Part Numbers: CSEN1-H-W-ZHA (white enclosure) and CSEN1-H-G-ZHA (gray enclosure)

LÝSING

The CSEN1 is a low voltage Networked Lighting Controller with an integrated passive infrared sensor and a photocell. It is powered via the AUX power from the LED driver. The CSEN1 autodetects both 0-10V Drivers and D4i Drivers to simplify the installation. The product is DLC certified for both indoor and outdoor applications.

LEIÐBEININGAR

  • Útvarpstíðni: 2.4 GHz (IEEE 802.15.4)
  • RF sendingarúttak: +20dBM
  • Notkunarhiti: -40° til +70° C
  • Raki í notkun: 10 til 95%, ekki þéttandi
  • IP66 metið girðing
  • Mál: 3.1" D x 1.6" H (80 mm D x 42 mm H)
  • Input Power: 12-24VDC, 35mA max, 840mW
  • Tilgangur eftirlits: Rekstur
  • Environmental: Indoor/Outdoor
  • Mengunarstig: 3
  • Metið Impulse Voltage: 330V

HÖNNUNARFRÆÐI

Below are some recommendations for successful analog dimming using the CSEN1. The analog dimming control wires are referenced as DALI+/DIM+ and Common Ground/DALI-. The dimming signals have a Maximum voltage af 10V DC.

  • Do not ground the Common Ground/DALI- wire to chassis ground; this is a return signal and is critical for proper dimming.
  • Beindu deyfingarvíra í burtu frá AC línum ef mögulegt er.
  • Að hámarki 4 DALI-2/D4i LED rekla á hvern stjórnanda, hafðu samband við Synapse Support ef þörf er á hærra hlutfalli.
  • Maximum of 8 DIM to OFF LED Drivers for DIM to OFF Designs.
  • Ekki festa á hitakassa eða á LED drif.

ATH: LED Driver verður að styðja DIM til OFF virkni.
VIÐVÖRUN OG VARÚÐ

  • TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING OR SERVICING!
  • The CSEN1 should only be installed in a fixture with a Zhaga Book 18 receptacle.
  • Misbrestur á að fylgja þessum leiðbeiningum og viðvörunum gæti hugsanlega ógilt ábyrgðina.
  • This product must be installed in accordance with national, state, and local electrical codes and requirements.
  • If you are unsure about any part of these instructions, consult an electrician; qualified personnel should perform all work.

UPPLÝSINGAR um raflögn UM ZHAGA BOOK 18 SOCET

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING OR SERVICING!
For fixtures with an existing Zhaga socket, prior to installation, verify the wiring per the details below. (See Figure 1) If the fixture does not have a Zhaga socket, use the appropriate Wired Adapter accessory based on the knockout size: CSEN1-ZHA-ADPT-22 for 22mm knockouts, or CSEN1-ZHA-ADPT-33 for 33mm knockouts. The specifications for the signal wires are:

  • 12-24VDC POWER: Brown
  • Common Ground/DALI-: Pink with White Stripe
  • DALI+/DIM+: Violet with White Stripe
  • Solid Conductor, 105°C, Rated for 600VAC, AWG 20, 15” Length

MYND 1 Synapse CSEN1 Combo Sensor Controller - FIGURE 1

UPPSETNINGSLEIÐBEININGAR

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING OR SERVICING!

  1. Ef við á skaltu fjarlægja lokunarhettuna eða ljósastýringarbúnaðinn sem nú er uppsettur í innréttingunni.
  2. Align the CSEN1 such that the contacts pins are positioned at the appropriate the receptacle contacts.
  3. After alignment, push until the CSEN1 is fully seated within the receptacle.
  4. While pushing against the device, twist the CSEN1 housing clockwise until it locks into place. The CSEN1 includes a latching key or notch that will lock into position with an audible “click”. (See Figure 2)

Athugið: Til að virka rétt skaltu ganga úr skugga um að stjórnandinn sé settur alveg í innstunguna og snúinn í læsta stöðu.
Viðvörun: The Zhaga receptacle should not turn during installation. Turning the receptacle could damage the internal fixture wiring by pulling it loose.
MYND 2Synapse CSEN1 Combo Sensor Controller - FIGURE 2

STATUS LED

Power LED Staða 
Blár On for 3 seconds at Startup, then Off
LED stöðu Staða 
Rauður No script on the device
Blikkandi Rautt Samskiptavilla
Blikkandi blátt Communication, No Config
Blikkandi grænt Normal Operation with Motion
Slökkt Normal Operation, no Motion

REGLUGERÐARUPPLÝSINGAR OG VOTTANIR
RF Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada (IC) vottorð: Þetta stafræna tæki fer ekki yfir B-flokksmörk fyrir útvarpshávaða frá stafrænum tækjum sem sett eru fram í útvarpstruflunum reglugerðum kanadíska samskiptaráðuneytisins.
FCC vottorð og reglugerðarupplýsingar (aðeins í Bandaríkjunum)
FCC Part 15 Class B: Þetta tæki er í samræmi við hluta 15 í FCC reglum. Notkun er háð eftirfarandi tveimur skilyrðum: (1) Þessi tæki mega ekki valda skaðlegum truflunum og (2) Þessi tæki verða að sætta sig við allar mótteknar truflanir, þar með talið truflanir sem geta valdið skaðlegri notkun.
RADIO FREQUENCY INTERFERENCE (RFI) (FCC 15.105): This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Re-orient or relocate the receiving antenna; (2) Increase the separation between the equipment and the receiver; (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; (4) Consult the dealer or an experienced radio/TV technician for help.
Declaration of Conformity (FCC 96-208 & 95-19): Synapse Wireless, Inc. declares that the product name CSEN1 to which this declaration relates, meet the requirements specified by the Federal Communications Commission as detailed in the following specifications:

  • 15. hluti, B-kafli, fyrir búnað í B-flokki
  • FCC 96-208 eins og það á við um einkatölvur og jaðartæki í flokki B
  • Þessi vara hefur verið prófuð á ytri prófunarstofu sem er vottuð samkvæmt FCC reglum og hefur reynst uppfylla FCC, Part 15, losunarmörk. Kveikt er á skjölum file og fáanlegt hjá Synapse Wireless, Inc.

Ef FCC auðkenni einingarinnar inni í þessari vöruhlíf er ekki sýnilegt þegar það er sett upp í öðru tæki, þá verður utan á tækinu sem þessi vara er sett upp í einnig að birta merkimiða sem vísar til meðfylgjandi einingarinnar FCC auðkenni. Breytingar (FCC 15.21):
Breytingar eða breytingar á þessum búnaði sem ekki eru sérstaklega samþykktar af Synapse Wireless, Inc., geta ógilt heimild notanda til að nota þennan búnað.
Einkaleyfi – sýndarmerking kl https://www.synapsewireless.com/about/patents
Til að læra meira skaltu heimsækja: synapsewireless.com

VOTTANIR

Fyrirmynd CSEN1-H-W-ZHA (white enclosure) or CSEN1-H-G-ZHA (gray enclosure)
Inniheldur FCC auðkenni QOQ-GM240P
Inniheldur IC 5123A-GM240P
RoHS 3 2011/65/EU (2015/863)
ESB REACH (EB) nr. 1907/2006

DALI-2 löggiltur forritastjórnandi

Synapse - lógóSynapse CSEN1 Combo Sensor Controller - icon

 

Skjöl / auðlindir

Synapse CSEN1 Combo Sensor Controller [pdfUppsetningarleiðbeiningar
CSEN1-H-W-ZHA, CSEN1-H-G-ZHA, CSEN1 Combo Sensor Controller, CSEN1, Combo Sensor Controller, Sensor Controller, Controller

Heimildir

Skildu eftir athugasemd

Netfangið þitt verður ekki birt. Nauðsynlegir reitir eru merktir *