L3 campus Stackable Managed Switch
„
Tæknilýsing
- Gerð: Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
LED - LED vísbending:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
almennilega) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Notkunarleiðbeiningar fyrir vöru
Kafli 2: Uppsetning
Áður en þú byrjar uppsetningarferlið skaltu ganga úr skugga um að þú hafir allt
the necessary tools and follow safety precautions.
- Innihald pakka: Check all items mentioned in
pakkann. - Öryggisráðstafanir: Follow the guidelines to
tryggja örugga uppsetningu. - Uppsetningarverkfæri: Gather all tools required
til uppsetningar. - Uppsetning vöru: Fylgdu skrefinu fyrir skrefinu
instructions provided in the manual for successful
uppsetningu.
Kafli 3: Tenging
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
Kafli 4: Stillingar
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
þarfir.
Algengar spurningar
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
kafla í handbókinni til að fá frekari aðstoð.
“`
Viðskiptanetlausn
Uppsetningarleiðbeiningar
Ómada C.ampus Stackable L3 Managed Switch
Um þessa uppsetningarhandbók
Þessi uppsetningarhandbók lýsir vélbúnaðareiginleikum, uppsetningaraðferðum og þeim atriðum sem ætti að huga að við uppsetningu. Þessi uppsetningarhandbók er byggð upp á eftirfarandi hátt: Kafli 1 Inngangur Þessi kafli lýsir ytri íhlutum rofans. Kafli 2 Uppsetning Þessi kafli sýnir hvernig á að setja upp rofann. Kafli 3 Tenging Þessi kafli sýnir hvernig á að gera líkamlega tengingu rofans. Kafli 4 Stillingar Þessi kafli sýnir hvernig á að stilla rofann. Viðauki A Úrræðaleit. Viðauki B Forskriftir
Áhorfendur
Þessi uppsetningarhandbók er fyrir:
Netverkfræðingur
Netkerfisstjóri
Samþykktir
· Sumar gerðir sem fjallað er um í þessari handbók gætu ekki verið tiltækar í þínu landi eða svæði. Fyrir upplýsingar um sölu á staðnum, heimsækið https://www.omadanetworks.com/.
· Tölurnar í kafla 2, kafla 3 og kafla 4 eru eingöngu til sýnis. Rofi þinn gæti verið öðruvísi í útliti frá því sem sýnt er.
· Útreikningar PoE fjárhagsáætlunar eru byggðir á rannsóknarstofuprófum. Raunveruleg PoE orkufjárveiting er ekki tryggð og mun vera breytileg vegna takmarkana viðskiptavina og umhverfisþátta.
· Þessi handbók notar sérstök snið til að auðkenna sérstök skilaboð. Eftirfarandi tafla sýnir tilkynningartákn sem eru notuð í þessari handbók.
Minntu á að fara varlega. Varúð gefur til kynna möguleika sem geta leitt til tjóns á tækinu.
Minnum á að taka eftir. Athugasemdin inniheldur gagnlegar upplýsingar til betri notkunar vörunnar.
Tengt skjal
Notendahandbók og CLI tilvísunarhandbók vörunnar eru í niðurhalsmiðstöðinni. Til að fá nýjustu vöruupplýsingar, farðu á opinbera websíða: https://support.omadanetworks.com/document/.
Innihald
1. kafli Inngangur ———————- 01
1.1 Vara lokiðview …………………………………………………………..01 1.2 Útlit……………………………………………………………………..01
2. kafli Uppsetning ———————- 12
2.1 Innihald pakka …………………………………………………..12 2.2 Öryggisráðstafanir …………………………………………………………12 2.3 Uppsetningarverkfæri…………………………………………………………..14 2.4 Uppsetning vöru ………………………………………………………..14
3. kafli Tenging ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Kafli 4 Stillingar ——————– 27
4.1 Stillingu lokiðview…………………………………………27 4.2 Sjálfstæður hamur…………………………………………………………27 4.3 Stjórnandi hamur………………………………………………………………28
Viðauki A Úrræðaleit —————- 32
Viðauki B Forskriftir —————— 33
Ómada C.ampus Stackable L3 Managed Switch
1. kafli Inngangur
1.1 Vara lokiðview
Hannað fyrir fyrirtæki og campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampLesin felur í sér að knýja netmyndavélar, aðgangsstaði fyrir þráðlaust staðarnet, IP síma, netmiðstöðvar, innbyggðar tölvur o.s.frv.
1.2 Útlit
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 tengi
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED
Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 tengi
10G SFP+ Slot LED
Inngangur 01
Ómada C.ampus Stackable L3 Managed Switch
LED vísbending
PWR1*
PWR2
Grænt á
Slökkt
Grænt á
Gulur á**
Slökkt
Grænt á
Slökkt
Slökkt
Vísbending
Rofinn er knúinn af PWR1. PWR2 er aftengdur eða hann virkar ekki rétt.
Rofinn er knúinn af PWR1. PWR1 og PWR2 eru tengdir.*
Rofinn er knúinn af PWR2. PWR1 er aftengdur eða hann virkar ekki rétt.
Slökkt er á rofanum eða bæði PWR1 og PWR2 virka ekki rétt.
LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Þegar kveikt er á STK LED)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Vísbending
Blikkandi: Rofi virkar rétt. Kveikt eða slökkt: Rofinn virkar ekki rétt.
Green On: Allar viftur virka rétt. Gult kveikt: Ekki eru allir viftur sem virka rétt.
Kveikt: Tæki er tengt við tengið. Blikkandi: Sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við tengið.
Kveikt: Tækið virkar sem aðalrofi í staflakerfinu eða virkar sjálfstætt. Slökkt: Tækið virkar sem meðlimarrofi í staflakerfinu.
Grænn á: Keyrir á 1000 Mbps, en engin virkni. Grænt blikkandi: Keyrir á 1000 Mbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 10Mbps/100 Mbps, en engin virkni. Gult blikkandi: Keyrir á 10Mbps/100 Mbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Kveikt: Gáttarnúmerið gefur til kynna auðkenni einingarinnar í staðfræði stafla.
Grænt kveikt: Keyrir á 10 Gbps, en engin virkni. Grænt blikkandi: Keyrir á 10 Gbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 1 Gbps, en engin virkni. Gult blikkandi: Keyrir á 1 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Þegar bæði PWR1 og PWR2 virka rétt og rofinn er knúinn af PWR1, tekur það 10-20 sekúndur fyrir LED PWR2 (gult) að slokkna eftir að PWR2 hefur verið aftengt.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Inngangur
Ómada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 tengi
10G SFP+ Slot LED
Framhlið S6500-48GP6XF er sýnt sem eftirfarandi mynd.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
1G RJ45 tengi
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 tengi
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 tengi
25G SFP28 Slot LED
Inngangur 03
Ómada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 tengi
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB2.0 Port (Type-C/RJ45)
2.5G RJ45 tengi
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST
Vísbending
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Blikkandi: Rofi virkar rétt. Kveikt eða slökkt: Rofinn virkar ekki rétt.
Green On: Allar viftur virka rétt. Gult kveikt: Ekki eru allir viftur sem virka rétt.
Kveikt: PoE-afl sem eftir er er 7 W. Blikkandi: PoE-afl sem eftir er heldur 7 W eftir að kveikt er á þessari LED í 2 mínútur. Slökkt: PoE-afl sem eftir er er > 7 W.
Kveikt: Tæki er tengt við tengið. Blikkandi: Sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við tengið.
Kveikt: Tækið virkar sem aðalrofi í staflakerfinu eða virkar sjálfstætt. Slökkt: Tækið virkar sem meðlimarrofi í staflakerfinu.
04 Inngangur
Ómada C.ampus Stackable L3 Managed Switch
LED
Vísbending
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
Grænn á: Keyrir á 1000 Mbps, en engin virkni. Grænt blikkandi: Keyrir á 1000 Mbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 10Mbps/100 Mbps, en engin virkni. Gult blikkandi: Keyrir á 10Mbps/100 Mbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Þegar kveikt er á STK LED)
Kveikt: Gáttarnúmerið gefur til kynna auðkenni einingarinnar í staðfræði stafla.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Þegar PoE LED er á)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Grænt kveikt: Keyrir á 10 Gbps, en engin virkni. Grænt blikkandi: Keyrir á 10 Gbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 1 Gbps, en engin virkni. Gult blikkandi: Keyrir á 1 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Grænt kveikt: Keyrir á 25 Gbps, en engin virkni. Blikkandi grænt: Keyrir á 25 Gbps og sendir eða tekur á móti gögnum. Gult kveikt: Keyrir á 1 Gbps/10 Gbps, en engin virkni. Blikkandi gult: Keyrir á 1 Gbps/10 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Inngangur 05
Ómada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Stjórnunarhöfn
LED
Console Port USB3.0 Port
(RJ45/Type-C)
Stillingarval
Hnappur
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Hnappur til að velja stillingu
Stjórnunarhöfn
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
Stjórnunarhöfn
LED
USB3.0 tengi
Console Port
(RJ45/Type-C)
Hnappur til að velja stillingu
25G SFP28 rauf
LED
(Höfn 1-24)
The front panel of S7500-48Y8C is shown as the following figure.
100G QSFP28 rauf (tengi 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Inngangur
100G QSFP28 rauf (tengi 49-56)
Ómada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Hnappur til að velja stillingu
Stjórnunarhöfn LED
USB3.0 tengi
Console Port (Type-C/RJ45)
100G QSFP28 rauf
LED
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
SYS aðdáandi
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Þegar kveikt er á SPD LED)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Vísbending
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Blikkandi: Rofi virkar rétt. Kveikt eða slökkt: Rofinn virkar ekki rétt.
Grænn: Allar viftur virka rétt. Gulur: Ekki eru allir viftur sem virka rétt.
Kveikt: Tæki er tengt við tengið. Blikkandi: Sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við tengið.
Athugið:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Kveikt: Tækið virkar sem aðalrofi í staflakerfinu eða virkar sjálfstætt. Slökkt: Tækið virkar sem meðlimarrofi í staflakerfinu.
Grænt kveikt: Keyrir á 10 Gbps, en engin virkni. Grænt blikkandi: Keyrir á 10 Gbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 1 Gbps, en engin virkni. Gult blikkandi: Keyrir á 1 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Grænt kveikt: Keyrir á 25 Gbps, en engin virkni. Blikkandi grænt: Keyrir á 25 Gbps og sendir eða tekur á móti gögnum. Gult kveikt: Keyrir á 1 Gbps/10 Gbps, en engin virkni. Blikkandi gult: Keyrir á 1 Gbps/10 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Inngangur 07
Ómada C.ampus Stackable L3 Managed Switch
LED
Vísbending
Port 27-32 of S7500-26XF6Y ***
(Þegar kveikt er á SPD LED)
Grænt kveikt: Keyrir á 25 Gbps, en engin virkni. Blikkandi grænt: Keyrir á 25 Gbps og sendir eða tekur á móti gögnum. Gult kveikt: Keyrir á 1 Gbps/10 Gbps, en engin virkni. Blikkandi gult: Keyrir á 1 Gbps/10 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Grænt kveikt: Keyrir á 100 Gbps, en engin virkni. Grænt blikkandi: Keyrir á 100 Gbps og sendir eða tekur á móti gögnum. Gulur Kveikt: Keyrir á 40 Gbps, en engin virkni. Gult blikkandi: Keyrir á 40 Gbps og sendir eða tekur á móti gögnum. Slökkt: Ekkert tæki er tengt við samsvarandi tengi.
Athugið:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Þegar kveikt er á STK LED)
Kveikt: Gáttarnúmerið gefur til kynna auðkenni einingarinnar í staðfræði stafla.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Stjórnunartengi Hannað til að tengja tækið til stjórnunar í gegnum web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Inngangur
Ómada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Fyrirmynd
1000M
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
Rauf
Rauf
Höfn
Höfn
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Athugið: PWR1 er aðalaflgjafinn og hann hefur forgang fram yfir PWR2.
Inngangur 09
Ómada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington öryggisrifa
LED
Jarðtengingarstöð
Aflgjafaeining
LED
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Jarðtengingarstöð
LED
Power Supply Module Locking Strap Slot
LED
Kensington öryggisrifa
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
Aftari spjaldið á S7500-48Y8C er sýnt á eftirfarandi mynd. Myndin er eingöngu til sýnikennslu. Rofinn þinn gæti verið öðruvísi í útliti en sá sem sýndur er.
Jarðtengingarstöð
LED
LED
Læsingaról
Rauf
Aflgjafaeining
10 Inngangur
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Ómada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
LED LED
Locking Strap Slot
Kensington öryggisrauf fyrir aflgjafaeiningu
Jarðtengingarstöð
LED
Locking Strap Slot
Aflgjafaeining
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Inngangur 11
Ómada C.ampus Stackable L3 Managed Switch
Kafli 2 Uppsetning
2.1 Innihald pakka
Gakktu úr skugga um að pakkinn innihaldi eftirfarandi hluti. Vinsamlegast hafðu samband við dreifingaraðilann þinn ef eitthvað af upptaldri hlutum er skemmt eða vantar. Tölurnar eru eingöngu til sýnis. Raunverulegir hlutir geta verið mismunandi að útliti og magni frá þeim sem sýndir eru.
Skipta
Rafmagnssnúra og stjórnborðssnúra
Uppsetningarleiðbeiningar
Viðskiptanetlausn
Uppsetningarleiðbeiningar
Ómada C.ampus Stackable L3 Managed Switch
Festingarfestingar, skrúfur og gúmmífætur
2.2 Öryggisráðstafanir
Til að forðast skemmdir á tækinu og líkamstjóni af völdum óviðeigandi notkunar, ættir þú að virða eftirfarandi reglur.
Öryggisráðstafanir Haldið rafmagninu slökktu á meðan uppsetning stendur. Notið úlnliðsól sem verndar rafstuðningsrof og gætið þess að úlnliðsólin snerti vel húðina og sé
vel jarðtengd. Notið aðeins rafmagnssnúruna sem fylgir rofanum. Gakktu úr skugga um að rafmagnið sé rétt.tage passar við forskriftirnar sem tilgreindar eru á bakhlið vélarinnar
skipta. Gakktu úr skugga um að rofinn sé settur upp í vel loftræstu umhverfi og loftræstingargat hans er ekki
læst. Ekki opna eða fjarlægja hlífina á rofanum. Áður en þú hreinsar tækið skaltu slökkva á aflgjafanum. Ekki þrífa það með vatnskennda klútnum og aldrei
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Kröfur vefsins
Hitastig/Raki
12 Uppsetning
Ómada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Rykið sem safnast á rofanum getur frásogast af stöðurafmagni og valdið lélegri snertingu við málmsnertipunkta. Nokkrar ráðstafanir hafa verið gerðar fyrir tækið til að koma í veg fyrir stöðurafmagn, en of sterkt stöðurafmagn getur valdið banvænum skemmdum á rafeindahlutum á innri hringrásarborðinu. Til að forðast áhrif kyrrstöðurafmagns á virkni rofans skaltu leggja mikla áherslu á eftirfarandi atriði: Rykhreinsaðu tækið reglulega og haltu inniloftinu hreinu. Haltu tækinu vel jarðtengdu og tryggðu að stöðurafmagnið hafi verið flutt. Rafsegultruflanir
Rafrænir þættir, þar á meðal rýmd og sprautun á tækinu, geta orðið fyrir áhrifum af utanaðkomandi truflunum, svo sem leidinni losun með rafrýmdartengingu, inductance tengingu og viðnámstengi. Til að draga úr truflunum, vertu viss um að gera eftirfarandi ráðstafanir: Notaðu aflgjafa sem getur í raun síað truflun frá rafmagnsnetinu. Haltu tækinu fjarri hátíðni og sterkum straumbúnaði eins og útvarpssendingum
stöð. Notaðu rafsegulhlíf þegar þörf krefur. Eldingavörn
Uppsetning 13
Ómada C.ampus Stackable L3 Managed Switch
Einstaklega hátt voltagStraumar geta myndast samstundis þegar eldingar verða og loftið í rafhleðsluleiðinni er samstundis hægt að hita upp í 20,000 °C. Þar sem þessi augnabliksstraumur er nógu sterkur til að skemma rafeindatæki ætti að grípa til skilvirkari eldingavarna. Gakktu úr skugga um að rekki og tæki séu vel jarðtengd. Gakktu úr skugga um að rafmagnsinnstungan hafi góða snertingu við jörðu. Haltu sanngjörnu kapalkerfi og forðastu eldingar. Notaðu merki SPD (Surge Protective Device) þegar raflögn eru utandyra.
Athugið: Nánari upplýsingar um varnir gegn eldingum er að finna í leiðbeiningum um varnir gegn eldingum á: https://support.omadanetworks.com/r/1004/. Uppsetningarstaður
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Uppsetningarverkfæri
Phillips skrúfjárn ESD-fyrirbyggjandi úlnliðsbúnaður Kaplar
Athugið: Þessi verkfæri fylgja ekki með vörunni okkar. Ef þörf krefur geturðu keypt þau sérstaklega.
2.4 Uppsetning vöru
Rofinn er hannaður með hitaleiðni að framan til aftan. Þegar það virkar, þá dreifir loftið eins og sýnt er hér að neðan. Til að ná betri hitaleiðni skaltu setja tækið upp í vel loftræstu umhverfi og skilja eftir 5 til 10 cm bil í kringum tækið.
14 Uppsetning
Mynd 2-1
Loftrás
Ómada C.ampus Stackable L3 Managed Switch
Uppsetning á skjáborði
Til að setja upp tækið á skjáborðinu skaltu fylgja skrefunum:
1. Settu tækið á sléttan flöt sem er nógu sterkur til að bera allan þyngd tækisins með öllum innréttingum.
2. Fjarlægðu límbakpappírana af gúmmífótunum.
3. Festu gúmmífæturna við botn tækisins til að koma í veg fyrir að það renni þegar það er sett á borðborð.
Mynd 2-2
Uppsetning á skjáborði
Fætur Neðst á tækjahakinu
Uppsetning rekki
Pakkinn inniheldur 6 pör af mismunandi festingarfestingum, myndir þeirra eru sýndar hér að neðan og geta verið frábrugðnar raunverulegum vörum.
Mynd 2-3
Festingarfestingar
Skrúfuholuhópur 2
Bracket D Bracket C Bracket B Bracket A
Skrúfuholuhópur 1
Skrúfuholuhópur 3
Sviga F
Screw Hole Group 4-2 (for device with 420mm depth)
Skrúfuholuhópur 5
Skrúfugat
Hópur 4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Krappi E
Uppsetning 15
Ómada C.ampus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Aðferð
Sýning
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Fjarlægð rekka
(For device with a depth of 380mm)
Fjarlægð rekka
(For device with a depth of 420mm)
Fjarlægð rekka
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 Uppsetning
Ómada C.ampus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Til að setja upp tækið skaltu fylgja leiðbeiningunum sem lýst er hér að neðan:
1. Attach the M6 nuts to the racks.
Mynd 2-4
Að festa M6 hnetur
×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
Mynd 2-5
Uppsetning sviga á rekki
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Uppsetning 17
Ómada C.ampus Stackable L3 Managed Switch
Mynd 2-6
Setja upp festingar á rofa
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
Mynd 2-7
Uppsetning rofa á rekki
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 Uppsetning
Ómada C.ampus Stackable L3 Managed Switch
Uppsetning aflgjafaeiningar
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
Mynd 2-8
Útlit aflgjafaeiningarinnar
Rafmagnssnúru tengi
FAN
Festaklemmur
Útdráttarhandfang
LED
Locking Strap Slot Release Handle
Ef þú þarft að bæta við einni aflgjafaeiningu í viðbót, vinsamlegast fylgdu skrefunum:
1. Notið úlnliðsól sem verndar gegn rafstuðli (ESD) og gætið þess að hún snerti húðina vel og sé vel jarðtengd.
2. Ýttu á útdráttarhandfang einingarinnar með annarri hendi og haltu neðst á einingunni með hinni hendinni. Ýttu einingunni varlega inn eftir raufarleiðarlínunni.
3. Slepptu útdráttarhandfanginu til að festa aflgjafaeininguna á sínum stað.
Mynd 2-9
Setja upp aflgjafaeininguna
Losunarhandfang
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Notið úlnliðsól sem verndar gegn rafstuðli (ESD) og gætið þess að hún snerti húðina vel og sé vel jarðtengd.
Uppsetning 19
Ómada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Ef þú þarft að fjarlægja aflgjafaeininguna skaltu fylgja skrefunum:
1. Notið úlnliðsól sem verndar gegn rafstuðli (ESD) og gætið þess að hún snerti húðina vel og sé vel jarðtengd.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Uppsetning viftueiningar
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Mynd 2-11 Útlit viftueiningarinnar
LED
20 Uppsetning
Extraction Handle Retainer Clips Release Handle
Ómada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
jarðtengd. 2. Ýttu á útdráttarhandfangið á einingunni með annarri hendi og togaðu í það þar til
einingin kemur alveg út úr undirvagninum.
Mynd 2-12 Að fjarlægja skemmda viftueiningu
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Uppsetning 21
Ómada C.ampus Stackable L3 Managed Switch
3. kafli Tenging
3.1 Ethernet tengi
Tengdu Ethernet tengi rofans við tölvuna með RJ45 snúru eins og eftirfarandi mynd sýnir.
Mynd 3-1
Að tengja RJ45 tengið
RJ45 höfn
RJ45 kapall
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
Mynd 3-2
Inserting the Fiber Module
Slot Fiber Module
3.3 Stjórnborðshöfn
CLI (Command Line Interface) gerir þér kleift að stjórna rofanum, þannig að þú getur hlaðið CLI eftir að þú hefur tengt tölvur eða tengi við stjórnborðstengið á rofanum með snúru (RJ45 stjórnborðssnúra fylgir með, en Type-C snúra fylgir ekki með).
Tengdu RJ45 stjórnborðstengi tækisins við tölvuna þína með stjórnborðssnúrunni eins og eftirfarandi mynd sýnir.
22 Tenging
Mynd 3-3
Að tengja stjórnborðið (RJ45) tengi
Ómada C.ampus Stackable L3 Managed Switch
Tengdu Type-C stjórnborðstengi tækisins við tölvuna þína með Type-C snúru (fylgir ekki með) eins og eftirfarandi mynd sýnir.
Mynd 3-4
Að tengja stjórnborðið (USB) tengið
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Staðfestu uppsetningu
Eftir að uppsetningunni er lokið skaltu staðfesta eftirfarandi atriði: Það ætti að vera 5 til 10 cm bil í kringum tækið fyrir loftræstingu og vertu viss um að loftflæðið
er fullnægjandi. The voltage af aflgjafanum uppfyllir kröfuna um inntak voltage tækisins. Rafmagnsinnstungan, tækið og rekki eru vel jarðtengd. Tækið er rétt tengt öðrum nettækjum.
Tenging 23
Ómada C.ampus Stackable L3 Managed Switch
3.5 Kveikt
Stingdu kventengi meðfylgjandi rafmagnssnúru í rafmagnsinnstunguna á tækinu og settu jákvæða tengið í rafmagnsinnstungu eins og eftirfarandi mynd sýnir. Gakktu úr skugga um að voltage af aflgjafanum uppfyllir kröfuna um inntak voltage (100-240 V~ 50/60 Hz).
Mynd 3-5
Tengist við aflgjafa
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 Frumstilling
Eftir að kveikt er á tækinu byrjar það sjálfsprófun við sjálfkrafa. Röð prófa keyrir sjálfkrafa til að tryggja að tækið virki rétt. Á þessum tíma munu LED vísar þess svara í eftirfarandi röð:
1. PWR LED vísirinn logar stöðugt. SYS LED og LED vísar allra hafna halda áfram.
2. Eftir um það bil eina mínútu munu SYS LED og LED vísar allra tenginna blikka í augnablik og slokkna síðan.
3. Nokkrum sekúndum síðar mun SYS LED vísirinn blikka, sem táknar farsæla frumstillingu.
3.7 Stakkafræði
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Skipta
Samhæfðar gerðir
Magn
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
24 Tenging
Ómada C.ampus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Það eru þrjár staðfræðibyggingar fyrir mismunandi aðstæður, vinsamlegast byggðu rétta staðfræði í samræmi við þarfir þínar:
1. Gróðurfræði keðju: Gróðurfræði keðju er tiltölulega einföld og krefst ekki kapaltengingar á milli fyrstu og síðustu einingarinnar. Það er hentugur fyrir langlínu stöflun, en áreiðanleiki þess er tiltölulega lítill.
Mynd 3-6
Topology keðju
Staflahöfn hópur 2
Staflahöfn hópur 1
…
2. Hringsvæðifræði: Hringsvæðifræði hefur meiri áreiðanleika samanborið við keðjusvæðifræði. Þegar ein af keðjunum í hringafræðinni er aftengd, verður hringsvæðið að keðjusvæðifræði, en allt staflakerfið getur samt virkað eðlilega. Yfirbygging hringlaga krefst kapaltengingar á milli fyrstu og síðustu einingarinnar, þannig að hún hentar ekki fyrir langlínusafla.
Mynd 3-7
Hringfræði
Staflahöfn hópur 2
Staflahöfn hópur 1
…
Tenging 25
Ómada C.ampus Stackable L3 Managed Switch
3. Star Topology: Star Topology tengir rofana við miðlægan aðalrofa, þess vegna getur það aukið gagnaframsendingarhraðann verulega á milli meðlima rofa á sama tíma og það veitir sameinaða stjórnun.
Mynd 3-8
Stjörnusérfræði
Staflahöfn hópur 2
Staflahöfn hópur 3
Staflahöfn hópur 1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
26 Tenging
Ómada C.ampus Stackable L3 Managed Switch
Kafli 4 Stillingar
4.1 Stillingu lokiðview
Rofinn styður tvo stillingar valkosti:
Sjálfstæður hamur: Stilltu og stjórnaðu rofanum einn. Stjórnunarstilling: Stilltu og stjórnaðu nettækjunum miðlægt. Það er mælt með því í
netkerfi í stórum stíl, sem samanstendur af fjöldatækjum eins og aðgangsstaði, rofa og gáttum.
Athugið: Þegar rofanum er breytt úr sjálfstæðri stillingu í stjórnunarstillingu tapast stillingar rofans. Nánari upplýsingar er að finna í tengdum skjölum í niðurhalsmiðstöð embættismannsins websíða: https://support.omadanetworks.com/product/.
4.2 Sjálfstæð ham
Í sjálfstæðri stillingu, notaðu tölvu til að stilla og stjórna rofanum með því að nota GUI (grafískt notendaviðmót) eða CLI (skipanalínuviðmót).
Mynd 4-1
Topology fyrir sjálfstæða stillingu
Skipta
PC
Að nota GUI
1. Til að fá aðgang að stjórnunarsíðu rofans skaltu ganga úr skugga um að rofi og tölva séu í sama undirneti. Opnaðu vafra og sláðu inn IP-tölu rofans í veffangið og ýttu síðan á Enter takkann.
Ef rofinn fær IP-tölu frá DHCP-þjóninum (venjulega gátt) skaltu finna IP-tölu rofans á DHCP-þjóninum.
Ef ekki, notaðu sjálfgefna IP tölu 192.168.0.1 til að ræsa stjórnunarsíðu rofans.
2. Þegar þú skráir þig inn í fyrsta skipti skaltu stilla notandanafn og lykilorð til að vernda netið þitt og tæki betur. Eftir það mun kerfið sjálfkrafa beina þér aftur á innskráningarviðmótið til að auðkenna þig með nýstofnuðum innskráningarupplýsingum.
3. Eftir að innskráning tókst birtist aðalsíðan. Þú getur smellt á valmyndirnar efst og vinstra megin til að stilla samsvarandi aðgerðir.
Nánari stillingar er að finna í notendahandbókinni og CLI handbókinni. Leiðbeiningarnar er að finna í niðurhalsmiðstöð embættismannsins websíða: https://support.omadanetworks.com/product/.
Notkun CLI Settu upp Telnet eða SSH tengingu til að fá aðgang að rofanum í gegnum CLI.
Stillingar 27
Ómada C.ampus Stackable L3 Managed Switch
Notaðu stjórnborðstengi til að fá aðgang að rofanum. Þegar þú notar stjórnborðstengi skaltu ræsa flugstöðvahermiforritið (eins og Hyper Terminal) á tölvunni og stilla flugstöðvarhermiforritið á eftirfarandi hátt:
Baud hraði 38400 bps
Gagnabitar 8
Jöfnuður Enginn
Stöðvunarbitar 1
Flæðisstýring Engin
Nánari stillingar er að finna í notendahandbókinni og CLI handbókinni. Leiðbeiningarnar er að finna í niðurhalsmiðstöð embættismannsins websíða: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Stýristilling
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
Mynd 4-2
Manage the network via Omada Pro Hardware Controller (C5300)
Gáttarrofi
Omada Pro Hardware Controller (C5300) EAP
28 Stillingar
EAP
EAP
Viðskiptavinir
Ómada C.ampus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Finndu IP-tölu gáttarinnar. Opnaðu skipanalínuna á tölvunni þinni og sláðu inn ipconfig. Í niðurstöðulistanum skaltu finna sjálfgefna gáttina, sem er einnig IP-tala gáttarinnar.
2. Ræstu a web vafrann og sláðu inn IP-tölu gáttarinnar. Skráðu þig inn á gáttina web síðu. Farðu síðan í Network > LAN > DHCP Client List til að finna IP tölu stjórnandans í samræmi við MAC vistfang hans.
3. Sláðu inn IP tölu stjórnandans í veffangastikunni til að opna hana web síðu.
4. Á Omada Pro stjórntækinu web síðu, fylgdu töframanninum til að klára hraðuppsetninguna.
5. Eftir skjótan uppsetning birtist innskráningarsíðan. Sláðu inn notandanafn og lykilorð sem þú hefur búið til og smelltu á Innskráning. Síðan geturðu stillt stjórnandann frekar.
6. Ef þú vilt stjórna tækjunum fjarstýrt skaltu fylgja næstu skrefum:
a. Gakktu úr skugga um að Cloud Access sé virkt á stjórnandi þínum. Sjálfgefið er að Cloud Access er virkt. Gakktu úr skugga um að Cloud LED blikkar hægt.
b. Ræstu a web vafra og sláðu inn https://omada.tplinkcloud.com í veffangastikuna. Sláðu inn TP-Link auðkenni og lykilorð til að skrá þig inn. Smelltu á + Bæta við stjórnanda og veldu Vélbúnaðarstýringu til að bæta við stjórnandanum þínum. Þá geturðu stillt stjórnandann frekar.
For more details, refer to the Installation Guide of C5300.
Með Omada Pro hugbúnaðarstýringu
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
Mynd 4-3
Stjórnaðu netinu í gegnum Omada Pro Software Controller
Gátt
Skipta
Stjórnandi
Omada Pro hugbúnaðarstýringaraðgangspunkt
AP
AP
keyrandi á gestgjafatölvunni
Viðskiptavinir
Stillingar 29
Ómada C.ampus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web síðu. Ef ekki, smelltu á Ræsa vafra til að stjórna netinu.
2. Á Omada Pro stjórntækinu web síðu, fylgdu töframanninum til að klára hraðuppsetninguna.
3. Eftir skjótan uppsetning birtist innskráningarsíðan. Sláðu inn notandanafn og lykilorð sem þú hefur búið til og smelltu á Innskráning. Síðan geturðu stillt stjórnandann frekar.
4. Ef þú vilt stjórna tækjunum fjarstýrt skaltu fylgja næstu skrefum:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web síðu, farðu í Stillingar > Cloud Access til að virkja Cloud Access og binda TP-Link auðkennið þitt. Ef þú hefur sett það upp í flýtiuppsetningu skaltu sleppa þessu skrefi.
b. Ræstu a web vafra og sláðu inn https://omada.tplinkcloud.com í veffangastikuna. Sláðu inn TP-Link auðkenni og lykilorð til að skrá þig inn. Listi yfir stýringar sem hafa verið bundnir við TP-Link auðkenni þitt mun birtast. Síðan geturðu smellt á Ræsa til að stilla stjórnandann frekar.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Með Omada Pro skýjatengdum stjórnanda
Omada Pro Cloud-Based Controller er góður valkostur án þess að þurfa að setja upp hugbúnaðarstýringuna á tölvu.
Leyfi þarf að kaupa til viðbótar.
Mynd 4-4
Stjórnaðu netinu í gegnum Omada Pro Cloud-Based Controller
Omada ský
Gátt
Skipta
AP
AP
AP
AP
Viðskiptavinir
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web vafranum og sláðu inn https://omada.tplinkcloud.com í veffangastikuna. Skráðu þig inn með
your TP-Link ID.
30 Stillingar
Ómada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Þú getur ræst stjórnandann til að taka upp og stjórna tækjum. * Omada appið Með Omada appinu geturðu einnig stjórnað stjórnandanum þínum á staðnum eða á fjarlægum stað í gegnum snjalltækið þitt. Nánari upplýsingar um stillingar er að finna í notendahandbók stjórnandans. Handbókina er að finna í niðurhalsmiðstöð opinberu vefsíðunnar okkar. websíða: https://support.omadanetworks.com/product/.
Stillingar 31
Ómada C.ampus Stackable L3 Managed Switch
Viðauki A Úrræðaleit
Q1. Hvað gæti ég gert ef ég gleymdi notendanafni og lykilorði rofans?
1. Tengdu stjórnborðstengi tölvunnar við stjórnborðstengi rofans og opnaðu flugstöðvahermiforrit.
2. Slökktu á og endurræstu rofann. Framkvæmdu aðgerðina sem flugstöðvarhermiforritið gefur til kynna til að komast í bootUtil valmyndina. Aðgerðin er mismunandi eftir vöru. Mögulegar aðgerðir eru taldar upp hér að neðan: · Ýttu á hvaða takka sem er til að stöðva sjálfvirka ræsingu. · Ýttu á CTRL-B til að komast í bootUtil valmyndina.
3. bootUtil valmyndin birtist. Sláðu inn töluna 6 til að velja valkostinn „Password recovery“ og sláðu inn Y til að eyða öllum notendum og lykilorðum. Þá geturðu endurstillt notandanafnið og lykilorðið.
Spurning 2. Hvers vegna virkar PWR LED ljósið óeðlilega? PWR/Power LED ljósið ætti að lýsa upp þegar rafkerfið virkar eðlilega. Ef PWR/Power LED ljósið virkar óeðlilega skaltu gera eftirfarandi:
1. Gakktu úr skugga um að rafmagnssnúran sé rétt tengd og að rafmagnstengið sé eðlilegt. 2. Gakktu úr skugga um að hljóðstyrkurinntage af aflgjafanum uppfyllir kröfuna um inntak voltage af
skipta.
Q3. Hvað á ég að gera ef ég kemst ekki í web stjórnunarsíða? Prófaðu eftirfarandi:
1. Athugaðu hvert ljósdíóða tengisins á rofanum og vertu viss um að Ethernet snúran sé rétt tengd. 2. Prófaðu annað tengi á rofanum og vertu viss um að Ethernet snúran henti og virki eðlilega. 3. Slökktu á rofanum og kveiktu á honum aftur eftir smá stund. 4. Gakktu úr skugga um að IP-tala tölvunnar þinnar sé stillt innan undirnets rofans. 5. Ef þú hefur enn ekki aðgang að stillingarsíðunni skaltu endurstilla rofann á sjálfgefnar verksmiðjustillingar. Þá
IP tölu tölvunnar þinnar ætti að vera stillt sem 192.168.0.x ("x" er hvaða tala sem er frá 2 til 254) og undirnetmaska sem 255.255.255.0.
Spurning 4. Af hverju birtist hermunarforritið fyrir flugstöðina ekki rétt? Prófaðu eftirfarandi:
1. Gakktu úr skugga um að aflgjafinn sé eðlilegur og að stjórnborðssnúran sé rétt tengd. 2. Athugaðu hvort stjórnborðssnúran sé af réttri gerð. 3. Gakktu úr skugga um að færibreytur flugstöðvarhermiforritsins séu réttar: stilltu bita á sekúndu
sem 38400, Gagnabitar sem 8, Jöfnuður sem Engir, Stöðvunarbitar sem 1 og flæðisstýring sem Enginn.
32 Viðauki A Úrræðaleit
Ómada C.ampus Stackable L3 Managed Switch
Viðauki B Forskriftir
Specifications for S6500 Series Switches
Atriði
Efni
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Staðlar
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
Viðauki B Upplýsingar 33
Ómada C.ampus Stackable L3 Managed Switch
PoE fjárhagsáætlun
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Rekstrarhitastig og hæð
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Geymsluhitastig -40 °C til 70 °C (-40 °F til 158 °F)
Raki 10% til 90% RH Óþéttandi
Geymsla Raki
5% til 90% RH Óþéttandi
34 Viðauki B Upplýsingar
Ómada C.ampus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Atriði
Efni
Staðlar
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
LED
Rekstrarhitastig og hæð
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Geymsluhitastig -40 °C til 70 °C (-40 °F til 158 °F)
Raki 10% til 90% RH Óþéttandi
Geymsla Raki
5% til 90% RH Óþéttandi
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Stuðningshæðin er frá sjávarmáli upp í 5000 m. Athuga skal að þegar hæðin er yfir 2000 m, þá lækkar hámarksrekstrarhitastigið um 220°C (1°F) fyrir hverja 1.8 metra hækkun.
Viðauki B Upplýsingar 35
Ómada C.ampus Stackable L3 Managed Switch
Tæknilýsing fyrir aflgjafaeiningar
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Power Input
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
Output Voltage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
Úttaksstraumur
9.35 A (hámark)
16.5 A (hámark)
45 A (hámark)
Output Power
500 W (hámark)
900 W (hámark)
550 W (hámark)
Rekstrarhæð
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 Viðauki B Upplýsingar
CE-merki viðvörun
Þetta er vara í flokki A. Í heimilisumhverfi getur þessi vara valdið útvarpstruflunum, í því tilviki gæti notandinn þurft að gera fullnægjandi ráðstafanir.
Samræmisyfirlýsing ESB
TP-Link lýsir því hér með yfir að rofinn sé í samræmi við grunnkröfur og aðrar viðeigandi ákvæði tilskipana 2014/30/ESB, 2014/35/ESB, 2011/65/ESB og (ESB) 2015/863. Upprunalegu samræmisyfirlýsingu ESB er að finna á https://www.tp-link.com/en/support/ce/
Samræmisyfirlýsing Bretlands
TP-Link lýsir því hér með yfir að rofinn sé í samræmi við grunnkröfur og aðrar viðeigandi ákvæði reglugerðar um rafsegulsamhæfi frá 2016 og reglugerðar um öryggi rafbúnaðar frá 2016. Upprunalegu samræmisyfirlýsinguna frá Bretlandi er að finna á https://www.tp-link.com/support/ukca/
, .
VARÚÐ:
Tvöfaldur stöng, hlutlaus bræðsla. Aftengdu rafmagn fyrir viðhald.
Öryggisupplýsingar
· Haltu tækinu frá vatni, eldi, raka eða heitu umhverfi. · Ekki reyna að taka í sundur, gera við eða breyta tækinu. Ef þú þarft þjónustu, vinsamlegast hafðu samband við okkur. · Settu tækið þannig að botnflöturinn vísi niður. · Innstungan á rafmagnssnúrunni er notuð sem aftengingarbúnaður, innstungan skal vera
Auðvelt aðgengi. · Stingdu vörunni í jarðtengda innstungu í gegnum rafmagnssnúruna.
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
rafhlöður.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Vinsamlegast lestu og fylgdu ofangreindum öryggisupplýsingum þegar þú notar tækið. Við getum ekki ábyrgst að engin slys eða skemmdir eigi sér stað vegna óviðeigandi notkunar á tækinu. Vinsamlegast notaðu þessa vöru með varúð og notaðu hana á eigin ábyrgð.
Fyrir tæknilega aðstoð, notendahandbækur og aðrar upplýsingar, vinsamlegast farðu á https://support.omadanetworks.com/ eða skannaðu einfaldlega QR kóðann.