CL-3DA2306E is a new generation of digital three-phase closed-loop stepper driver developed based on 32-bit DSP technology. The driver adopts a new structure and control scheme, and a new interface scheme, making it more convenient and faster for users to use. The driver combines more advanced Algorithm, greatly reduces the noise of the motor during operation, making the motor run more smoothly and reliably。
Vörulýsing
- Voltage input range: AC150V~250V
- Hámarks hámarksstraumur: 6.0A
- Segmentation range: 400~60000ppr
- Pulse form: pulse + direction (double pulse is not supported)
- Impulse response frequency: 0~200kHz
- Með overvoltage, ofstraumur, fasatap mótorsins og aðrar verndaraðgerðir
Uppsetningarstærðir

Kafli 2 Rafmagnstengingar og stillingar
| Flugstöð nr. |
Nótaskrift |
Skýring |
| 1 | NC | tómir fætur |
| 2 | U |
Þriggja fasa skrefmótorvinding |
| 3 | V | |
| 4 | W | |
| 5 | PE | jörð |
| 6 | AC | AC power input AC150V~250V |
| 7 | AC |
Control signal terminal block
| Flugstöð nr. |
Nótaskrift |
Skýring |
| 1 | PUL+ | Inntakstenging púlsmerkis (5V-24V) |
| 2 | PUL- | |
| 3 | DIR+ | Inntakstenging fyrir stefnumerki (5V-24V) |
| 4 | DIR- | |
| 5 | ENA+ | Inntakstenging losunarmerkis (5V-24V) |
| 6 | ENA- | |
| 7 | ALM+ | Alarm signal output terminal Normally closed output |
| 8 | ALM- | |
| 9 | RDY+ | Be ready signal output terminal
Venjulega lokað úttak |
|
10 |
RDY- |
Encoder signal terminal block
| Flugstöð nr. |
Nótaskrift |
Skýring |
| 1 | EA+ | Fasaviðbragðsmerki frá kóðara |
| 2 | EA- | |
| 3 | EB+ | Viðbragðsmerki B-fasa kóðara |
| 4 | EB- |
| 5 | EZ+ | Encoder Z phase feedback signal
(Default is not connect) |
| 6 | EZ- | |
| 7 | +5V | Jákvæð aflgjafi kóðara |
|
8 |
GND |
Aflgjafi fyrir kóðara
neikvæð |
Leiðbeiningar um raflögn
Input signal wiring diagram (input supports 5-24V voltage)

Output signal wiring diagram

Signal control timing diagram

Vinsamlegast athugið:
t1 and t2 should be greater than 5us; when SW10 is ON, t1 and t2 should be greater than 2ns.
t3 and t4 should be greater than 1ms.
Hnappvirknilýsing
Introduction to debugging panel

Gagnavöktun

Starfsferlar

- Endurheimta factory settings: Press the key
to switch to “AF_Ini”, then press the key
to display “InI -”, and then press the key
When “FiniSh” appears, the setting is completed. 。 - Hreinsa alarm : Press the key
to switch to “AF_CLr”, then press the key
to display “CLr -”, and then press the key
, When “FiniSh” appears, the setting is completed. - Parameter writing: Press the key
til að skipta yfir í „EE_SEt“, ýttu síðan á takkann
to display “EEP -”, and then press the key
í 5 sekúndur. Þegar „FiniSh“ birtist er stillingunni lokið.
Færibreytulýsing
| Heimilisfang | Parameter | Sjálfgefið
t value |
Svið | Skýring |
| PA00 | Number of given pulses per motor
byltingu |
4000 | 400~51200 | P |
| PA01 | Number of feedback pulses per code
wheel revolution |
4000 | 4000~6553
5 |
P |
| PA02 | Open loop standby current
prósenttage |
60 | 0~100 | % |
| PA03 | Lokað lykkjustraumprósentatage | 100 | 0~100 | % |
| PA04 | Input pulse smoothing enable | 1 | 0~1 | 1 permit |
| PA05 | Inntaks púls jöfnunartími | 12800 | 0~25600 | us |
| PA06 | Rekstrarstillingar | 1 | 0~1 | 0/open loop,
1/closed loop |
| PA07 | Manufacturer parameters 1 | 75 | 30-100 | % |
| PA08 | Motor self-identification setting after
kveikt |
1 | 0~1 | 1 permit |
| PA09 | Hlutfallsstuðull núverandi lykkja | 2000 | 200~32767 | |
| PA10 | Straumlykja samþættur stuðull | 200 | 10~32767 | |
| PA11 | Færibreytur framleiðanda | 4000 | 100~32767 | |
| PA12 | Position loop proportional coefficient | 4000 | 100~32767 | |
| PA13 | Færibreytur framleiðanda | 260 | 20~32767 | |
| PA14 | Hraðallykkja hlutfallsstuðull | 220 | 20~32767 | |
| PA15 | Færibreytur framleiðanda | 50 | 0~32767 | |
| PA16 | Speed feedforward compensation coefficient | 370 | 0~500 | |
| PA17 | Position out-of-tolerance threshold setting | 4000 | 1~65535 | P |
| PA18 | Frákaststími | 2 | 0~10000 | 50us |
| PA19 | Virkja stigrökfræði | 1 | 0~1 | 0 is positive logic,
1 is negative logic. |
| PA20 | Val á virkni útgangs 1 | 1 | 0~4 | 0 alarm, 2RDY, 4 in
place signal |
| PA21 | Val á rökfræði fyrir útgangstengingu 1 | 1 | 0~1 | 0 is positive logic,
1 is negative logic. |
| PA22 | Stilling á seinkun á bremsuútgangi | 100 | 0~2000 | ms |
| PA23 | In place output port function selection | 0 | 0~1 | 0 in place signal,
1 brake signal. |
| PA24 | Val á rökfræði fyrir úttaksgátt á staðnum | 0 | 0~1 | 0 is positive logic,
1 is negative logic. |
| PA25 | Færibreytur framleiðanda | 40 | ||
| PA26 | Færibreytur framleiðanda | 0 | ||
| PA27 | Positive direction input logic selection | 1 | 0~1 | 0 is positive logic,
1 is negative logic. |
| PA28 | In-position signal pulse limit setting | 5 | 1~1000 | P |
| PA29 | Færibreytur framleiðanda | 800 | 50~10000 | Hz |
| PA30 | Torque given filter cutoff frequency | 1000 | 50~5000 | Hz |
| PA31 | Speed feedback filter cutoff
tíðni |
100 | 10~1000 | Hz |
| PA32 | Speed given filter cutoff frequency | 160 | 10~1000 | Hz |
| PA33 | Færibreytur framleiðanda | 100 | 20~180 | % |
| PA34 | Manufacturer parameters 2 | 50 | ||
| PA35 | Færibreytur framleiðanda | 100 | 0~100 | % |
| PA36 | Power-on anti-jamming option | 0 | 0~1 | 0 cancel, 1 start |
| PA37 | Færibreytur framleiðanda | 21 | ||
| PA38 | Færibreytur framleiðanda | 75 | ||
| PA39 | acceleration feedforward | 70 | 0~1024 | |
| PA40 | Self-running speed setting | 60 | 0~5000 | 0.01 rps |
| PA41 | Self-run position setting | 100 | 0.01r | |
| PA42 | Self-run times setting | 1 | 0~32000 | |
| PA43 | Self-run starting direction setting | 1 | 0~1 | |
| PA44 | Self-running interval setting | 100 | 1~5000 | ms |
| PA45 | Self-running one-way and two-way
stillingar |
1 | 0~1 | 0 one-way, 1 two-way |
| PA46 | Stillingar fyrir sjálfkeyrandi hröðun | 200 | 10~2000 | r/s/s |
| PA47 | Stillingar fyrir sjálfkeyrslu ræsingar | Set to 1 to start and automatically return to 0 after running. |
Kafli 3 Úrræðaleit
Algengar gallar og lausnir
| Viðvörunarkóði | Bilunarlýsing | Úrræðaleit |
|
ER 001 |
Yfirstraumsviðvörun |
|
|
ER 002 |
Yfirvoltage viðvörun |
|
| ER 004 |
Position deviation is too large |
|
|
ER 020 |
HARDWARE-CNC
- Eerste Molenweg 28a
- 1261TD Blaricum – Nederland
- Sími: +31(0)358888107
- Webhlið: WWW.HARDWARE-CNC.NL
- Tölvupóstur: Info@Hardware-CNC.nl
Skjöl / auðlindir
![]() |
Vélbúnaður CNC CL-3DA2306E þriggja fasa lokaða lykkju skrefdrif [pdfNotendahandbók CL-3DA2306EUSERMANUALV2, CL-3DA2306EUSERMANUALV2, CL-3DA2306E Þriggja fasa lokaða lykkju skrefastýring, CL-3DA2306E, Þriggja fasa lokaða lykkju skrefastýring, Lokað lykkju skrefastýring, Lykkju skrefastýring, Skráastýring, Drif |