  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • Ef leiðbeiningum í þessari handbók er ekki fylgt getur það skemmt kerfisíhluti, stofnað starfsfólki í hættu, skemmdir á eignum eða ógilda ábyrgð á spjaldinu.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

ALMENNAR KRÖFUR

  • Vinsamlegast lestu þessa handbók í heild sinni fyrir uppsetningu.
  • Tilgangur þessa skjals er að veita lágmarkskröfur og ráðleggingar um örugga og árangursríka uppsetningu á SoliTek PV einingum.
  • Þetta skjal inniheldur einnig kröfur sem eru nauðsynlegar til að halda SoliTek PV eining í samræmi við IEC 61215, IEC 61730, UL 61730 staðla.
  • Þessi leiðarvísir inniheldur grunnupplýsingar um JSC „SoliTek Cells“ SOLID röð ljósolíueiningar, uppsetningu þeirra og örugga meðhöndlun. Lesa skal og skilja allar leiðbeiningar áður en reynt er að setja upp. Ef það eru einhverjar spurningar, vinsamlegast hafðu samband við söluaðila þinn eða JSC "SoliTek Cells" til að fá frekari upplýsingar.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • Brot á eða ónákvæmt fylgni við ákvæði þessara skjala ógildir ábyrgðina.
  • Uppsetningaraðilinn verður að skilja og fylgja öllum viðeigandi staðbundnum, ríkjum og alríkisreglum og stöðlum um byggingu byggingar, rafhönnun, bruna og öryggi, og verður að hafa samband við staðbundin yfirvöld til að ákvarða viðeigandi leyfiskröfur áður en reynt er að setja upp eða viðhalda PV einingar og ætti kynnast vélrænum og rafmagnskröfum fyrir ljósvakakerfi.
  • Ef ekki er farið eftir leiðbeiningum í þessari handbók getur það skemmt kerfisíhluti, stofnað starfsfólki í hættu, skemmdir á eignum eða ógilda ábyrgð á spjaldinu.
  • Þak PV kerfi ætti aðeins að vera sett upp á híbýlum sem hafa verið formlega greind með tilliti til byggingarheilleika og staðfest að vera fær um að meðhöndla aukið vegið álag á PV kerfishluta, þ.mt PV einingar, af löggiltum byggingarsérfræðingi eða verkfræðingi.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • Flatplata PV mátbyggingin samanstendur af lagskiptri samsetningu sólarsella sem eru hjúpuð í einangrunarefni í tveimur glerplötum.
  • Geymið þessi skjöl á öruggum stað til að vísa í síðar.
  • Ekki reyna að taka eininguna í sundur og ekki fjarlægja áföst nafnplötur eða íhluti! Með því að gera það fellur ábyrgðin úr gildi.

Meðhöndlun & Umsókn

MEÐHÖNDUN

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • Ekki fara yfir hámarkshæð bretta sem á að stafla, eins og tilgreint er á brettaumbúðunum.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

UMSÓKN

Takmarkanir

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • Tilbúnu einbeitt ljós má ekki beina að SoliTek PV einingar.

Meðmæli

  • SoliTek mælir með því að PV einingar séu settar upp í að minnsta kosti 10 gráðu hallahorni til að leyfa rétta sjálfhreinsun frá rigningu.
  • Skygging að hluta eða algjörlega á PV einingu eða einingum getur dregið verulega úr afköstum kerfisins.
  • SoliTek mælir með því að lágmarka magn skugga allt árið til að auka orkumagnið sem framleitt er af PV einingunum.
  • High system voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage bylgjur.
  • Betri loftræsting eininga og styttri tengikaplar auka raforkuframleiðslu.

Fyrir tvíhliða einingar:

  • Mælt er með því að auka hæð PV spjaldsins frá jörðu þannig að meira ljós geti borist undir eininguna og síðan endurspeglað
  • Tvíhliða ávinningurinn eykst verulega ef einingar eru settar upp fyrir ofan hvíta (hátt albedo gildi), ljósendurkastandi yfirborð.

Rafmagnsuppsetning

ÖRYGGI

  • PV einingar geta framleitt straum og voltage þegar það verður fyrir ljósi af hvaða styrkleika sem er. Rafstraumur eykst með meiri ljósstyrk. DC binditage af 50 voltum eða hærra er hugsanlega banvænt. Snerting við straumrás ljósvakakerfis sem starfar undir ljósi getur valdið banvænu raflosti.
  • Rafmagnaðu PV einingar með því að fjarlægja þær algjörlega úr ljósi eða með því að hylja framflöt þeirra með ógegnsæju efni. Varðandi öryggisreglur fyrir rafbúnað í spennu þegar unnið er með einingar sem verða fyrir hvaða ljósi sem er. Notaðu einangruð verkfæri og notaðu ekki málmskartgripi þegar þú vinnur með PV einingar.
  • Til að forðast ljósboga og raflost skaltu ekki aftengja rafmagnstengingar undir álagi. Gallaðar tengingar geta einnig valdið ljósboga og raflosti. Haltu tengjum þurrum og hreinum og tryggðu að þau séu í réttu vinnuástandi. Settu aldrei málmhluti í tengin eða breyttu þeim á nokkurn hátt til að tryggja rafmagnstengingu.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • Uppsetning sólarljóskerfa krefst sérhæfðrar færni og þekkingar. Það ætti aðeins að framkvæma af hæfu og sérþjálfuðu starfsfólki. Uppsetningaraðili tekur á sig alla hættu á meiðslum, þar með talið hættu á raflosti.
  • Notaðu aðeins búnað, tengi, raflögn og festingarbúnað sem er sérstaklega hannaður til notkunar í ljósakerfi.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • Þegar þú aftengir víra sem eru tengdir við ljóseindaeiningu sem verður fyrir ljósi getur myndast rafbogi. Bogar geta valdið bruna, kveikt eld eða á annan hátt skapað öryggisvandamál (allt að banvænu raflosti).
  • Athugaðu hvort eftir binditage before starting and observe the local safety-relevant regulations for such working conditions.
  • Við venjulegar aðstæður getur ljóseindaeining framleitt meiri straum og/eða rúmmáltage (hér: 30V DC) en greint er frá við staðlaðar prófunaraðstæður.
  • Snerting við DC voltage af 30 V eða meira er hugsanlega hættulegt. Gæta skal varúðar við raflögn eða meðhöndlun einingar sem verða fyrir sólarljósi.
  • Tengdu aðeins einingar með sama úttaksstraumi í röð. Ef einingar eru tengdar í röð er heildarmagntage er jafnt summu einstakra eininga binditages.
  • Tengdu aðeins einingar eða raðsamsetningar eininga með sama rúmmálitage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • Notaðu alltaf sömu gerð eininga innan tiltekins ljóskerfa.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • Notaðu viðeigandi öryggisbúnað (einangruð verkfæri, rafmagnshanska, skó o.s.frv.) sem er samþykktur til notkunar á raforkuvirkjum.

SAMSETNING

  • Við venjulegar aðstæður er líklegt að ljósvökvaeining muni upplifa aðstæður sem framleiða meiri straum og/eða rúmmáltage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) ætti að margfalda með stuðlinum allt að 1.25 miðað við lægsta og hæsta umhverfishita sem skráð er fyrir uppsetningarstaðinn þegar magn íhluta er ákvarðaðtage einkunnir, leiðara straum einkunnir, öryggi stærðir, og stærð stjórna tengdum PV úttak.
  • Voltages eru aukefni þegar PV einingar eru tengdar beint í röð og einingarstraumar eru aukefni þegar PV einingar eru tengdar beint samhliða. PV einingar með mismunandi rafmagnseiginleika má ekki vera tengdar beint í röð. Notkun viðeigandi rafeindatækja frá þriðja aðila sem tengd eru PV-einingum getur gert mismunandi raftengingar kleift og verður að vera sett upp í samræmi við tilgreindar leiðbeiningar framleiðanda.
  • Hámarks voltage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Einnig er hámarksinntaksvoltagTaka verður tillit til e af inverterinu og öðrum raftækjum í kerfinu. The open circuit voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

Yfirstraumsvarnartæki (OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • Öryggi amp einkunn ≥ 1.25 x Isc
  • Veldu næsta hærri staðaleinkunn í vörulistanum yfir tiltæka PV öryggi.
  • Isc = Skammhlaupsstraumur einnar einingar við staðlaðar prófunarskilyrði (STC).
  • Miðað við gildi Isc of SoliTek eininga er rétt gildi PV öryggi sem nota á við uppsetningu 30 A. SoliTek mælir með því að nota PV öryggi í bæði jákvæðu og neikvæðu leiðarana.

KARNAR OG LAGNIR

SoliTek PV einingar eru með tveimur stöðluðum, sólarljósþolnum úttakssnúrum sem eru endaðir með PV tengjum sem eru tilbúnar fyrir flestar uppsetningar. Jákvæð (+) tengi er með karltengi á meðan neikvæða (-) tengi er með kventengi. Einingin er ætluð fyrir raðtengingar (þ.e. karl (+) til kvenkyns (-) samtengingar) en er einnig hægt að nota til að tengja viðeigandi rafmagnstæki frá þriðja aðila sem kunna að hafa aðrar raflagnastillingar svo framarlega sem leiðbeiningum framleiðanda er fylgt.
Notaðu raflagnir á vettvangi með viðeigandi þversniðssvæðum sem eru samþykktar til notkunar við hámarks skammhlaupsstraum PV einingarinnar. Allar raflögn verða að vera tvöfalt einangruð, krosstengd snúrur með lágmarksstyrkleika 1,8 kV (yfir 1500 V vol.tage) og lágmarkshiti 90 ˚C (190 °F). Vírstærð ekki minni en 4 mm² (12 AWG). Gerð einangrunar ætti að vera viðeigandi fyrir þá gerð uppsetningaraðferðar sem notuð er og verður að uppfylla kröfur IEC 61730 og öryggisflokks II.

  • Einangrunarstig: 1,8 kV (leiðari-leiðari).
  • Hitastig: -40°C upp í +90°C (-40°F allt að 190°F) að minnsta kosti.
  • Uppbygging leiðara: tindaður þráður koparvír með koparhreinleika meiri en 99,9%.
  • Aðaleinangrun: krossbundið pólýetýlen (XLPE), sólarljós og rakaþolið, logavarnarefni. Hentar fyrir rásir og kappakstursbrautir neðanjarðar.
  • Einangrun (jakki): hitaþolinn, sólarljósþolinn, logavarnarefni, vatnsheldur.
  • Lágmarks ytra þvermál kapals með einangrun – 5,2 mm (2,05 tommur).
  • Lágmarks þversnið leiðara – 4 mm² (12 AWG).

SoliTek mælir með því að uppsetningaraðilar noti aðeins sólarljósþolnar snúrur sem eru hæfir fyrir jafnstraumslögn (DC) í PV kerfum. Kaplar ættu að vera festir við festingarbygginguna á þann hátt að forðast megi vélræna skemmdir á kapalnum og/eða einingunni. Ekki leggja álag á snúrurnar. Til að festa, notaðu viðeigandi úrræði, svo sem sólarljósþolin snúrubönd og/eða vírastjórnunarklemmur. Þó að snúrurnar séu sólarljóssþolnar og vatnsheldar, þar sem hægt er, skal forðast beina útsetningu fyrir sólarljósi og vatnsdýfa í snúrunum.
Stöðluð lengd kapla frá tengiboxum er 1,2 m (47,24 tommur). Stefnt er að því að tvö spjöld myndu samtengjast í kerfinu.

JÖRÐUN

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
Göt merkt með jarðtengingarmerki á grindinni má aðeins nota til jarðtengingar. Ekki bora fleiri jarðtengingargöt á ramma einingarinnar.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Jarðleiðari verður þá að tengja við jörð með því að nota viðeigandi jarðrafskaut.
A bolted connection is required; it incorporates:

  • Boltastærð M4.
  • Tannþvottavél undir boltahausnum eða tönnuð bolt verður að komast í gegnum óleiðandi húðun eins og anodized ramma.
  • Festu hneta sem hentar fyrir M4 bolta.
  • Allur vélbúnaður skal vera úr járnlausum málmi, 300-röð ryðfríu stáli eða tæringarvarinn með viðeigandi hætti.
  • Ráðlagt tog til að læsa hnetunni er 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
  • Jarðbolti þarf að fara í gegnum alla tengihluti.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • Tæki sem eru skráð og auðkennd til að jarðtengja málmgrind PV-eininga eru leyfð til að jarðtengja óvarða málmgrind einingarinnar við jarðtengd uppsetningarvirki.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

TENGI

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • Ekki reyna að tengja rafmagn með blautum, óhreinum eða öðrum gölluðum tengjum.
  • Forðastu útsetningu fyrir sólarljósi og vatnsdýfu í tengjunum. Forðist tengi sem hvíli á jörðu eða þakfleti.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • Athugaðu hvort allar raftengingar séu tryggilega festar. Gakktu úr skugga um að öll læsatengi séu að fullu tengd og læst.

HJÁRÁÐARDÍÓÐUR

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Bypass díóður eru ekki yfirstraumsvörn. Hjáveitu díóða beina straumi frá frumustrengjum ef skygging er að hluta. Eiginleikar þessara díóða:

  • VoltagE einkunn – 50 V.
  • Núverandi einkunn – 25 A.

SLÁNAFLOKKUR

  • SoliTek SOLID Bifacial og Blackstar einingar hafa verið samþykktar í IEC brunaprófun og uppfylla eldfimiflokk A. Brunaprófun var framkvæmd við 127 mm (5 tommu) halla á hverja 300 mm (11,81 tommu), eins og kveðið er á um í lið A.2.5 í IEC 61730-2.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

Vélræn festing

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

ALMENNAR KRÖFUR

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • Vinsamlega fylgdu öryggisreglum og uppsetningarleiðbeiningum sem fylgja með festingarkerfinu. Ef nauðsyn krefur, vinsamlegast hafðu beint samband við birginn til að fá frekari upplýsingar.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • Gakktu úr skugga um að festingarstöngin muni ekki afmyndast eða hafa áhrif á einingarnar þegar hún stækkar vegna hitauppstreymis.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • Ekki reyna að bora göt í glerflötinn og ramma eininganna þar sem það fellur úr gildi ábyrgðina.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

Festingarhlutirnir verða að vera úr endingargóðu, ætandi og UV-þolnu efni (mælt er með ryðfríu stáli og anodized álhlutum).

FESTING MEÐ CLAMPS

  • Notaðu að minnsta kosti 4 lagskipt clamps til að festa einingar á festingarteinum. Einingar clampMálmhlutir ættu ekki að komast í snertingu við fram- eða bakglerið. Þegar þú velur þessa tegund af clamp-festingaraðferð, notaðu að minnsta kosti fjóra clamps á hverri einingu; tveir clamps ætti að vera fest á hvorri langhlið. Það fer eftir staðbundnum vindi og snjóþunga, viðbótarklamps gæti verið krafist til að tryggja að einingar geti borið álagið.
  • Clamps aðdráttarvægi ætti að vera að minnsta kosti 15 Nm (11,06 ft-lb), en ekki meira en 20 Nm (14,75 ft-lb). Venjulega næst 15 Nm (11,06 ft-lb) þegar tveir ál profiles snerta hvert annað. Þegar eining er sett upp í andlitsstöðu á hallaþakinu sem hefur >45° halla, þarf viðbótarkrók í botn einingarinnar.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

Með þverstæðum teinum

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • Þegar þú velur þessa tegund af clamp-festingaraðferð, notaðu að minnsta kosti fjóra clamps á hverri einingu; tveir clamps ætti að vera fest á hvorri hlið einingarinnar. Einingar clamps ætti ekki að komast í snertingu við framglerið og má ekki afmynda rammann.
  • Vertu viss um að forðast skuggaáhrif á sólarsellur frá einingunni clamps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • Lengd clamp should be at least 30 mm (1,18 inch).
  • Klamp verður að skarast einingarrammann um að minnsta kosti 5 mm (0,2 tommu), en ekki meira en 10 mm (0,4 tommu).

Með þverstæðum teinum

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

Án þverlaga teina eða teinar eru hornrétt á langhliðarrammann

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

Með innsetningarkerfi

SoliTek-SOLID-Series-Solar-Modules-FIG-12

Festing með boltum

  • Einingin verður að vera fest og studd með fjórum M8 ryðfríu stáli boltum í gegnum tilgreind festingargöt á þverstöngunum. Tog á clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampvelja þarf vélbúnað.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • Bannað er að bora nýjar holur og ógilda ábyrgðina.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

STAÐA SAMSLUTNINGARSINS

  • Fyrir fjarlægðina milli tengikassa og brúnar einingarinnar eða aðrar stærðir á stöðu tengikassa og svæði, vinsamlegast skoðaðu myndirnar hér að neðan.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

VIÐHALD

  • Til að tryggja hámarksafköst eininga mælir SoliTek með eftirfarandi:
  • Ef nauðsyn krefur er hægt að þrífa glerframhlið einingarinnar með vatni og mjúkum svampi eða klút.
  • Nota má milt þvottaefni sem ekki er slípiefni til að fjarlægja þrjóskari bletti.
  • Athugaðu rafmagns- og vélrænni tengingar reglulega og vertu viss um að þær séu hreinar, öruggar, heilar og öruggar.
  • Ef upp koma vandamál, hafðu samband við viðurkenndan/hæfan aðila.

LEIÐBEININGAR

Parameter \ Fyrirmynd BLACKSTAR B.96 SOLID Black (Semi-Clear) B.96 35(40) mm BLACKSTAR Satin B.96 MAGNUS B.108
Prófskilyrði STC STC STC STC
Nafnvald 455 W 455 W 445 W 510 W
Rafmagnsgögn @STC
Hámarksafl (Pmax), W 455 455 445 510
Voltage við hámarksafl (Vmpp), V 29,71 29,71 29,40 33,34
Núverandi við hámarksafl (Impp), A 15,31 15,31 15,14 15,30
Open Circuit Voltage (Voc), V 34,82 34,82 34,40 39,06
Skammhlaupsstraumur (Isc), A 15,97 15,97 15,79 15,95
Hitaupplýsingar
Rekstrarhitasvið -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Hitastuðull Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F)
Hitastuðull Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F)
Hitastuðull Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F)
Gögn um stærð og þyngd
Lengd 1762 mm 1762 mm 1762 mm 1961 mm
Breidd 1134 mm 1134 mm 1134 mm 1134 mm
Þykkt 30 mm 35(40) mm 30 mm 30 mm
Þyngd 25,5 kg 35(36) kg 25,5 kg 28,5 kg
Uppsetningaraðferð
Reference to the chapter 3.3 3.3 3.3 3.3
Annað
Hámarks bakstraumur, A 30
Fire    class, IEC 61730/UL 61730 A/gerð II
Hámarks kerfi binditage, V 1500

Table 9. Electrical and mechanical parameters table.

Parameter \ Fyrirmynd FAST Semi- clear B.96 SOLID Black B.96 FAST Satin B.96 FAST Agro B.64
Prófskilyrði STC STC STC STC
Nafnvald 455 W 455 W 445 W 300 W
Rafmagnsgögn @STC
Hámarksafl (Pmax), W 455 455 445 300
Voltage við hámarksafl (Vmpp), V 29,71 29,71 29,40 19,60
Núverandi við hámarksafl (Impp), A 15,31 15,31 15,14 15,31
Open Circuit Voltage (Voc), V 34,82 34,82 34,40 22,76
Skammhlaupsstraumur (Isc), A 15,97 15,97 15,79 15,97
Hitaupplýsingar
Rekstrarhitasvið -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Hitastuðull Pmax -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Hitastuðull Voc -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Hitastuðull Isc +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Gögn um stærð og þyngd
Lengd 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
Breidd 1144±2 1144±2 1144 ± 2 mm 1144 ± 2 mm
Þykkt 7,2 mm 7,2 mm 7,2 mm 7,2 mm
Þyngd 33 kg 33 kg 33 kg 33 kg
Uppsetningaraðferð
Reference to the chapter 3.2 3.2 3.2 3.2
Annað
Hámarks bakstraumur, A 30
Fire    class, IEC 61730/UL 61730 A/gerð II
Hámarks kerfi binditage, V 1500

Table 10. Electrical and mechanical parameters table.

Parameter \ Fyrirmynd SOLID Satin B.96 35 mm SOLID Satin B. 96 40 mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
Prófskilyrði STC STC STC STC
Nafnvald 445 W 445 W 300 W 300 W
Rafmagnsgögn @STC
Hámarksafl (Pmax), W 445 445 300 300
Voltage við hámarksafl (Vmpp), V 29,40 29,40 19,60 19,60
Núverandi við hámarksafl (Impp), A 15,14 15,14 15,31 15,31
Open Circuit Voltage (Voc), V 34,40 34,40 22,78 22,78
Skammhlaupsstraumur (Isc), A 15,79 15,79 15,97 15,97
Hitaupplýsingar
Rekstrarhitasvið -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Hitastuðull Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Hitastuðull Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Hitastuðull Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Gögn um stærð og þyngd
Lengd 1762 mm 1762 mm 1762 mm 1762 mm
Breidd 1134 mm 1134 mm 1134 mm 1134 mm
Þykkt 35 mm 40 mm 35 mm 40 mm
Þyngd 35 kg 36 kg 35 kg 36 kg
Uppsetningaraðferð
Reference to the chapter 3.3
Annað
Hámarks bakstraumur, A 30
Fire    class, IEC 61730/UL 61730 A/gerð II
Hámarks kerfi binditage, V 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • Allar SoliTek SOLID PV spjöld samsvara rafmagnsöryggisflokki II.

Fyrirvari um ábyrgð

  • Þar sem það er ómögulegt fyrir SoliTek að stjórna uppsetningu, rekstri, beitingu og viðhaldi ljósvakakerfisins samkvæmt þessum leiðbeiningum. SoliTek tekur enga ábyrgð og afsalar sér beinlínis ábyrgð á tjóni, tjóni eða kostnaði sem stafar af eða tengist á einhvern hátt slíkri uppsetningu, rekstri, notkun eða viðhaldi.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

Algengar spurningar

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

Skjöl / auðlindir

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

Heimildir

Spyrðu spurningu

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Spyrðu spurningu

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.