilla. | ||
| Athugið: RF ljósið mun blikka með hléum þegar kerfið er að senda og taka á móti merki um samskipti. | ||
| Athugið: The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state. | ||
| Lifandi LED | Rauður | Ekkert RF-virkjunarmerki hefur borist frá hinum RF-aðalrofanum. |
| Grænn | RF activation signal has been received from the other RF Mains Switch. |
To connect the TRI TR2V2
Vinsamlegast athugið: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.
On TR1V2:
- Haltu
for 3 seconds until the RF LED flashes white.
On TR2V2:
- Haltu
í 3 sekúndur. - The RF LED will begin to flash, and the Live out LED will appear solid green.
- When connected, all three LEDs will appear solid.
On TR1V2:
- Ýttu á
to exit the pairing mode. - After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.
To disconnect the TRI TR2V2
- Haltu
for 3 seconds until the RF LED flashes white. - Haltu
for 10 seconds until the Live in LED appears solid red.
On TR2V2:
- Haltu
for 3 seconds until the RF LED flashes white. - Haltu
Connect for 10 seconds until the Live in & Live out LED appears solid red.
On TRIV2:
- Ýttu á
að hætta. - The TRI TR2V2 is now disconnected.
Raflögn Examples
Example One way RF Switch: Programmer to Boiler – Mains Switching
TR1V2
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.
Uppsetningarskýringar
- Mains Switching Boiler
- Lágt binditage Switching Boiler
- Á TR2V2
- On the boiler PCB
- Á TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
Example 2 Two Two-way RF Switch:
- Programmer to Motorised Valve
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

Uppsetningarskýringar
1. Main Switching Boiler
2. Lágt binditage Switching Boiler
3. Rafknúinn loki
- On the TRIV2
- On the boiler PCB
- On the TRIV2
- Á TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the motorised valve.
Example 3 One way RF Switch:
Pump Overrun – Mains Switching
TR 1 v2
- On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

Uppsetningar athugasemd
- Dæla á
- the TR2V2
- Link L to 3 to power the Live out terminal to the pump
Example 4 Two Two-way RF Switch: Pump Overrun
- Forritari að katli
- Boiler to Pump – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the pump.
TR2V2
- On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Uppsetningar athugasemd
- Mains Switching Boiler
- Lágt binditage Switching Boiler
- Dæla
- Á TR2V2
- On the boiler PCB –
- Á TR2V2
- On the TRIV2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the pump.
Example 5 Two Two-way RF Switch: Unvented Cylinder:
- Forritari fyrir hitastilli með hámarksgildi
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out the contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Uppsetningarskýringar
- Mains Switching Boiler
- Lágt binditage Switching Boiler
- High Limit hitastillir
- Vélknúinn loki
- On the TRIV2
- On the boiler PCB
- Á TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the High Limit thermostat.
EPH stýrir IE
tækni@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665
EPH Controls Bretlandi
tækni@ephcontrols.co.uk
www.ephcontrols.co.uk/
hafðu samband við okkur
+44 1933 322 072
Harrow, HAI IBD
Algengar spurningar
Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.
Sp.: Hver er hámarksfjarlægðin milli TR1V2 og TR2V2 fyrir skilvirk samskipti?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.
Skjöl / auðlindir
![]() |
EPH CONTROLS TR1V2-TR2V2 RF aðalrofi [pdfLeiðbeiningarhandbók TR1V2, TR2V2, TR1V2-TR2V2 RF aðalrofi, TR1V2-TR2V2, RF aðalrofi, Aðalrofi, Rofi |